GOVERNMENT OF INDIA DEPARTMENT OF ATOMIC ENERGY DIRECTORATE OF CONSTRUCTION, SERVICES AND ESTATE MANAGEMENT CHIEF PROJECT ENGINEER (MECHANICAL) 4th floor, Vikram Sarabhai Bhavan, Anushaktinagar, Mumbai – 400 094 e-Tender - FINANCIAL BID NIT No.: DCSE/CPE (M)/Telephone/AMC/47/13-2014 dt. 10/06/2013 SCHEDULE OF QUANTITY Name of work :- Rennovation/upgradation and biennial maintenance contract for telephone network system under DCSEM at Anushaktinagar,Mumbai -400094 NAME OF THE CONTRACTOR Sl. No. 1 2 2.1 2.1.1 2.1.2 2.1.3 2.1.4 2.1.5 2.1.6 2.1.7 2.2 Description Qty. Unit Rate Preventive, breakdown maintenance of telephone network as per Clause No:- 1 of additional technical specification. (refer technical bid). Job/qtr Supply installation, testing & commissioning of the following : Terminal boxes, telephone chords etc. RJ-11 telephone socket of model no. 6745 21 (Mosaic) of M/s Legrand make. each 50 White cover plate 1-module model no. 6745 51 (Mosaic) of M/s Legrand make White cover plate 2-module model no. 6745 51 (Mosaic) of M/s Legrand make each each 25 10 Plastic surface box 1/2 module 6745 46A (white colour) of M/s Legrand make each Coiled telephone chord (approx. 0.5m) with RJ-11 connectors crimped at both ends including interconnection of the same with the base unit & handset. each Single pair telephone chord (approx. 2m) with RJ-11 connectors crimped at both ends including interconnection of the same with the telephone connector box & telephone instrument. each 50 Telephone connector box with one no of RJ-11 telephone socket Analog telephone instrument with caller ID facility Panasonic KX-TSC62SX model or superior model or equivalent make and model of Alcatel/Avaya/Tadiran Note : i) All instruments supplied must be guaranteed & maintained free of cost till the completion of contract. Defective instruments must be replaced with new instruments wherever required. ii) Stock of 10 analog instruments shall be maintained through out the contract period. Amount in Rs. 0 8 0 0 0 0 0 100 0 100 each 100 each 200 0 0 Page 1 of 4 Sl. No. Description 2.3 Disconnection modules, ready made junction boxes etc. Note: 1) Scope includes dismantling of existing TTB/feeder pillar/disconnection module and retermination of existing cables, if required. 2) Existing CT box can be utilised with the approval of E-I-C, if in good condition . 2.3.1 10 pair disconnection module of M/s ADC Krone (Schneider) make part no. 6901100602 including dismantling the existing damaged 10 pair modules & re-termination of the wires on the new module. Qty. Unit Rate 0 each 50 2.3.2 10 x 10 pair disconnection modules of M/s ADC Krone (Schneider) make part no. 69001100602 along with acrylic covers, mounting arrangement & installation of the same in termination of wires.the existing MDF/TTB etc. including termination of wires. 2.3.3 2.3.3.1 2.3.3.2 2.3.3.3 2.3.3.4 2.3.3.5 2.3.3.6 2.3.4 0 each 10 Telephone junction box Telephone junction box of suitable size made out of MS CRCA sheet, powder coated, gasket and locking arrangement, having SS back mount frames, wherever required, etc.of complete with termination of wires etc. all as required & directed containing disconnection modules of M/s Krone make part no. 6901100602 with acrylic cover of the following sizes of Junction box make of M/s ADC Krone(Schneider)/ITL make complete with all mounting aceesories as required as per instructions of E-I-C: 0 each 6 each each each each each 6 4 4 2 2 100 pair Feeder Pillar box for external use made out of 3 mm thick MS CRCA sheet totally weather resistant, outdoor type, dust, water & rust proof, duly powder coated with rubber gasket on door, locking arrangement, weather proof canopy etc. of M/s ADC Krone(Schneider)/ITL make containing disconnection modules of M/s ADC Krone (Schneider) part no. 6901100602 with acrylic cover of the following sizes complete with all mounting aceesories including dismantlihg of existing feeder pillar and agle iron framework, welding, painting etc, if required, as per instructions of E-I-C: each 4 Telephone junction box 20 pair Telephone junction box 50 pair Telephone junction box 100 pair Telephone junction box 200 pair Telephone junction box 600 pair Amount in Rs. 0 0 0 0 0 0 2.4 Telephone wires 2.4.1 2 pair, pvc insulated, 0.5mm dia. annealed solid copper conductor telephone wires of M/s Delton / Finolex make in existing PVC casing capping / conduit/in open etc. 0 m 3000 Page 2 of 4 Sl. No. 2.5 2.5.1 2.5.1.1 2.5.1.2 2.5.1.3 2.5.1.4 2.5.2 2.5.2.1 