ProBP 3400 tab 2 | OpenTopic | TOC Contents ProBP 3400 tab ...............................................................................................................................................3 Managed devices ............................................................................................................................................4 ProBP3400 error codes ...................................................................................................................................5 ProBP 3400 calibration and verification setup ...............................................................................................8 Calibrate and verify the device .....................................................................................................................10 Configure tab ................................................................................................................................................11 OpenTopic | ProBP 3400 tab | 3 ProBP 3400 tab The ProBP 3400 tab is the single access point to all device information and actions that you may perform on a ProBP 3400 (except product license installations – see Install a license for details. It is divided into two main areas: a general device information pane and a secondary tabbed pane. General device information pane The general device information pane shows device identification, location information, and communication addresses. The area may also contain special controls for actions to perform on the device. To align the ProBP 3400 date and time with the PC date and time, click Synchronize. Device information tab The device information tab displays the configuration of the device, including installed modules, installed firmware, and hardware versions. The battery does not have a firmware version. The manufactured date is determined from the serial number. Directly under the configuration information, two panes display warranty and repair information for the device. Click on a row to select it. Additional product specific information for the selected module displays in the detail pane to the right. Refer to the specific device help file within the Welch Allyn Service Tool. Upgrade tab The Upgrade tab lists the device module’s current firmware version number, and identifies modules with firmware available for upgrade. Select a module, and then click Upgrade or select the main device, and then click Upgrade All to install available firmware to your product. Follow onscreen instructions to complete the upgrade process. While the firmware is upgrading, the Welch Allyn Service Tool application displays a progress indicator. During the upgrade process the ProBP 3400 powers on and off. This is normal. You cannot perform other functions until the upgrade is complete. 4 | OpenTopic | Managed devices Managed devices Welch Allyn Service Tool provides features that can help you manage and maintain your inventory of supported Welch Allyn products. The Welch Allyn Service Tool install connects directly to Welch Allyn Customer Service. This system automatically receives firmware updates and feature upgrades for your supported products. Maintained device list Managing your product inventory begins with establishing your offline device list. After you add a device to this list, it is registered with the Welch Allyn Service Tool. Select Administration > Maintained devices from the Welch Allyn Service Tool menu bar to edit your Maintained device list. The dialog shows your current list of offline devices and a list of all devices currently online with the Welch Allyn Service Tool. Select a device from the Connected devices pane and click Add to Maintained Devices. You may remove a device from your Maintained device list by selecting it from the Maintained devices pane and clicking Delete. Once you add a device to the Maintained device list, you may receive work orders for that device on your work list. Work list The work list provides information about service actions – referred to as work orders - that are waiting for you to perform on your Maintained devices. Work orders may include periodic calibrations, upgrades, or license installations. To complete an open work order, connect the device requiring service to Welch Allyn Service Tool and perform the required action as you normally would. The Welch Allyn Service Tool automatically downloads updates for Connected devices. Click Request Work Orders to query for any updates available for your Maintained devices. Any available updates display in your work list. Install a license When you purchase a licensed upgrade for Welch Allyn Service Tool or a supported product you receive an authorization code from Welch Allyn Customer Service. This code enables you to activate the new feature(s) through the Welch Allyn Service Tool Install License feature. Select Administration > Install license from the Welch Allyn Service Tool menu bar to begin. Select Service tool license or Medical device license, enter your authorization code, and click Activate. If the selected device is online, your license activates immediately. If the selected device is not online, the license activates for later installation to the device and a license