Online Monitoring of Steam Quality

Online Monitoring of Steam Quality
Steam turbines
To protect your steam turbine from potential damage from deposits and corrosion, MAN PrimeServ offers you an online analytical
system constantly monitoring the steam quality.
Strict compliance with the specified steam quality by using a suitable water treatment and
conditioning is fundamental for the avoidance of potential damage to the steam turbine
and the steam-carrying plant components. Even short-term operation of the steam turbine
unit outside the specified operating conditions can lead to significant impairment or damage due to deposits and corrosion.
Modernization Solution
To avoid damage to the steam turbine as a result of operation not in compliance with the
respective chemical mode of operation, MAN PrimeServ offers an analytical system con-
stantly monitoring the steam quality. Based on an industrial standard system, the monitoring system can be optimally adapted to the relevant plant and mode of operation due to
its modular design. Depending on the specific configuration, the steam monitoring system
enables the continuous monitoring of the steam parameters as:
n
Direct conductivity*
n
Degassed acid conductivity*
n
n
n
n
n
Acid conductivity*
pH value*
Silicic acid content
Sodium content
Further parameters on request
PS_Leaflet_4c_Master.indd 1
28.11.2014 11:06:07
Online Monitoring of Steam Quality
Steam turbines
able the direct display of the current measured values as well as the alarm notifications in
the event of threshold value violations in the monitoring system of the steam turbine unit.
In addition to this, the data can be transferred via the optional intelligent remote diagnostic
system irds® to MAN PrimeServ and used together with the other machine parameters for
condition analyses and maintenance planning support.
Benefits
The modernization solution facilitates continuous online monitoring of the specified steam
quality:
n
Protection from deposits of dissolved and undissolved substances in the steam
and gases dissolved in the steam
n
Protection from corrosion due to electrolytic deposits, potential differences, pH value
n
Direct display of measuring data in steam turbine control system
n
Provision of data via optional intelligent remote diagnostic system irds® for condition
n
Alerting of operating personnel in the case of non-conformities
monitoring and maintenance planning support
Comprehensive Modernization
MAN PrimeServ provides comprehensive modernization concepts to modernize your
equipment – no matter if you want to optimize reliability, operating costs, environmental
sustainability or anything else. Please contact us for further information.
* Basic configuration
PS_Leaflet_4c_Master.indd 2
All data provided in this document is non-binding. This data serves informational purposes only and is especially not warrented and/or guaranteed in any way. Depending on the specific individual projects, the relevant data may be subject to changes and will be assessed and
determined individually for each project. This will depend on the particular characteristics of each individual project, especially specific site and operational conditions · Copyright © MAN Diesel & Turbo · PLM.122014.3 · Printed in Germany
The measuring points can be integrated in the control system of the steam turbine to en-
MAN Diesel & Turbo
86224 Augsburg, Germany
Phone +49 821 322-0
Fax +49 821 322-3382
[email protected]
www.mandieselturbo.com