SITE MAP VICINITY MAP SITE SITE Elevator and Ramp Addition to: PHOENIX CENTER 291 LOCUST AVE. ANNAPOLIS, MD 21401 ASBESTOS VERIFICATION FORM for: DRAWING INDEX Anne Arundel County Public Schools Facilities Division 9034 Fort Smallwood Road Pasadena, MD 21122 T1.0 COVER SHEET ARCHITECTURAL STRUCTURAL A0.0 CODE REVIEW A0.1 ARCHITECTURAL GENERAL NOTES & ABBREVIATIONS D1.1 DEMOLITION PLANS AND SECTION A1.1 NEW WORK - FLOOR PLANS A1.2 REFLECTED CEILING PLAN AND ROOF PLAN A2.1 INTERIOR ELEVATIONS AND HOISTWAY DIMENSIONS A2.2 PARTIAL BUILDING SECTIONS A2.3 SECTION DETAILS A3.1 ADD ALTERNATE 1: EXTERIOR RAMP A4.1 SCHEDULES S1.0 GENERAL NOTES AND TYPICAL DETAILS S1.1 ELEVATOR NEW WORK - PARTIAL PLANS S3.1 ALTERNATE No.1: RAMP AND SLABON GRADE PLAN S4.1 SECTIONS PERMIT SUBMISSION MECHANICAL M1.1 LEGEND ABBREVIATIONS, NOTES & DETAILS M1.2 FLOOR PLAN NEW WORK 10 APRIL 2013 ELECTRICAL ARCHITECTS STRUCTURAL Penza Bailey Architects 401 Woodbourne Avenue, Baltimore, MD 21212 Tel: 410-435-6677 www.penzabailey.com Columbia Engineering, Inc. 6210 Old Dobbin Ln., Suite 150 Columbia, MD 21045 Tel: 410-992-9970 www.columbiaengineering.com E.1 E.2 E.3 E.4 ABBREVIATIONS, SYMBOLS, LIGHTING FIXTURES SCHEDULE AND GENERAL NOTES DEMOLITION AND LIGHTING PLAN - PIT, FIRST & SECOND FLOORS POWER & SPECIAL SYSTEMS PLAN - PIT, FIRST & SECOND FLOORS POWER PLAN - ELECTRICAL ROOM M.E.P. Sidhu Associates, Inc. Executive Plaza 111, Suite 1000 11350 McCormick Road, Hunt Valley, MD 21031 Tel:410.329.1115 www.sidhuai.com COVER SHEET T1.0 CODE ANALYSIS CHAPTER 7 CHAPTER 8 PROJECT SUMMARY INTERNATIONAL BUILDING CODE 2012 EDITION 1. 1. 1. JURISDICTION: ANNE ARUNDEL COUNTY 2. APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2012 INTERNATIONAL MECHANICAL CODE 2011 NATIONAL ELECTRIC CODE 2012 INTERNATIONAL PLUMBING CODE 2006 NFPA 1 2006 NFPA 101 2012 INTERNATIONAL FUEL GAS CODE CHAPTERS 16 & 17 OF THE ANNE ARUNDEL COUNTY PLUMBING CODE, 1993 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES ICC A117.1 - 2009 AND 2012 ADAAG. CHAPTER 3 1. USE AND OCCUPANCY CLASSIFICATION MAIN USE GROUP 'E' (IBC 305) CHAPTER 5 1. ALLOWABLE HEIGHT AND BUILDING AREA FOR USE 'B' WITH CONSTRUCTION TYPE 'III' B UNPROTECTED (IBC TABLE 503) GROUP E E 2. HEIGHT 55'-0" 45'-0" STORIES 2 2 AREA _ 19,888 S.F. 16,302 S.F. (PERMITTED*) (EXISTING)) *: AREA MODIFICATION AS PERMITTED ON SECTION 506.2 FRONTAGE INCREASE (IBC 2012) TO BE: 14,500 SQ.FT. x If = 14,500 SQ.FT. x 1.37 = 19,888 SQ.FT. BEING If = [409'/658' -0.25] x 30 30 = 37% AREA INCREASE CHAPTER 6 1. CONSTRUCTION TYPE TO BE 'III'' B (IBC 602.2 & TABLE 601) 2. FIRE RESISTANCE RATING FOR BUILDING ELEMENTS (HOURS) (IBC TABLES 601 & 602) STRUCTURAL FRAME BEARING EXT. WALL BEARING INT. WALL NONBEARING EXT. WALL & PART. NONBEARING