Certified Reference Material Address: 2710 S. Boulder Drive, Urbana, IL 61802 USA Email: [email protected] Tel:+1-217-359-2344; Fax: +1-217-351-8091 Certificate of Analysis AOCS 0411-C, non-modified maize powder Certified Property Certified Presence 5307 No Pure, non-modified maize Measurement Uncertainty Test Method NA event-specific realtime PCR Description: This is the first batch of non-modified maize CRM prepared by AOCS for Syngenta Biotechnology Inc. This material is for limited purposes only: see "Intended Use" and “Terms and Conditions.” This certificate is valid through: March 2016 This validity may be extended when further evidence of stability becomes available. Customers will be notified by AOCS if a stability issue arises at AOCS Headquarters. Introduced: 16 March 2015 AOCS Chief Science Officer AOCS Reference Materials Manager and Technical Director G. M. Clapper R. C. Cantrill Urbana, IL 61802 Urbana, IL 61802 AOCS Mission: AOCS advances the science and technology of oils, fats, surfactants and related materials, enriching the lives of people everywhere. Characterization Product Description AOCS 0411-C has been prepared by AOCS from maize devitalized seed. AOCS 0411-C is available in 27-mL glass headspace vials containing approximately 10 g of maize powder. Users are informed that this reference material has been produced from devitalized seed of nonmodified maize (NP2171 x NP2460) delivered by Syngenta Biotechnology Inc. Homogeneity Ten packaged samples, 10 g each, were tested using event-specific qualitative PCR methods developed and validated by Syngenta Biotechnology Inc. Test ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-C Page 1 of 4, © AOCS, 2015 results received from Eurofins-GeneScan, New Orlean, LA (an ISO 17025 accredited laboratory) for qualitative, event-specific analysis were entered into the SeedCalc8 program for Impurity Estimation & Confidence Intervals. The statistical analysis shows within 95 % confidence that the lower bound of true purity of AOCS 0411-C is < 1.0 g/kg 5307 in this non-modified maize. Stability AOCS Certified Reference Materials are tested for stability on an annual basis and certificates may be extended based on the outcome of this testing. Analytical Method Used for Certification Eurofins-GeneScan, New Orlean, LA (an ISO 17025 accredited laboratory) performed event-specific real-time PCR for 5307 to validate the certification value of AOCS 0411-C. Warnings and Precautions This product is for laboratory use only and is not for consumption. The user of this CRM should follow safety requirements and rules issued by voluntary organizations and government agencies expert in the field of laboratory safety. Intended Use This CRM, AOCS 0411-C, is intended for use as quality control material or calibrant in methods for the detection, identification, and/or quantification of biotechnology-derived events. Instructions for Use Upon receipt the product should be stored in a sealed container at +4° C in the dark. The product may have settled during shipment, therefore, thoroughly mix the CRM before use to insure homogeneity. Product opening date: _____________________________(completed by customer) Recommended test portion for DNA extraction: minimum of 1 g Protocols have been followed to insure that the certified presence represents the true presence. AOCS cannot be held responsible for changes that happen during storage of the product at the buyer’s location. ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-C Page 2 of 4, © AOCS, 2015 Note: The AOCS 0411-C Certification Report is available online though a paper copy will be supplied upon request. Terms and Conditions (i – ix) i. The CRM AOCS 0411-C shall be used solely 1) in assays for (a) detecting the presence of non-modified, or (b) quantification of nonmodified; or 2) for determining whether an assay cross-reacts with CRM AOCS 0411-C. CRM AOCS 0411-C shall be used for no other purpose. Specifically the CRM may not be used to develop a detection method for non-modified nor trait(s) present therein. No other rights are conveyed by the sale of the CRM 0411-C to any purchaser, including any rights to any pending or granted Syngenta Biotechnology Inc Patents or other Syngenta Biotechnology