DATASHEET FOR SOLAR MONITORED INVERTER (SMI) 1/1 -10KW 10 KW Solar Monitored Inverter (SMI) Brief SMI series online Solar Monitored Inverter (SMI), a fully intelligent digital Solar Monitored Inverter (SMI), highly combines the latest controller and the most advanced software. It takes the sixth generation low-exhaust and big-power IGBT and static switch as power devices. This kind of Solar Monitored Inverter (SMI) is a perfect production of Baykee. It adopts the digital controlling technology, of which the core is high-speed on-line programmed microprocessor. Application Apply to Computer center, Network management center, Communication system, Automatic control system, ATM; Precision instrument and equipment, household appliances etc. widely apply to Home, Industrial. Feature: Pure sine wave output, true on-line dual conversion design Adopt 4 layer PCB, and SMD technology. High efficiency IGBT (Insulated Gate Bipolar Transistor) inverter technology the sixth generation low-exhaust and big-power IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power. The sixth generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability. Touch screen display, with the simple operation and Intuitive data. Set the work mode on the display directly, INVERTER mode, ECO mode, EPS mode. Intelligent detecting function - this system microprocessor can continually online detect power status, the breaker status and all the working status of the circuit. Excellent load feature - It is completely capable to load from 0-100% while no need to change to bypass, which make sure the output reliable. Cold start - When mains failure, can directly use the battery to start the inverter until the battery discharge to low voltage, when mains recover, can self-start Solar Monitored Inverter (SMI). Generator compatible - Solar Monitored Inverter (SMI) is compatible to the generator highly improves the generator input efficiency, save the energy. Intelligent communication - With RS232 and RS485 standard collocation, optional SNMP and dry contact Perfect protection - Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function. Selectable battery inspection module - can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator. High-powered dynamic feature - adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment, but also reduce the output voltage distortion. Input harmonic filter - effectively restrain the input THD, raise Solar Monitored Inverter (SMI), input power factor and reduce the input THD current. Working Principles of SMI: Technical Specification Model Power KW Working Principle Phase Max. DC Input Power Input ( PV Array, DC ) MPPT DC working Voltage range PV Numbers Max. DC Input Current Solar Charge Current Solar Charging Method Grid Input (AC) AC Charge Current Grid Input Voltage Range (MinMax) Output Voltage Stability Output Frequency Stability Crest Factor Output Waveform Distortion Degree Sine Wave, Linear Load < 3%; Non-Linear Load<5% Battery Input Voltage Range Maximum Battery Charging Current DC Rated Charging Current Battery Number Phase AC output Current (A) Max. AC output Current (A) Power Factor Nominal Voltage Inverter (Output) 180V-270V Maintenance Free Lead-acid Battery, Optional Lithium Battery 168-220v 20% of inverter capacity According to the battery capacity 16units 12V or 96units 2V batteries 1 phase 45.5 A 64 A For Resistive Load cosφ=1.0 and for inductive Load cosφ=0.9 220VAC, 230VAC, 240VAC,100VAC, 110VAC,120VAC ±1 %( Stable load); ±5%( fluctuant load) 50Hz 60Hz<±0.5% > 3:1 Battery Type Battery SMI 1/1 -10KW 10kW Pure sine wave on line 1-phase+N+G Standard: 15kw Optional: According to Customer demand 180-220 8 units standard 250w in a group Standard: 90A Optional: According to customer demand 20A (Standard), optional 20A~150A, Constant current, then constant voltage, charge with temperature compensation, automatic switch Between Equalized charge and Float charge 10A (Standard), optional 5A-30A Dynamic Characteristics Unbalance Load Voltage Instant voltage<±5%(from 0 to100% ), Instant recover time<10INV < ± 5% Overload Protection Bypass >96%(full load) Phase 1 Phase +N 220VAC, 230VAC, 240VAC,100VAC, 110VAC,120VAC 0ms(Adopted static switch ) Input voltage /frequency over limited protection Over current; short circuit ; factor low protection Voltage Input Protection Output Protection Battery Protection Over charge ; over-discharge protection Temperature Protection Environment over temperature protection; inverter over temperature protection Hardware Fault Protection Assistant power abnormal, breaker cut off ,breaker overload, power devices over current/over voltage etc protection Working Environment Temp: 0~40ºC, relative humidity 30%~ 90% ( 1% decrease against 100 meters’ rise. Altitude 4000m MAX) Cooling Down Method COMPULSIVE VENTILATION(with temperature control) Redundancy Function RS232/ RS485; optional SNMP card (for internet) Tandem hot backup or parallel connection Anti-surge Capacity 10/700μS,5KV ;8/20μS,20KA Protection Level IP21 Safety Performance Vin-n Vout-n 3000Vac, cree page<3.5mA , insulating resistance>2MΩ(500VDC) Noise (dB) 20~30 Dimension(W×D×H) mm 450 x 600 x 1200 Weight(Kg) 186 Communication Interface Systems Parameters Warranty 200% 1S Efficiency Transfer Time Protection Function 115% Normal Work, 125% 10 min, 150% 1 Min, Standard: 2 year, Optional:3/5 year
© Copyright 2024