EXT. WALL & PART. NONBEARING EXT. WALL & PART. NONBEARING EXT. WALL & PART. NONBEARING INT. WALL & PART. FLOOR CONSTRUCTION ROOF CONSTRUCTION 0-HR 2-HR 0-HR 1-HR 1-HR 0-HR 0-HR 0-HR 0-HR 0-HR REQUIRED REQUIRED REQUIRED REQUIRED (<5' DIST.) REQUIRED (5'<10' DIST.) REQUIRED (10'<30' DIST.) REQUIRED (>30'' DIST.) REQUIRED REQUIRED REQUIRED SHAFT ENCLOSURE SHALL BE CONSTRUCTED AS FIRE BARRIER (IBC 713.2) 2. SHAFT ENCLOSURE SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1-HOUR WHEN CONNECTING LESS THAN 4 STORIES (IBC 713.4) 3. SHAFT ENCLOSURE SHALL HAVE CONTINUITY IN ACCORDANCE WITH SECTION 707.5 (IBC 713.5). 4. FIRE BARRIER SHALL EXTEND FROM THE TOP OF THE FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING, SLAB OR DECK ABOVE AND SHALL BE SECURELY ATTACHED THERETO. SUCH FIRE BARRIERS SHALL BE CONTINUOUS THROUGH CONCEALED SPACE, SUCH AS THE SPACE ABOVE A SUSPENDED CEILING (IBC 707.5). 5. OPENINGS IN SHAFT ENCLOSURE SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716 AND SHALL BE SELF- OR AUTOMATIC CLOSING BY SMOKE DETECTION (IBC 713.7). 6. AUTOMATIC-CLOSING DOORS INSTALLED IN THE FOLLOWING LOCATIONS SHALL BE AUTOMATIC-CLOSING BY THE ACTUATION OF SMOKE DETECTORS INSTALLED IN ACCORDANCE WITH SECTION 907.3, OR BY LOSS OF POWER TO THE SMOKE DETECTOR OR HOLD-OPEN DEVICE. DOOR THAT ARE AUTOMATIC-CLOSING BY SMOKE DETECTION SHALL NOT HAVE MORE THAN A 10-SECOND DELAY BEFORE THE DOOR STARTS TO CLOSE AFTER THE SMOKE DETECTOR IS ACTUATED (IBC 716.5.9.3). 7. A SHAFT ENCLOSURE THAT DOES NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING, DECK OR SLAB OF THE BUILDING SHALL BE ENCLOSED AT THE TOP WITH CONSTRUCTION OF THE SAME FIRE-RESISTANCE RATING AS THE TOPMOST FLOOR PENETRATED BY THE SHAFT, BUT NOT LESS THAN THE FIRE-RESISTANCE RATING REQUIRED FOR THE SHAFT ENCLOSURE (IBC 713.12). 8. AN ENCLOSED ELEVATOR LOBBY IS NOT REQUIRED (IBC 713.14.1). 9. JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALLS AND ROOF SHALL BE PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL. NO FIRE-RESISTANT JOINT SYSTEM IS REQUIRED AT FLOORS WHERE THE JOINT IS PROTECTED BY A SHAFT ENCLOSURE IN ACCORDANCE WITH SECTION 713 (IBC 715.1). 10. A FIRE-RESISTANT JOINT SYSTEM SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079 (IBC 715.3). 2. INTERIOR WALL & CEILING FINISH REQUIREMENT (IBC TABLE 803.5 NON SPRINKLERED): INT. EXIT STAIRWAYS, RAMPS AND PASSAGEWAYS: CLASS 'A' CORRIDORS: CLASS 'B' ROOMS AND ENCLOSED SPACES: CLASS 'C' CURTAINS, DRAPPERIES, HANGING AND OTHER DECORATIVE MATERIALS SUSPENDED FROM WALLS OR CEILINGS SHALL MEET NFPA 701 CHAPTER 9 1. NO CHANGE TO THE FIRE PROTECTION SYSTEMS ARE PART OF THIS PROJECT. CHAPTER 10 1. NO CHANGE TO MEANS OF EGRESS ARE PART OF THIS PROJECT. CHAPTER 30 1. 2. 3. 4. 5. 