Changes 4.0.3 vs 4.0.2 UK

CIRCUTOR,S.A.
Platform
PowerStudio 4.0.3
Changes 4.0.3 vs 4.0.2
Ver 1.0
Platform PowerStudio 4.0.3
Changes 4.0.3 vs 4.0.2
1. CORRECTION BUGS AND GENERAL IMPROVEMENTS ................................ 3
2. TASKS (Automatic sending reports) ........................................................... 3
3. Equipment.......................................................................................... 4
4. Environment HTML5 ............................................................................ 5
5. New DRIVERS ..................................................................................... 5
6. Others ............................................................................................... 5
2
Platform PowerStudio 4.0.3
1. CORRECTION BUGS AND GENERAL IMPROVEMENTS
•
Into the Java client, under the reporting environment, control "Go to" now works in
local time. Till now this control was performed in UTC
•
Updated the module sending emails, implementing new Windows libraries.
Increased the timeout to 10 seconds till next email sending
•
Optimized access to variables relatable, now blockages are avoided and it gains
fluency to access to these variables types
•
Fixed bug in the formula's debugger. "No valid formula" appears over the formula
field with a no apparent error. Also, when exporting the application with the option to
"Check Application", a lot of errors were displayed into the debugger list that are not
true
•
Access optimized to the configuration file of the exported and running application.
According casuistries the configuration file could become corrupted and the
PowerStudio service could be resetted
•
Optimized uninitialized management data. Applied filter to avoid recording data in
the DB, if the related equipment never have been communicated or initialized
•
Fixed issue of changing Modbus peripheral via PowerStudio. If the option
"communication with devices” was not selected, from the equipment selection
screen, it was not possible to change the peripheral number of the selected device
•
Optimization of downloading data from embedded PowerStudio to higher
PowerStudio engines, when there are data gaps into the DDBB due communication
failures of slave devices
•
solved bug with the size of fonts in the selection screen of variables, from remote
equipment, in the editor
2. TASKS (Automatic sending reports)
•
Implemented the version control in the "Tasks" tool.
•
Fixed the calculation of the start and end period of "WEEK"
3
Platform PowerStudio 4.0.3
3. Equipment
•
Solved bug in managing incremental energy meters variables produced by
occasional or temporary communication failures
•
Added the variable CT1INC to ReadWatt. Until this version, the team acquired
variable was the absolute value of the counter. Now you have the incremental
variable among records in databases and is available for reports, graphs and tables.
•
Added driver of CVM-C10 after a QNA500 that performs gateway functions
•
Fixed a bug in the
fundamental current
•
Fixed bug with the images of CEM (three versions)
•
Fixed bug with negative temperatures in the Computer Smart III.
•
Restored compatibility with CVM-1D prior to version 13 firmware. Previous versions
were incompatible with version 4.0.2 of PowerStudio and PowerStudio embedded
(EDS)
•
CVM-1D, added manual control of the digital output of device via the driver if the
equipment version supports it
•
Added the selection of the variable "ST" (protection status) in the RGU10RA driver
•
Solved error in the CIRWATT B driver that could prevent the discharge of certain
variables in the upper motor (AE, NAE, IE1Q, CE2Q, IE3Q, CE4Q)
•
Solved bug when updating firmware of equipment through the editor (now the new
version of the equipment is correctly updated in the archives of CFG settings).
•
Solved bug with the "flags" in the events driver that could prevent use certain
variables in some conditions
•
Solved bug when reading data from some DH96, Instant value , Maximum (peak)
and minimum (valley)
CVM-C10 driver that multiplied by
4
1000 the harmonic
Platform PowerStudio 4.0.3
4. Environment HTML5
• Solved error in the energies widget under the HTML5 PowerStudio HOME
SCREEN.
• Fixed Bug, error in monitoring display screens in real time
• Improved and optimized the X axis data in graphics visualization
• Filtering possible NULL data when it repaints the texts of the axes in the graphs.
Avoids wrong visualization of axis data
• Forced the refreshment of a conditional control on a SCADA screen if this is a image
5. New DRIVERS
•
CVM-B100
•
CVM-B150
•
Functional modules with PowerStudio
o
o
o
o
•
M-CVM-AB-8I-8OR
M-CVM-AB-8I-8OT
M-CVM-AB-8I-8OR
M-CVM-AB-Modbus/TCP Bridge
Detection for nonfunctional modules with PowerStudio
o
o
o
M-CVM-AB-MBUS
M-CVM-AB-LonWorks
M-CVM-AB-PROFIBUS
6. Others
•
Optimization viewing / updating the status of the variables in the OPC
Client driver.
•
Renewed license in OPC libraries
•
Improved system of internal logs. It is also now possible to access it from
the web browser, by requesting “http: // IP_PowerStudio: PORT / html /
log”
•
Update Signature JAVA Applet (Under Certificate COMODO)
5