Inc Intellectual Property that may protect the CRM or non-modified or trait(s) present therein or a detection method for non-modified. ii. Neither the CRM AOCS 0411-C nor any extract or portion thereof shall be resold or redistributed by any purchaser, unless the resale or redistribution is required by national law in force in the purchaser’s country. iii. Neither the CRM AOCS 0411-C, nor any extract or portion thereof, shall be used for human or animal consumption or human or animal trials. iv. Neither the CRM AOCS 0411-C nor non-modified DNA, nor any part of either of these, shall be used for transformation or breeding. v. No characterization or derivation of non-modified, of the trait or traits present in CRM AOCS 0411-C, or of the CRM AOCS 0411-C shall be performed, except as allowed for in section (i). vi. All assay activities undertaken using the CRM AOCS 0411-C shall be conducted in strict compliance with all Applicable Laws governing such activities, and shall comply with conditions of all permits and authorizations which may be required for such activities; and such activities shall be strictly limited to assays in contained facilities, for example, laboratories. ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-C Page 3 of 4, © AOCS, 2015 vii. Prior to disposal of any used or excess CRM AOCS 0411-C or residues thereof, such material or residue must be treated in a manner that degrades non-modified in the CRM material, such as by autoclaving. viii. CRM AOCS 0411-C shall not be exported nor re-exported in violation of any Applicable Laws or without securing any necessary export or import clearances or permits. ix. THE CRM 0411-C IS PROVIDED FOR THE PURPOSES STATED HEREIN AND FOR NO OTHER PURPOSE. ALL CRM AOCS 0411-C AND Syngenta Biotechnology Inc MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED. Syngenta Biotechnology Inc MAKES NO REPRESENTATION OR WARRANTY THAT THE USE OF THE CRM AOCS 0411-C, WHETHER BEFORE, ON OR AFTER THE EFFECTIVE DATE OF THE APPLICABLE CERTIFICATE, WILL NOT INFRINGE ANY PATENT OR OTHER PROPRIETARY RIGHTS. ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-C Page 4 of 4, © AOCS, 2015 Certified Reference Material Address: 2710 S. Boulder Drive, Urbana, IL 61802 USA Email: [email protected] Tel:+1-217-359-2344; Fax: +1-217-351-8091 Certificate of Analysis AOCS 0411-D, 5307 maize powder Certified Property Certified Presence 5307 Yes Pure, Heterozygous 5307 maize Measurement Uncertainty Test Method NA event-specific realtime PCR Description: This is the first batch of 5307 maize CRM prepared by AOCS for Syngenta Biotechnology Inc. This material is for limited purposes only: see "Intended Use" and “Terms and Conditions.” This certificate is valid through: March 2016 This validity may be extended when further evidence of stability becomes available. Customers will be notified by AOCS if a stability issue arises at AOCS Headquarters. Introduced: 16 March 2015 AOCS Chief Science Officer AOCS Reference Materials Manager and Technical Director G. M. Clapper R. C. Cantrill Urbana, IL 61802 Urbana, IL 61802 AOCS Mission: AOCS advances the science and technology of oils, fats, surfactants and related materials, enriching the lives of people everywhere. Characterization Product Description AOCS 0411-D has been prepared by AOCS from maize devitalized seed. AOCS 0411-D is available in 27-mL glass headspace vials containing approximately 10 g of maize powder. Users are informed that this reference material has been produced from devitalized seed of 5307 maize ((NP2171 x NP2460 / 5307)) delivered by Syngenta Biotechnology Inc. Homogeneity Ten packaged samples, 10 g each, were tested using event-specific qualitative PCR methods developed and validated by Syngenta Biotechnology Inc. Test ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-D Page 1 of 4, © AOCS, 2015 results received from Eurofins-GeneScan, New Orlean, LA (an ISO 17025 accredited laboratory) for qualitative, event-specific analysis were entered into the SeedCalc8 program for Impurity Estimation & Confidence Intervals. The statistical analysis shows within 95 % confidence that the lower bound of true purity of AOCS 0411-D is > 998.8 g/kg 5307 maize. Stability AOCS Certified Reference Materials are tested