6. EACH ELEVATOR CALL STATION ON ALL FLOORS, INSTRUCTING OCCUPANTS TO USE THE EXIT STAIRWAYS AND NOT TO USE THE ELEVATORS IN CASE OF FIRE (IBC 3002.3). ELEVATOR SHALL BE PROVIDED WITH PHASE I EMERGENCY RECALL OPERATION AND PHASE II EMERGENCY IN-CAR OPERATION (IBC 3003.2). ELEVATOR SHALL BE EQUIPPED TO OPERATE WITH A STANDARDIZED FIRE SERVICE ELEVATOR KEY IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE (IBC 3003.3). HOISTWAY VENTING IS NOT REQUIRED (IBC 3004.1). ELEVATOR CLOSET SHALL BE PROVIDED WITH AN INDEPENDENT VENTILATION OR AIR-CONDITIONING SYSTEM TO PROTECT AGAINST THE OVERHEATING OF THE ELECTRICAL EQUIPMENT (IBC 3006.2). MACHINE ROOM OR CLOSET IS EXEMPTED OF FIRE BARRIER (IBC 3006.4) HALL SIGNALS ELEVATOR HOISTWAY ENTRANCE 6. PROVIDE ADEQUATE SUPPORT AT ALL FASTENING POINTS OF EACH ENTRANCE. PROVIDE PLUMB VERTICAL SURFACES FOR ENTRANCES AND SILL SUPPORTS, ONE ABOVE THE OTHER, AND SQUARE WITH THE HOISTWAY. FINISH FLOOR AND GROUT BETWEEN DOORFRAMES TO SILL LINE. MRL - A HORIZONTAL THE TOP LANDING TO SUPPORT THE DOORFRAME ASSEMBLY. IF 7. HOISTWAY BARRICADES AND SCREENING SHALL BE CONSTRUCTED, MAINTAINED AND REMOVED. 8. PROVIDE AND INSTALL A FIXED VERTICAL IRON LADDER IN PIT. LADDER WIDTH AND PIT WALL POCKET REQUIREMENTS SHALL BE COORDINATED WITH ELEVATOR MANUFACTURER. REACH RANGES 4'-0" MIN. 5'-0" MAX. 3'-6" 6'-0" 15" AFF FINISH FLOOR FRONT ELEVATION 3. PROVIDE A CLEAR PLUMB HOISTWAY WITH VARIATIONS FROM THE 5. PROVIDE ADEQUATE SUPPORT FOR THE TOP RAIL BRACKETS AT LOCATIONS ABOVE THE TOP LANDING. PROVIDE SEPARATOR BEAMS WHERE REQUIRED. UNLESS APPROVED BY ELEVATOR MANUFACTURER, RAIL-BRACKET ATTACHMENT SUPPORTS MUST BE EXPOSED AND FLUSH WITH THE CLEAR HOISTWAY LINE. TACTILE SIGNAGE ON HOISTWAY ENTRANCE, BOTH JAMBS 48" AFF 2 15" CALL BUTTONS STATION HOISTWAY & PIT PREP/WORK 4. PROVIDE ADEQUATE RAIL BRACKET SUPPORTS, BRACKET SPACING AS REQUIRED EXISTING BUILDING: USE GROUP: 'E' CONSTRUCTION TYPE: IIB UNPROTECTED BASEMENT AREA: UNKNOWN 1st FLOOR AREA: 16,302 SQ.FT. 2nd FLOOR AREA: 12,512 SQ.FT. 5. TOTAL BUILDING AREA (EXCLUDING BASEMENT) 28,814 SQ.FT. FOR Anne Arundel County Public Schools CODE ANALYSIS NFPA 101 2012 EDITION GENERAL PREP/WORK DIMENSIONS SHOWN ON THE LAYOUT 4. ANNE ARUNDEL COUNTY PUBLIC SCHOOLS PHOENIX CENTER ELEVATOR COORDINATION NOTES 2. PROVIDE AND INSTALL A STEEL, I-BEAM SHAPED SAFETY BEAM AS SHOWN ON STRUCTURAL DRAWINGS, FROM SIDE WALL TO SIDE WALL AT THE TOP OF THE HOISTWAY, CAPABLE OF WITHSTANDING A MINIMUM IS REQUIRED FROM TOP OF BEAM TO TOP OF HOISTWAY. THE PROJECT IS AN ELEVATOR AND RAMP ADDITION TO THE EXISTING PHOENIX CENTER. 3.1. EXISTING BUILDING YEAR OF CONSTRUCTION 1938. 