Online datasheet

O N L I N E D ATA S H E E T
UM30-211118
UM30
ULTRASONIC SENSORS
UM30-211118 | UM30
ULTRASONIC SENSORS
A
B
C
D
E
F
Ordering information
Model name
Part no.
UM30-211118
6036921
Other models and accessories
www.sick.de/UM30
Detailed technical data
Performance
H
I
J
K
L
M
N
O
P
Q
R
S
T
Working range, limiting range
30 mm ... 250 mm, 350 mm
Resolution
≥ 0,18 mm
Repeatability
± 0,15 % 1)
Accuracy
± 1 % 1) 2)
Temperature compensation
✔
Response time
50 ms
Switching frequency
11 Hz
Output time
8 ms
Ultrasonic frequency (typical)
320 kHz
Detection area (typical)
See diagrams
Additional function
Set switching mode: Distance to object (DtO) / Window (Wnd) / Object between sensor and
background (ObSB), teach-in of switching output, set levels of switching outputs, switching output invertible, set on delay switching output, teach-in of analog output, scaling of analog outputs, invertible analog output, automatic selection of analog current or voltage output, temperature compensation, Multifunctional input: synchronization / multiplexing, synchronization
of up to 10 sensors, multiplexing: no cross talk of up to 10 sensors, set measurement filters:
value filter, filter strength, adjustable sensitivity, foreground suppression and detection area,
switch-off display, reset to factory default
Additional feature
3)
1)
2)
3)
Referring to current measurement value.
Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
Functions may vary depending on sensor type.
Interfaces
Analog output
1)
2)
3)
4)
5)
2
1 x 0 V ... 10 V (≥ 100 kΩ) 1) 1 x 4 mA ... 20 mA (≤ 500 Ω) 2) 1) 3)
Automatic selection of analog current or voltage output dependent on load.
For 4 mA ... 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
Output Q short-circuit protected.
PNP: HIGH = VS - (< 2 V) / LOW = 0 V.
DISTANCE SENSORS | SICK
Online data sheet | 2015-04-07 12:52:32
Subject to change without notice
UM30-211118 | UM30
ULTRASONIC SENSORS
Resolution analog output
12 bit
Switching output
1 x PNP (200 mA) 4) 5)
Multifunctional input (MF)
1 x MF
Hysteresis
3 mm
1)
2)
3)
4)
5)
Automatic selection of analog current or voltage output dependent on load.
For 4 mA ... 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
Output Q short-circuit protected.
PNP: HIGH = VS - (< 2 V) / LOW = 0 V.
Mechanics/electronics
Supply voltage Vs
DC 9 V ... 30 V 1) 2)
Power consumption
≤ 2,4 W 3)
Initialization time
< 300 ms
Design
Cylindrical
Housing material
Nickel-plated brass, PBT
Display: TPU
Ultrasonic transducer: polyurethane foam, glass epoxy resin
Connection type
Male connector, M12, 5-pin
Indication
LED display, 2 x LED
Weight
150 g
Sending axis
Straight
1)
2)
3)
Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
15 V ... 30 V when using analog voltage output.
Without load.
Ambient data
Enclosure rating
IP 67
Protection class
III
Ambient temperature
Operation: –25 °C ... +70 °C
Storage: –40 °C ... +85 °C
2015-04-07 12:52:32 | Online data sheet

Subject
to change without notice
DISTANCE SENSORS | SICK
3
UM30-211118 | UM30
ULTRASONIC SENSORS
Dimensional drawing (Dimensions in mm (inch))
UM30-211, UM30-212, UM30-213
84 (3.31)
51 (2.01)
M12 x 1
3
11 (0.43)
3
M30 x 1.5
A
B
C
D
E
F
1
2
5
5
(0.20)
(0.20)
① Connection
② Display
③ Mounting nuts, SW 36 mm
Connection type
H
I
J
K
L
M
N
O
P
Q
R
S
T
Connector M12, 5-pin
Connection diagram
UM30-21x118 Connector M12, 5-pin
brn
1
blk
4
blu
3
wht
2
gra
5
L+
Q/¯
Q
M
QA
Sync/Multi 1
① Synchronization and multiplex operation/communication Connect+
4
DISTANCE SENSORS | SICK
Online data sheet | 2015-04-07 12:52:32
Subject to change without notice
UM30-211118 | UM30
ULTRASONIC SENSORS
Adjustment possible
2
4
4
T1 D1 D2 T2
5
5
② Display
④ Control elements
⑤ Status indicators
Detection area
UM30-211
Detection area in mm (inch)
400
2
(15.75)
350
(13.78)
300
(11.81)
250
(9.84)
3
1
200
(7.87)
150
4
(5.91)
5
100
(3.94)
50
(1.97)
0
150
100
50
(5.91) (3.94) (1.97)
0
50
100 150
(1.97) (3.94) (5.91)
Detection area in mm (inch)
① Sensing range dependent on reflection properties, size and orientation of the object
② Limiting range
③ Working range
④ Example object: aligned plate 500 mm x 500 mm
⑤ Example object: pipe with 10 mm diameter
2015-04-07 12:52:32 | Online data sheet