for stability on an annual basis and certificates may be extended based on the outcome of this testing. Analytical Method Used for Certification Eurofins-GeneScan, New Orlean, LA (an ISO 17025 accredited laboratory) performed event-specific real-time PCR for 5307 to validate the certification value of AOCS 0411-D. Warnings and Precautions This product is for laboratory use only and is not for consumption. The user of this CRM should follow safety requirements and rules issued by voluntary organizations and government agencies expert in the field of laboratory safety. Intended Use This CRM, AOCS 0411-D, is intended for use as quality control material or calibrant in methods for the detection, identification, and/or quantification of biotechnology-derived events. Instructions for Use Upon receipt the product should be stored in a sealed container at +4° C in the dark. The product may have settled during shipment, therefore, thoroughly mix the CRM before use to insure homogeneity. Product opening date: _____________________________(completed by customer) Recommended test portion for DNA extraction: minimum of 1 g Protocols have been followed to insure that the certified presence represents the true presence. AOCS cannot be held responsible for changes that happen during storage of the product at the buyer’s location. ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-D Page 2 of 4, © AOCS, 2015 Note: The AOCS 0411-D Certification Report is available online though a paper copy will be supplied upon request. Terms and Conditions (i – ix) i. The CRM AOCS 0411-D shall be used solely 1) in assays for (a) detecting the presence of 5307, or (b) quantification of 5307; or 2) for determining whether an assay cross-reacts with CRM AOCS 0411-D. CRM AOCS 0411-D shall be used for no other purpose. Specifically the CRM may not be used to develop a detection method for 5307 nor trait(s) present therein. No other rights are conveyed by the sale of the CRM 0411-D to any purchaser, including any rights to any pending or granted Syngenta Biotechnology Inc Patents or other Syngenta Biotechnology Inc Intellectual Property that may protect the CRM or 5307 or trait(s) present therein or a detection method for 5307. ii. Neither the CRM AOCS 0411-D nor any extract or portion thereof shall be resold or redistributed by any purchaser, unless the resale or redistribution is required by national law in force in the purchaser’s country. iii. Neither the CRM AOCS 0411-D, nor any extract or portion thereof, shall be used for human or animal consumption or human or animal trials. iv. Neither the CRM AOCS 0411-D nor 5307 DNA, nor any part of either of these, shall be used for transformation or breeding. v. No characterization or derivation of 5307, of the trait or traits present in CRM AOCS 0411-D, or of the CRM AOCS 0411-D shall be performed, except as allowed for in section (i). vi. All assay activities undertaken using the CRM AOCS 0411-D shall be conducted in strict compliance with all Applicable Laws governing such activities, and shall comply with conditions of all permits and authorizations which may be required for such activities; and such activities shall be strictly limited to assays in contained facilities, for example, laboratories. vii. Prior to disposal of any used or excess CRM AOCS 0411-D or residues thereof, such material or residue must be treated in a manner that degrades 5307 in the CRM material, such as by autoclaving. ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-D Page 3 of 4, © AOCS, 2015 viii. CRM AOCS 0411-D shall not be exported nor re-exported in violation of any Applicable Laws or without securing any necessary export or import clearances or permits. ix. THE CRM 0411-D IS PROVIDED FOR THE PURPOSES STATED HEREIN AND FOR NO OTHER PURPOSE. ALL CRM AOCS 0411-D AND Syngenta Biotechnology Inc MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED. Syngenta Biotechnology Inc MAKES NO REPRESENTATION OR WARRANTY THAT THE USE OF THE CRM AOCS 0411-D, WHETHER BEFORE, ON OR AFTER THE EFFECTIVE DATE OF THE APPLICABLE CERTIFICATE, WILL NOT INFRINGE ANY PATENT OR OTHER PROPRIETARY RIGHTS. ISO Guide 34 A2LA Certificate 3438.01 Certificate of Analysis for 0411-D Page 4 of 4, © AOCS, 2015
© Copyright 2024