installation action is available on your work list. If there is any error in the activation process, confirm that you entered the correct authorization code, check your internet connection, and try again. If you cannot clear the problem, contact Welch Allyn Technical Support for assistance. Device recovery In an unlikely event, a supported device may fail and is unable to boot its operating firmware. Reasons for such a failure may include device memory errors or an interrupted device upgrade, among other possible causes. If this happens the device may display on your device list as a “Platform Bootloader” device. Welch Allyn Service Tool includes a plug-in for the Platform Bootloader device. The plug-in allows a Welch Allyn service technician to attempt device recovery by reinstalling the device firmware. Contact Welch Allyn Technical Support for assistance if device recovery is needed. OpenTopic | ProBP3400 error codes | 5 ProBP3400 error codes The following tables list the error messages associated with the Welch Allyn ProBP 3400. Error code Related System Additional details 000000001 Persistent storage error EERPOM is corrupt or invalid 000000001 BP module failure Mod F NIBP board failure Error condition Definition / Description Required action Low battery 5 minutes remaining. The battery is extremely low. Initial Click the OK button to dismiss the alarm condition occurs when 5 message. minutes of battery power remain; this Plug the device into the outlet to is the second low battery alarm. dismiss the message. Low battery 30 minutes remaining. The battery is extremely low. Initial Click the OK button to dismiss the alarm condition occurs when 30 message. minutes of battery power remain; this Plug the device into the outlet to is the first low battery alarm. dismiss the message. Powering down. Call for service. This message could be caused by various internal errors, power manager, and battery faults. The device will auto power off. Battery is absent or faulty. Battery is absent or faulty. Plug the device into the outlet to dismiss the message. User cancelled NIBP reading. Blood pressure reading cancelled by user. Retake measurement. Inflation too quick; check NIBP cuff and tubing connections. The blood pressure cuff inflated too quickly. Check for kinked hose. Cuff pressure limits exceeded. Powering down. Overpressure. Exceeded maximum limit for this patient mode. Limit patient movement. NIBP air leak; check cuff and tubing connections. Major air leak. Check connections (device will power down). Unable to determine NIBP; check Excessive patient movement. connections; limit patient movement. Call Welch Allyn service. NIBP not functional. Call for service. Auto zero failure. Unable to determine NIBP; check inflation settings. Could not reach target pressure. Check for air leaks. Incorrect NIBP cuff size. Check patient type. The patient is outside of the module's Retake measurement. capability to measure NIBP. Inflation too quick. Check NIBP cuff Inflation was too quick; check for a and tubing connections. kinked hose. Take corrective action; retake measurement. Unable to determine NIBP. Check inflation settings. Retake measurement. Reading couldn’t be obtained because a high enough inflation couldn’t be reached. 6 | OpenTopic | ProBP3400 error codes Error condition Definition / Description Required action Set date and time. Either date or time not set at all or data has not been set. Set date and time. Ambient temperature outside Device outside operating temperature An alarm will sound, but you may operating range. Retry measurement. range. continue to take measurements. Maximum number of patient records saved. Oldest record overwritten. The maximum number of test records An alarm will sound and are stored in memory and save is automatically overwrite oldest record attempted. with new record. You can prevent alarm from activating for subsequent saves by deleting them patient records from the Review tab. Data did not transfer. Data transfer unsuccessful with save. Try to transfer data again. Unable to save. Unable to save data/readings to device. Try to save data again. Low battery plug into outlet. The monitor’s battery voltage is too low to support printing. Connect the AC power adapter to recharge the battery. Unable to load configuration. Unable to load non-critical configuration item(s) from NAND Flash. Device will use engineering and factory defaults. Bluetooth connection was lost. The Bluetooth radio no longer has a connection with the target device. Exit the target application. Powerdown and restart the ProBP 3400. Relaunch the target application. Ensure that the ProBP 3400 is within 15 feet of the target device. Refer to operating system or computer hardware manuals of the target device for further troubleshooting. Bluetooth radio not functional. Call for service. Functional error. Call for service. Device should not be used and sent for repair. Unable to load critical configuration item(s) from NAND Flash. USB communication failure. Call for This message could be caused service. because an internal or external device connected but failed enumeration or an overcurrent condition on internal or external port could have occurred. User cancelled NIBP