3.2. BUILDING HEIGHT AND AREA REMAIN AS EXISTING. ELEVATOR & RAMP ADDITION TO ADA CODE ANALYSIS - 2010 ADA STANDARDS 1. PROVIDE ON-SITE STORAGE AREA FOR ELEVATOR EQUIPMENT AS FOLLOWS: DRY AND ENCLOSED, PROVIDES ROLL-ABLE ACCESS TO THE ELEVATOR HOISTWAY AT THE GROUND LEVEL, LOCATED WITHIN 100 FEET OF THE HOISTWAY AND IS LARGER THAN 25 X 20 FEET . COORDINATE WITH ELEVATOR MANUFACTURER IF WARRANTIES FOR ELEVATOR EQUIPMENT ARE NULL AND VOID IF EQUIPMENT IS STORED IN A MANNER OTHER THAN A DRY ENCLOSED BUILDING STRUCTURE. 3. ELEVATOR CHAPTER 407 ELEVATORS ELEVATORS SHALL COMPLY WITH 407 AND WITH ASME A17.1. 407.2.1 - WHERE ELEVATOR CALL BUTTONS OR KEYPADS ARE PROVIDED, CALL BUTTONS SHALL BE RAISED OR FLUSH. 308 - CAR CONTROLS, CALL BUTTONS AND KEYPADS SHALL BE LOCATED WITHIN THE REACH RANGES, MEASURED TO THE CENTERLINE OF THE HIGHEST OPERABLE PART. 305 - A CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED AT CALL CONTROLS. THE CALL BUTTON THAT DESIGNATES THE UP DIRECTION SHALL BE LOCATED ABOVE THE CALL BUTTON THAT DESIGNATES THE DOWN DIRECTION. 407.2.1.5 - CALL BUTTONS SHALL HAVE VISIBLE SIGNALS TO INDICATE WHEN EACH CALL IS REGISTERED AND WHEN EACH CALL IS ANSWERED. 407.2.2.1 - A VISIBLE AND AUDIBLE SIGNAL SHALL BE PROVIDED AT EACH HOISTWAY ENTRANCE TO INDICATE WHICH CAR IS ANSWERING A CALL AND THE CAR'S DIRECTION OF TRAVEL. WHERE IN-CAR SIGNALS ARE PROVIDED, THEY SHALL BE VISIBLE FROM THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTONS. 407.2.2.2 - VISIBLE SIGNAL FIXTURES SHALL BE CENTERED AT 72 INCHES MINIMUM A.F.F.. VISIBLE SIGNAL ELEMENTS SHALL BE 2-1/2 INCHES MINIMUM MEASURED ALONG THE VERTICAL CENTERLINE OF THE ELEMENT. SIGNALS SHALL BE VISIBLE FROM THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTON. 407.2.3.1 - FLOOR DESIGNATIONS SHALL BE RAISED & BRAILLE ON BOTH JAMBS, 48" MIN. A.F.F. TO BASELINE OF LOWEST TACTILE CHARACTER AND 60" MAX. A.F.F. TO BASELINE OF HIGHEST TACTILE CHARACTER. FLOOR DESIGNATION INCLUDES TACTILE STAR AT MAIN LEVEL 407.4.3 - 1.25" MAX. DIFFERENCE BETWEEN CAR PLATFORM SILL AND EDGE OF HOISTWAY LANDING. 407.4.2 - CAR FLOOR SURFACE SHALL BE FIRM AND SLIP-RESISTANT. 407.4.6.2 - CAR CONTROL BUTTONS SHALL BE 3 4" IN THE SMALLEST DIMENSION AND ARRANGED IN ASCENDING ORDER. 407.4.6.4 - EMERGENCY CONTROL BUTTONS SHALL BE GROUPED AT BOTTOM OF PANEL AND WITH CENTERLINE AT 35" MIN. A.F.F. 407.4.7.1.1 - CAR CONTROL BUTTONS SHALL BE IDENTIFIED BY RAISED CHARACTERS, 132" MIN., UPPERCASE, SANS SERIF, HEIGHT 5 8" - 2" HEIGHT, AND BY BRAILLE IMMEDIATELY TO LEFT OF BUTTON. 407.4.7.1.3 - TACTILE SYMBOLS SHALL BE PROVIDE AS SHOWN ON TABLE 407.4.7.1.3. 