2.5.2.2 2.5.2.3 2.5.2.4 2.6 2.6.1 2.6.1.1 2.6.1.2 2.6.1.3 2.6.1.4 Description Qty. Unit Rate Amount in Rs. Telephone cable 0.5 mm dia. annealed solid conductor, colour coded & twisted pair polyethylene insulated, PVC sheathed, fully jelly filled, GI wire/strip armoured telephone cable of the following sizes, in existing hume pipe / trench etc. /over surface with 4 mm thick hot dipped GI spacer and 16 SWG thick hot dipped GI saddles fixed at a distance of 350 mm from each other with screws and PVC phil plug etc. etc.minimum no. 10 x 35 mm GI wood screws etc. 10 pair m 300 0 0 20 pair m 50 pair m 100 pair m Same as in item no. 2.5.1 but in ground including earth excavation including soft rock 500mm wide and 600 mm deep complete with sand bedding and brick protection and refilling as required as per standards and instructions of E-I-C: Note: Measurement of hard rock excavation will be done separately. 300 300 150 10 pair 20 pair m m 300 500 50 pair m 200 0 0 100 pair m 150 0 0 0 0 0 Cable jointing, end termination etc. Providing straight joints for PJF armoured telephone cable with M/s Raychem make jointing kit complete with all accessories for cables of the following sizes. 10 pair each 6 20 pair each 6 50 pair each 4 0 0 100 pair each 4 0 10 pair each 20 0 20 pair each 20 0 50 pair each 10 0 100 pair each 6 0 2.6.2 End termination of PJF armoured telephone cable with M/s Raychem make end termination kit complete with sizes. 2.6.2.1 2.6.2.2 2.6.2.3 2.6.2.4 2.7 2.7.1 2.7.2 2.7.3 2.8 2.8.1 2.8.2 2.9 3 PVC casing capping (white) of following sizes on surface of slab / wall / column fixed with nylon rawal plug, GI wood screws at intervals of 300mm included providing the tags for wires inside casing capping for bunching to avoid hanging of wires at the intervals of 600mm. 0 25x16 mm m 200 38x25 mm m 20 0 50x50 mm m 20 0 m m m 100 200 150 G I Pipe 50mm dia Class B GI pipe laid in existing trench etc. with proper fixing / mounting. 50mm dia. Class B GI pipe fixed over the wall / surface etc. with GI clamp, coaches screws etc. 150mm dia. RCC Hume pipe laid in existing trench with wooden bushes etc Excavation 0 0 0 Page 3 of 4 Sl. No. 3.1 3.2 4 4.1 4.1.1 4.1.1.1 4.1.1.2 4.1.2 4.1.2.1 4.1.2.2 4.2 5 6 7 8 9 10 10.1 10.2 11 Description Qty. Cutting of Shahabad stone / footpath/ road cutting (of thickness upto 10 inches) including refilling / reinstatement of the excavated portion after completion of work, complete all as required. Sqm Excavation in hard rock/ PCC, including reinstatement of the excavated portion after completion of work, complete all as required. Cum Installation, testing & commissioning of the following departmental supplied cable / wires. Armoured PJF telephone cable 50 pair In exiting hume pipe / trench etc m Over the wall / surface with 4 mm thick hot dipped GI spacer and 16 SWG thick hot dipped GI saddles fixed at intervals of 350 mm from each other with minimum no. 10 x 35 mm GI wood screws and PVC phil plug etc. 100 pair In exiting hume pipe / trench etc Over the wall / surface with 4 mm thick hot dipped GI spacer and 16 SWG thick hot dipped GI saddles fixed at intervals of 350 mm from each other with minimum no. 10 x 35 mm GI wood screws and PVC phil plug etc. G.I. wire / PVC insulated aluminum wire Identification of the telephone nos. in existing MDF / TTB preparation of laminated chart indicating the telephone no, tag block no. etc. compete all as required & directed. Locating fault in 10P / 20P / 50P / 100P PJF armoured telephone cable laid in ground. Unit 0 50 150 m 50 m 150 m m 50 1000 4 10 Each Each 50 30 Supply and installation of cable marker embossed with “ DCSEM TELEPHONE CABLE” with 25/32 mm GI pipe. Each Painting with 2 coats of enamel paint of approved colour and labeling with black enamel paint all as per instructions of E-I-C Painting of existing TTB (indoor) Each Painting of existing Feeder pillar(outdoor) Each 20 Reparing of TTB/Fedder pillar doors by welding /providing new hinges in place of existing damaged /rusted hinges/reparing of PCC with all the required material. Each Amount in Rs. 0 250 Job Job Repairing of defective telephone instruments of various models of Beetel / Tata Fone etc. make & making it functional by repairing / replacing the defective part. Replacement of defective panel lock of TTB / FP with new panel lock. Rate 30 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 TOTAL TOTAL REBATE IN PERCENTAGE ( IF ANY) GRAND TOTAL AFTER REBATE 0.00 0.00 0.00 Page 4 of 4
© Copyright 2024