website http://www.lgservice.com LG LG Room Air Conditioner SERVICE MANUAL MODELS: AS-H076PB/D/M/WL1 AS-H096PB/D/M/WL1 AS-H126PA/B/D/M/S/WL1 AS-H126PA/B/D/M/S/WG1 LS-C126PB/D/M/W/K/QL1 LS-H076PB/D/M/WL1 LS-H096PA/B/D/M/S/WL1 LS-H126PA/B/D/M/S/WL1 LS-C096PB/D/ML1 LSNH096PBL1.ABLALTA LSNH096PSL1.APXALTA LSNH096PES1.ASMALTA LS-H121PDL2.AWDBLAT LS-H121P*L3 CAUTION • BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. • ONLY FOR AUTHORIZED SERVICE PERSONNEL. Air Conditioner Service Manual TABLE OF CONTENTS LG Model Name ...............................................................................................................................................3 Safety Precautions..........................................................................................................................................4 Dimensions .....................................................................................................................................................8 Symbols used in this Manual......................................................................................................................8 Indoor Unit..................................................................................................................................................8 Outdoor Unit...............................................................................................................................................9 Product Specifications ................................................................................................................................11 Installation .....................................................................................................................................................14 Select the Best Location .........................................................................................................................14 Piping Length and Elevation.....................................................................................................................14 Preparing Work for Installation .................................................................................................................15 Fixing the Indoor Unit ...............................................................................................................................16 Drill a Hole in the wall...............................................................................................................................16 Flaring Work.............................................................................................................................................17 Connecting the Pipings ............................................................................................................................18 Connecting the Cables to the Indoor Unit ................................................................................................21 Connecting the Cables to the Outdoor Unit..............................................................................................22 Checking the Drainage.............................................................................................................................23 Forming the Piping ...................................................................................................................................23 Air Purging ...............................................................................................................................................24 Air Purging with Vacuum Pump................................................................................................................24 Front Panel Assembly ..............................................................................................................................26 Test Running ............................................................................................................................................27 Operation ......................................................................................................................................................28 Function of Controls .................................................................................................................................28 Display Function.......................................................................................................................................35 Self-diagnosis Function............................................................................................................................36 Remote Control Operations......................................................................................................................37 Disassembly ..................................................................................................................................................38 Indoor Unit................................................................................................................................................38 Schematic Diagram.......................................................................................................................................40 Electric control Device..............................................................................................................................40 Wiring Diagram.........................................................................................................................................41 Components Location ..............................................................................................................................42 Troubleshooting Guide .................................................................................................................................44 Refrigeration Cycle Diagram ....................................................................................................................44 2-way, 3-way Valve ...................................................................................................................................45 Cycle Parts...............................................................................................................................................50 Electronic Parts ........................................................................................................................................51 Exploded View ..............................................................................................................................................58 Indoor Unit...............................................................................................................................................58 Outdoor Unit............................................................................................................................................59 Replacement Parts List ................................................................................................................................61 Indoor ......................................................................................................................................................61 Outdoor ....................................................................................................................................................67 2 Room Air Conditioner LG Model Name 2003~ 1 Code 1 2 - 3 Type 4 5 6 Code of Model Producing Center, Refrigerant A~Z 7 8 9 10 Meaning L: Chang-won R22 A: Chang-won R410A C: Chang-won R407C T: China U: China R410A V: Vietnam S: Out Sourcing N: India Z: Brazil D: Indonesia X: Mexico K: Turkey R22 E: Turkey R410A H: Thailand 2 Product Type A~Z S: Split Type Air Conditioner 3 Cooling/Heating/Inverter A~Z C: Cooling only H: Heat pump X: C/O + E/Heater Z: H/P + E/Heater 4, 5 Capacity 0~9 Cooling/Heating Capacity Ex. "09" → 9,000 Btu/h 6 Electric Range 1~9 A~Z 1: 115V/60Hz, 2: 220V/60Hz 3: 208-230V/60Hz 5: 200-220V/50Hz 6: 220-240V/50Hz 7: 110V, 50/60Hz 8: 380-415V/50Hz 9: 380-415V/60Hz 7 Chassis A~Z Name of Chassis of Unit Ex. LSP → SP Chassis 8 Look A~Z Look, Color (Artcool Model) 9 Function A~Z 10 Serial No. 1~9 V: AC Inverter C/O N: AC Inverter H/P Q: DC Inverter C/O W: DC Inverter H/P A: 220V, 50Hz, 3Phase B: 208~230V, 60Hz, 3Phase C: 575V, 50Hz, 3Phase D: 440~460, 60Hz, 3Phase E: 265V, 60Hz F: 200V, 50/60Hz Basic Basic+4Way Plasma Filter Plasma Filter+4 Way Tele+LCD Tele+LCD+Nano plasma+4Way Nano Plasma F+(A/changeove)+A/clean+Low A Nano Plasma F+(A/changeove)+A/clean+4way+Low A Tele+LED+4way Internet Plasma F+4Way+Oxy generator Nano Plasma F+(A/changeove)+A/clean Nano Plasma F+(A/changeove)+A/clean+4way Nano Plasma F+(A/changeove)+A/clean+PTC Nano Plasma F+(A/changeove)+Autoclean+4way+PTC Nano Plasma F+(A/changeove)+A/clean+4way+Low A+PTC Negative ION+A/Clean (Nano)Plasma+Negative ION+A/Clean 4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean Nano Plasma F+4Way+(A/changeove)+A/clean+Oxy generator 4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean+Oxy generator Dry Contact Wired Remocon A B C D E F G H I J K L M N P Q R S T U V W 8 LG Model Development Serial No. * ARTCOOL COLOR R Mirror W White B Blue D Wood M Metal C Cherry N A S Q K Walnut Gogh Sisley Quran Mecca Service Manual 3 Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. ■ Installation Always perform grounding. • Otherwise, it may cause electrical shock. Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit. Don’t use a power cord, a plug or a loose socket which is damaged. • Otherwise, it may cause a fire or electrical shock. Always install an air leakage breaker and a dedicated switching board. • If the electrical part cover of the • No installation may cause a fire and indoor unit and the service panel of electrical shock. the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc. For installation of the product, always contact the service center or a professional installation agency. • Otherwise, it may cause a fire, electrical shock, explosion or injury. Do not keep or use flammable gases or combustibles near the air conditioner. • Otherwise, it may cause a fire or the failure of product. x Wa Thinner 4 Room Air Conditioner Safety Precautions Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time. • It may cause injury or an accident. Do not disassemble or repair the product randomly. • It will cause a fire or electrical shock. Do not install the product at a place that ther is concern of falling down. • Otherwise, it may result in personal injury. ■ Operation Use caution when unpacking and installing. • Sharp edges may cause injury. Do not modify or extend the power cord randomly. • Otherwise, it may cause a fire or electrical shock. Do not share the outlet with other appliances. • It will cause an electric shock or a fire due to heat generation. Take care so that the power cord may not be pulled during operation. • Otherwise, it may cause a fire or electrical shock. Do not use the damaged power cord. • Otherwise, it may cause a fire or electrical shock. Unplug the unit if strange sounds, smell, or smoke comes from it. • Otherwise, it may cause electrical shock or a fire. Service Manual 5 Safety Precautions Keep the flames away. • Otherwise, it may cause a fire. Do not open the suction inlet of the indoor/outdoor unit during operation. • Otherwise, it may electrical shock and failure. Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands. • Otherwise, it may cause a fire or electrical shock. Do not allow water to run into electrical parts. • Otherwise, it may cause a fire and electrical shock. Never touch the metal parts of the unit when removing the filter. • Otherwise, it may cause the failure of • They are sharp and may cause machine or electrical shock. injury. Do not step on the indoor/outdoor unit and do not put anything on it. • It may cause an injury through dropping of the unit or falling down. When the product is submerged into water, always contact the service center. • Otherwise, it may cause a fire or electrical shock. 6 Room Air Conditioner Do not use the power cord near the heating tools. Do not place a heavy object on the power cord. • Otherwise, it may cause a fire or electrical shock. Take care so that children may not step on the outdoor unit. • Otherwise, children may be seriously injured due to falling down. Safety Precautions ■ Installation Install the drain hose to ensure that drain can be securely done. • Otherwise, it may cause water leakage. Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors. Always inspect gas leakage after the installation and repair of product. • Otherwise, it may cause dispute with the neighbors. • Otherwise, it may cause the failure of product. ■ Operation Keep level parallel in installing the product. • Otherwise, it may cause vibration or water leakage. Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. • The appearance of the air conditioner may deteriorate, change color, or develop surface flaws. Avoid excessive cooling and perform ventilation sometimes. • Otherwise, it may do harm to your health. When gas leaks, open the window for ventilation before operating the unit. • Otherwise, it may cause explosion, and a fire. x Wa Thinner Service Manual 7 Dimensions Dimensions Symbols used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. NOTICE This symbol indicates special notes. Indoor Unit Hanger Hole W D H Fix Hole Pipe Hole Model INDOOR UNIT Dimension W mm 570 H mm 568 D mm 137 8 Room Air Conditioner Dimensions Outdoor Unit L2 D L1 W H L3 L5 Gas side (3-way valve) L4 Liquid side (2-way valve) DIM MODEL unit 7K Models W mm 575 H mm 525 D mm 260 L1 mm 301 L2 mm 73 L3 mm 392 L4 mm 35 L5 mm 100 Service Manual 9 Dimensions L2 D L1 W H L3 L5 Gas side (3-way valve) L4 Liquid side (2-way valve) DIM MODEL unit 9K, 12K Models W mm 770 H mm 540 D mm 245 L1 mm 285 L2 mm 64 L3 mm 518 L4 mm 10 L5 mm 100 10 Room Air Conditioner Product Specifications Product Specifications Table-1 Model Name AS-H076PB/D/M/WL1 AS-H096PB/D/M/W/L1 Item Unit AS-H126PA/B/D/M/S/WL1 AS-H126PA/B/D/M/S/WG1 7500 9200 12000 7700 9400 12200 l/h 1 1.2 1.5 Ø, V, Hz 1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz 5.5 7 8.3 20 26 34 37 37 44 48 46 46 685 840 1099 705 860 1200 3 3.8 4.9 3.1 3.85 5.3 10.95 10.95 10.92 3.2 3.2 2.98 24 24 24 18 25.5 