Subject
to change without notice
DISTANCE SENSORS | SICK
5
UM30-211118 | UM30
ULTRASONIC SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Recommended accessories
Other models and accessories
www.sick.de/UM30
Brief description
Model name
Part no.
Mounting plate for M30 sensors, steel, zinc coated, without mounting hardware
BEF-WG-M30
5321871
Mounting bracket, M30 thread, steel, zinc coated, without mounting hardware
BEF-WN-M30
5308445
BEF-HA-M30A
5311527
Head A: female connector, M12, 5-pin, straight
Head B: Cable
Cable: PVC, unshielded, 2 m
DOL-1205-G02M
6008899
Head A: female connector, M12, 5-pin, angled
Head B: Cable
Cable: PVC, unshielded, 2 m
DOL-1205-W02M
6008900
Connect+
adapter (CPA)
6037782
Mounting brackets and mounting plates
Terminal and alignment brackets
Mounting bracket, M30, axial rotation possible, with threaded mounting hole M6, without mounting hardware
Plug connectors and cables
Programming and configuration tools
Tool for visualization, configuration and cloning, 3-digit LED display, supply voltage: DV
9 V ... 30 V
6
DISTANCE SENSORS | SICK
Online data sheet | 2015-04-07 12:52:32
Subject to change without notice
USmod 4c int43
Australia
Phone+61 3 9457 0600
1800 33 48 02 – tollfree
[email protected]
Belgium/Luxembourg
Phone +32 (0)2 466 55 66
E-Mail [email protected]
Brasil
Phone+55 11 3215-4900
E-Mail [email protected]
Canada
Phone+1 905 771 14 44
E-Mail [email protected]
Česká republika
Phone+420 2 57 91 18 50
E-Mail [email protected]
China
Phone +86 4000 121 000
[email protected]
Phone +852-2153 6300
[email protected]
Danmark
Phone+45 45 82 64 00
E-Mail [email protected]
Deutschland
Phone+49 211 5301-301
E-Mail [email protected]
España
Phone+34 93 480 31 00
E-Mail [email protected]
France
Phone+33 1 64 62 35 00
E-Mail [email protected]
Great Britain
Phone+44 (0)1727 831121
E-Mail [email protected]
India
Phone+91–22–4033 8333
E-Mail [email protected]
Israel
Phone+972-4-6801000
E-Mail [email protected]
Italia
Phone+39 02 27 43 41
E-Mail [email protected]
Japan
Phone+81 (0)3 5309 2112
E-Mail [email protected]
Magyarország
Phone+36 1 371 2680
E-Mail [email protected]
Nederland
Phone+31 (0)30 229 25 44
E-Mail [email protected]
SICK AG |Waldkirch|Germany|www.sick.com
Norge Phone+47 67 81 50 00
E-Mail [email protected]
Österreich
Phone+43 (0)22 36 62 28 8-0
E-Mail [email protected]
Polska
Phone+48 22 837 40 50
E-Mail [email protected]
România
Phone+40 356 171 120
[email protected]
Russia
Phone+7-495-775-05-30
E-Mail [email protected]
Schweiz
Phone+41 41 619 29 39
E-Mail [email protected]
Singapore
Phone+65 6744 3732
E-Mail [email protected]
Slovenija
Phone+386 (0)1-47 69 990
E-Mail [email protected]
South Africa
Phone+27 11 472 3733
E-Mail [email protected]
South Korea
Phone+82 2 786 6321/4
E-Mail [email protected]
Suomi
Phone+358-9-25 15 800
E-Mail [email protected]
Sverige
Phone+46 10 110 10 00
E-Mail [email protected]
Taiwan
Phone+886-2-2375-6288
E-Mail [email protected]
Türkiye
Phone+90 (216) 528 50 00
E-Mail [email protected]
United Arab Emirates
Phone+971 (0) 4 8865 878
E-Mail [email protected]
USA/México
Phone+1(952) 941-6780
1 800-325-7425 – tollfree
E-Mail [email protected]
More representatives and agencies