reading. Device should not be used and sent for repair. Disable the missing functionality with warning to user. Recovery from error may be possible with power cycle. Blood pressure reading was cancelled Click the OK button to dismiss the by the user. message. Retake NIBP. Excessive patient movement. NIBP reading is available, yet not Click the OK button to dismiss the precise due to movement, noise. message. Dubious reading will be accompanied Retake NIBP. by splat (*). OpenTopic | ProBP3400 error codes | 7 Error condition Definition / Description Required action Device is operating in battery mode. AC power cord has been disconnected. Click the OK button to dismiss the message. Plug the device into the outlet to dismiss the message. Powering down. Device is performing normal shutdown activities. System error; disconnect patient cables, power down, and restart. System failure: fault is detected that could adversely affect the product. Data did not transfer. Data transfer unsuccessful with send. Click the OK button to dismiss the message. Data transfer successful. Successful data transfer with automatic or manual save User must turn the VSM off using the On/Off button. Click the OK button to dismiss the message. 8 | OpenTopic | ProBP 3400 calibration and verification setup ProBP 3400 calibration and verification setup Test equipment part numbers The equipment detailed in the table below are used for ProBP 3400 calibration and verification. Contact Welch Allyn Customer Service to purchase or locate specific parts. Part number Description Quantity BP Y-tube, no fittings, 1/8 tube 1 4500-925 USB 2.0/5-pin Mini-B cable, gold, 6 feet 1 715701 Service test box 1 200-21000IN Pressure meter, Netech 1 401028 BP test volume repair fixture 1 OTS item BP T-tube, no fittings, 1/8 tube 1 97S775 Bulb, large, with air release valve 1 Dual lumina cuff end connector 1 Single lumina cuff end connector 1 1/8 tube 1 Setup OpenTopic | ProBP 3400 calibration and verification setup | 9 1. Connect a USB cable to the service test box; connect the opposite end to a PC. 2. Connect a mini B USB cable to the ProBP 3400 and the opposite end to the service test box. 3. Connect the blood pressure hose to the NIBP module and the test volume. • • • • Connect a piece of tubing to the squeeze bulb with bleeding screw; connect the opposite end to the square fitting connector. Connect another piece of tubing to the square fitting connector; connect the opposite end to the calibrated pressure meter. Connect another piece of tubing to the square fitting connector; connect the opposite end to the test volume. Connect the last piece of tubing to the square fitting connector; connect the opposite end to the "Y" fitting on the two-tube blood pressure connector. 10 | OpenTopic | Calibrate and verify the device Calibrate and verify the device 1. Click within the device row, then click Perform All to activate the test sequence for the module. 2. Enter information about any replacement parts used during service of the product. After entering the part information, click Begin to start the tests. 3. Follow the onscreen prompts in the right side pane of the test window to progress through the test sequence. The left pane shows the order of the required tests and tracks the test sequence progress. As the Welch Allyn Service Tool application completes each test, the pass/fail indicator changes to green for pass or red for fail, and the application proceeds to the next test. 4. To terminate the active test sequence at any time, click Abort. To terminate all tests, click Abort All. After the Welch Allyn Service Tool application completes all the tests, it displays the pass/fail test results. After you have finished reviewing the test results, click Close. On the Device information tab, the Welch Allyn Service Tool updates to the last successful date that calibration was performed. The only way to change the last calibrate date of service is to perform all tests and all tests pass. Any test failure will not change the calibration date. To see the updated calibration date, close the device tab and reopen. OpenTopic | Configure tab | 11 Configure tab The configure tab enables all users the option to change the location ID and the asset tag number. Additionally, users may configure the ProBP 3400 to: • • • • • Enable or disable the device to emulate Spot Vitals Signs LXi. Set the time limit before entering standby mode due to inactivity. Set the time limit before powering off due to inactivity. Enable or disable serial emulation (Bluetooth default setting). Set the Bluetooth radio time limit for searching for paired partner and active. Changing the current device configuration requires a Welch Allyn Gold license and a Biomed log in. You must update the device serial number when you replace the main board within the device. To update the device serial number: 1. Select the device tab, the configure tab, the Serial number tab, and click Change. 2. Enter the serial number from main circuit board as the Host Controller serial number. The serial number of the main board is located on the board. The device serial number is located on the bottom of the device and you must program the main board with this serial number.
© Copyright 2024