25.5 570 x 568 x 137 570 x 568 x 137 570 x 568 x 137 575 x 525 x 260 770 x 540 x 245 770 x 540 x 245 8.5 8.5 8.5 23 31 35 750(R410A) 870(R410A) 880(R410A) O O O L.C.D Wireless L.C.D Wireless L.C.D Wireless 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) Sleeping Operation O O O Drain Hose O O O 3*1.0mm2 + 2*0.75mm2 3*1.0mm2 + 2*0.75mm2 3*1.0mm2 + 2*0.75mm2 3*1.0mm2 3*1.0mm2 3*1.0mm2 Cooling Capacity Btu/h Heating Capacity Moisture Removal Power Source Indoor Air Circulation Outdoor Indoor Noise Level Outdoor Input m3/min Cooling Heating Running Cooling Current Heating E.E.R. Cooling C.O.P Heating dB (A)±3 W A Btu/hW Indoor Motor Output Dimensions (W x H x D) Outdoor W Indoor Outdoor mm Indoor Net. Weight Outdoor Refrigerant kg g Airflow Direction Control (Up & Down) Remocon Type Liquid Service Valve Gas Connecting Cable(p*mm2) Power Cord(p*mm2) inch(mm) Service Manual 11 Product Specifications Table-2 Model Name LS-H076PB/D/M/WL1 Item Unit LS-H096PA/B/D/M/S/WL1 LS-H126PA/B/D/M/S/WL1 LSNH096P*L1 7000 9000 11000 7300 9300 12500 l/h 1 1.2 1.4 Ø, V, Hz 1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz 5.5 7 8.7 20 26 26 37 35 42 48 46 46 700 940 1250 628 910 1220 3 4.1 5.8 2.9 4 5.5 10 9.57 8.80 3.4 3 3 24 24 24 18 25.5 25.5 570 x 568 x 137 570 x 568 x 137 570 x 568 x 137 575 x 525 x 260 770 x 540 x 245 770 x 540 x 245 9 8.5 8.5 23 31 33 690(R-22) 950(R-22) 800(R-22) O O O L.C.D Wireless L.C.D Wireless L.C.D Wireless 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) Sleeping Operation O O O Drain Hose O O O 3*1.0mm2 + 2*0.75mm2 3*1.0mm2 + 2*0.75mm2 3*1.0mm2 + 2*0.75mm2 3*1.0mm2 3*1.0mm2 3*1.0mm2 Cooling Capacity Btu/h Heating Capacity Moisture Removal Power Source Indoor Air Circulation Outdoor Indoor Noise Level Outdoor Input m3/min Cooling Heating Running Cooling Current Heating E.E.R. Cooling C.O.P Heating dB (A)±3 W A Btu/hW Indoor Motor Output Dimensions (W x H x D) Outdoor W Indoor Outdoor mm Indoor Net. Weight Outdoor Refrigerant kg g Airflow Direction Control (Up & Down) Remocon Type Liquid Service Valve Gas Connecting Cable(p*mm2) Power Cord(p*mm2) 12 Room Air Conditioner inch(mm) Product Specifications Table-3 Model Name Item LS-C096PB/D/ML1 11000 9000 12000 - - 12000 l/h 1.4 1.2 1.5 Ø, V, Hz 1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz 1Ø, 115V, 60Hz 8.7 7 9 26 26 27 40 38 44 46 46 46 1250 900 1150 - - 1170 5.8 4 10.1 - - 10.2 8.8 10 10.4 - - 3.0 24 7.8 24 25.5 18 27 570 x 568 x 137 570 x 568 x 137 570 x 568 x 137 770 x 540 x 245 564 x 252 x 265 770 x 540 x 245 8.5 8.5 9 33 23 32 980(R-22) 710(R-22) 810 O O O L.C.D Wireless L.C.D Wireless L.C.D Wireless 1/4 (6.35) 1/4 (6.35) 1/4(6.35) 1/2 (12.7) 3/8(9.52) 1/2(12.7) O O O Unit Cooling Capacity Btu/h Heating Capacity Moisture Removal Power Source Indoor Air Circulation Outdoor Outdoor Input m3/min Indoor Noise Level Cooling Heating Running Cooling Current Heating E.E.R. Cooling C.O.P Heating dB (A)±3 W A Btu/hW Indoor Motor Output Dimensions (W x H x D) Outdoor W Indoor Outdoor mm Indoor Net. Weight Outdoor Refrigerant kg g Airflow Direction Control (Up & Down) Remocon Type Liquid Service Valve Gas inch(mm) Sleeping Operation O Drain Hose Connecting Cable(p*mm2) Power Cord(p*mm2) LS-H121PDL2 LS-C126PB/D/M/W/K/Q1 O O 3*1.0mm + 2*0.75mm 3*1.0mm 3*1.0mm2 3*1.0mm2 2 LS-H121PDL3 2 2 3*1.0mm +12*0.75 mm2 2 3*1.0mm2 Service Manual 13 Installation Installation Selection of the Best Location Indoor unit • Do not have any heat or steam near the unit. • Select a place where there are no obstacles in front of the unit. • Make sure that condensation drainage can be conveniently routed away. Do not install near a doorway. • Ensure that the space around the left and right of the unit is more than 50cm. The unit should be installed as high on the wall as possible, allowing a minimum of 10cm from ceiling. • Use a stud finder to locate studs to prevent unnecessary damage to the wall. More than 10cm More than 50cm More than 60cm More than 10cm More than 10cm More than 60cm More than 70cm Piping Length and Elevation Capacity (Btu/h) 5k~14k 18k~28k 30k~38k Standard Max. Length Elevation (m) B (m) Pipe Size Max. Length A (m) Additional Refrigerant (g/m) 20 GAS LIQUID 3/8"(Ø9.52) 1/4"(Ø6.35) 4 or 7.5 7 15 1/2"(Ø12.7) 1/4"(Ø6.35) 4 or 7.5 7 15 20 1/2"(Ø12.7) 1/4"(Ø6.35) 4 or 7.5 15 30 20 5/8"(Ø15.88) 1/4"(Ø6.35) 4 or 7.5 15 30 20 5/8"(Ø15.88) 3/8"(Ø9.52) 4 or 7.5 15 30 30 5/8"(Ø15.88) 3/8"(Ø9.52) 7.5 15 30 30 3/4"(Ø19.05) 3/8"(Ø9.52) 7.5 15 30 50 More than 50cm A CAUTION: Install the indoor unit on the wall where the height from the floor is more than 2 meter. Outdoor unit • If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted. • Ensure that the space around the back and sides is more than 10cm. The front of the unit should have more than 70cm of space. • Do not place animals and plants in the path of the warm air. • Take the air conditioner weight into account and select a place where noise and vibration are minimum. • Select a place so that the warm air and noise from the air conditioner do not disturb neighbors. Indoor unit Outdoor unit More than 2m Indoor unit A B B Outdoor unit Outdoor unit Oil trap A Indoor unit B If the piping length is more than 5m CAUTION: • Capacity is based on standard length and maximum allowance length is on the basis of reliability. • Oil trap should be installed every 5~7 meters. 14 Room Air Conditioner I Installation Preparing Work for Installation Open front panel 1. Push the front panel backward and lift it up to remove the two screws. 2. As soon as you lift the both lower parts of panel front, you can hear the sound from panel front. At this moment panel front is separated 3. After pulling down this panel a bit, separate connecting wire from the product. Panel Front Connector Remove pipe cover and side cover 1. Remove two screws(for fixing pipe cover) 2. Pull up the side cover of desired connecting direction, and then side cover is separated. 3. Pick the pipe hole of the side cover. CAUTION: After removing the pipe hole, cut the burr for safety. Pipe hole Side cover NOTICE When making pipe path through rear wall, you don’t need to pick the pipe hole. Drain hose junction 1. Remove the rubber stopple in the desired drain direction. 2. Insert drain hose into the handle of drain pan, and join drain hose and connecting hose according to the figure by. Adhesive Connecting part Drain hose Only the desired direction rubber cap Service Manual 15 Installation Fixing the Indoor Unit 1. Attach an Installation guide map on the desired surface. INSTALLATION GUIDE MAP 6. Look at suited horizon by horizontal meter on the horizontal setting line, and fix lightly the map by adhesive tape. Horizontality 2. Make a hole with a diameter of 6mm and depth of 30-35mm by piercing a screw point. IN ST AII AT IO N IN ST AL LA TIO N GU ID EM AP 7. Drill the pierted part as a diameter of 50mm for connecting piping. (In case of piercing rear surface) GU ID EM AP 3. Drive the fore plastic anchors into drilled points. IN ST AL LA TIO N GU ID EM AP Plastic anchors 4. Hang the hole of product at the upper screws, and remove the map. (Falling attention) INS TAL LAT ION GUID EM AP 8. First, Drive the two points of the upper parts by screws. (Leave 10mm for hanging the product) mm 10 IN ST AL LA TIO N GU 9. Drive the lower parts after facing the hole of product with plastic anchors, and fix completely the upper screws. Plastic anchors Hanger hole (Rear side of the product) 5. Check the fixed product with light power. 10. In case of nothing wrong, connect the pipe and the wire. (Refer to installation manual) Drill a Hole in the Wall WALL Outdoor 16 Room Air Conditioner (0.2~0.3") Indoor 5-7mm • Drill the piping hole with a ø50mm hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side. Installation Flaring Work Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure. Cutting the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally. Copper pipe Slanted Uneven Rough 90° 2. Measure the distance between the indoor and the outdoor unit. 3. Cut the pipes a little longer than measured distance. 4. Cut the cable 1.5m longer than the pipe length. Removing burrs Pipe 1. Completely remove all burrs from the cut cross section of pipe/tube. Reamer 2. Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing. Point down Flare nut Putting nut on • Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal. (not possible to put them on after flaring work) Copper tube Flaring work 2. Carry out flaring work with the flaring tool. Outside diameter mm inch Ø6.35 1/4 Ø9.52 3/8 Ø12.7 1/2 Ø15.88 5/8 Ø19.05 3/4 A mm 0~0.5 0~0.5 0~0.5 0~1.0 1.0~1.3 Bar Handle "A" 1. Firmly hold copper pipe in a die in the dimension shown in the table below. Bar Yoke Cone Copper pipe Clamp handle Red arrow mark Service Manual 17 Installation Check Smooth all round 1. Compare the flared work with the figure by. Inside is shiny without scratches 2. If a flared section is defective, cut it off and do flaring work again. = Improper flaring = Inclined Surface Cracked Uneven damaged thickness Even length all round Connecting the Pipings Indoor Preparing the indoor unit's piping and drain hose for installation through the wall. Route the indoor tubing and the drain hose in the direction of rear left or right Drain hose Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Loop Connecting cable Gas side piping Liquid side piping Drain hose NOTICE If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended. 18 Room Air Conditioner Installation Connecting the pipings with the indoor unit and drain hose with drain pipe 1. Align the center of the pipings and sufficiently tighten the flare nut by hand. Indoor unit tubing Flare nut Pipes 2. Tighten the flare nut with a wrench. Outside diameter mm inch Ø6.35 1/4 Ø9.52 3/8 Ø12.7 1/2 Ø15.88 5/8 Ø19.05 3/4 Torque kg.m 1.8 4.2 5.5 6.6 6.6 Open-end wrench (fixed) Flare nut Connection pipe Wrench Indoor unit tubing 3. When extending the drain hose at the indoor unit, install the drain pipe. Drain hose Indoor unit drain hose Adhesive Wrap the insulation material around the connecting portion. Vinyl tape (narrow) Plastic bands Insulation material 1. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there may be no gap. 2. Wrap the area which accommodates the rear piping housing section with vinyl tape. Indoor unit pipe Connection pipe Vinyl tape Wrap with vinyl tape (wide) Connecting cable Pipe 3. Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section. Vinyl tape(narrow) Wrap with vinyl tape Pipe Vinyl tape(wide) Drain hose Service Manual 19 Installation Outdoor Align the center of the pipings and sufficiently tighten the flare nut by hand. Finally, tighten the flare nut with torque wrench until the wrench clicks. • When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. Outside diameter mm inch Ø6.35 1/4 Ø9.52 3/8 Ø12.7 1/2 Ø15.88 5/8 Ø19.05 3/4 20 Room Air Conditioner Torque kg.m 1.8 4.2 5.5 6.6 6.6 Outdoor unit Gas side piping (Bigger diameter) Liquid side piping (Smaller diameter) Torque wrench Installation Connecting the Cables to the Indoor Unit. • Connect the cables to the indoor unit by connecting the wires to the terminals on the control board dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of the indoor unit.) • Before connecting the cables to the terminal block, remove the cables in the holder of the control cover and do it. CAUTION: • The above circuit diagram is subject to change without notice. • The earth wire should be longer than the common wires. • When installing, refer to the circuit diagram behind the panel front of the indoor unit. • Connect the wires firmly so that they may not be pulled out easily. • Connect the wires according to color codes, referring to the wiring diagram. CAUTION: If a power plug is not used, provide a circuit breaker between power source and the unit as shown by. Main power source Air Conditioner Circuit Breaker Use a circuit breake or time delay fuse. CAUTION: The power cord connected to the "A" unit should be selected according to the following specifications(Type "B" approved by HAR or SAA). (mm2) Grade NORMAL CROSS 5k~9k -SECTIONAL AREA 0.75 Unit(A) Indoor 12k 14k~18k 24k~28k 30k, 32k 36k, 38k 1.0 1.5 Indoor Indoor 2.5 2.5 5.5 Indoor Outdoor Outdoor Cable Type(B) H05VV-F H05VV-F H05VV-F H05VV-F H05RN-F H05RN-F The power connecting cable connecting the indoor and outdoor unit should be selected according to the following specifications (Type "B" approved by HAR or SAA). (mm2) NORMAL CROSS -SECTIONAL AREA Grade NORMAL CROSS-SECTIONAL AREA 0.75mm2 (mm2) 5k~12K 14k~18k 24k~28k 1.0 1.5 2.5 Grade NORMAL CROSS 30k, 32k 36k, 38k -SECTIONAL AREA 0.75 0.75 H07RN-F H07RN-F Cable Type(B) H07RN-F H07RN-F Cable Type(B) H07RN-F Service Manual 21 Installation Connecting the Cables to the Outdoor Unit 1. Remove the control cover from the unit by loosening the screw. Connect the wires to the terminals on the control board individually. Outdoor Unit Terminal block 2. Secure the cable onto the control board with the cord clamp. 3. Refix the control cover to the original position with the screw. Over 5mm Connecting cable Connecting cable 4. Use a recognized circuit breaker "A" between the power source and the unit. A disconnecting device to adequately disconnect all supply lines must be fitted. Circuit Breaker (A) Cover control Grade 5K~14K 18K 15 20 24k~28K 30k,32K 36k,38k 30 30 40 CAUTION: After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3) Specification of power source. 4) Confirm that electrical capacity is sufficient. 5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6) Confirm that the cable thickness is as specified in the power source specification. (Particularly note the relation between cable length and thickness. (Refer to page 21) 7) Always install an earth leakage circuit breaker in a wet or moist area. 8) The following would be caused by voltage drop. • Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload. 9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors. 22 Room Air Conditioner Installation Checking the Drainage Forming the Piping 1. Checking the drainage. • Pour a glass of water on the evaporator. • Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 1. Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes. • If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. 2. In cases whe
© Copyright 2024