407.4.8 - ELEVATOR SHALL HAVE VISIBLE AND AUDIBLE INDICATORS, PER 2010 ADA STANDARDS. CHAPTER 6 CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENTS 291 Locust Ave. Annapolis, MD 21401 CHAPTER 9.4 - ELEVATORS, ESCALATORS AND CONVEYORS 9.4.2.4 - THE ELEVATOR CORRIDOR CALL STATION PICTOGRAPH SPECIFIED IN 2.27.9 OF ASME A 17.1/CSA B44, SHALL BE PROVIDED AT EACH ELEVATOR LANDING. # DATE DESCRIPTION 9.4.3.1 - ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTERS' EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA B44 ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: 12013 9.4.2.4 PICTOGRAPH CODE REVIEW A0.0 GENERAL CONTRACTOR NOTES STANDARD ARCHITECTURAL ABBREVIATIONS 1. DURING THE BID PHASE, CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR REVIEWING AND PRICING ALL CONTRACT DOCUMENTS AS A COMPLETE SYMBOLS USED AS ABBREVIATIONS : <) ANGLE @ AT C [ O # CENTERLINE CHANNEL DIAMETER NUMBER PERPENDICULAR P PLATE CONST. CONT. CONTR. CONV. COORD. CPT. C.R. C.S. C.T. CTSK. CU. CWPA STANDARD ABBREVIATIONS : AC. ADJ. A.F.F. AGG. ALT. AL. ANOD. APC. APPX. ARCH. A.S.T.M. AUTO ASU B.C. BD. BET. BIT. B.L. BLDG. BLK. BLKG. BM. BOT. B.S. BSMT. BTU CAB. C.B. C.D. CEM. CER. C.G. C.H. C.I. C.J. CK.BD. CLOS. CLG. CM. C.M.T. C.M.U. COL. CONC. AIR CONDITIONING ADJACENT ABOVE FINISHED FLOOR AGGREGATE ALTERNATE ALUMINUM ANODIZED ACOUSTICAL PANEL CLG. APPROXIMATE ARCHITECTURAL AMERICAN SOCIETY FOR TESTING MATERIALS AUTOMATIC ACOUSTICAL SPACE UNITS BRICK COURSE BOARD BETWEEN BITUMINOUS BUILDING LINE BUILDING BLOCK BLOCKING BEAM BOTTOM BRICK SHELF BASEMENT BRITISH THERMAL UNIT CABINET CATCH BASIN CEILING DIFFUSER CEMENT CERAMIC CORNER GUARD CEILING HEIGHT CAST IRON CONTROL JOINT CHALKBOARD CLOSET CEILING CENTIMETER CERAMIC MOSAIC TILE CONCRETE MASONRY UNIT COLUMN CONCRETE CWPS CONSTRUCTION CONTINUOUS CONTRACTOR CONVECTOR COORDINATE CARPET CEILING REGISTER CEMENT SEALER CERAMIC TILE COUNTERSUNK CUBIC CEMENTIOUS WOOD-FIBER PANELS - ATTACHED CEMENTIOUS WOOD-FIBER PANELS - SUSPENDED DEMO DEP. DEPT. DET. D.H. D.F. DIA. DIAG. DIM. DIV. DN. DR. DWG. DEMOLITION DEPRESSED DEPARTMENT DETAIL DOUBLE HUNG DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DIVISION DOWN DOOR DRAWING E. EA. EC. EL. ELEC. ELEV. EMER. EMR. ENCL. ENT. EP. EQ. EQUIP. E.W.C. EXCAV. EXH. EXIST. EXP. E.J. EXT. EAST EACH END CAP ELEVATION ELECTRIC ELEVATOR EMERGENCY ELEV. MACHINE ROOM ENCLOSURE ENTRANCE EPOXY PAINT EQUAL EQUIPMENT ELECTRIC WATER COOLER EXCAVATE EXHAUST EXISTING EXPOSED EXPANSION JOINT EXTERIOR F.A.F. F.A.I. F.D. FDN. F.E. F.E.C. F.H.E.C. FACTORY APPLIED FINISH FRESH-AIR INTAKE FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE & EXTINGUISHER CABINET F.H.C. FIN. FL. FLASH. FLUOR. F.P. F.P.S.C. F.R. F.S. FT. FTG. FURR. FUT. GA. GALV. G.B. GBL. G.C. GEN. G.I. GL. G.W.B. G.W.T. GYP. H.B. HC. HDR. HDW. H.M. HOR. H.P. H.R. HR. HT. HTG. H.V.A.C. HD.WD. FIRE HOSE CABINET FINISH FLOOR FLASHING FLUORESCENT FIREPROOFING FIREPROOF -SELF-CLOSING FIRE RATING FULL SIZE FOOT FOOTING FURRING FUTURE GAUGE GALVANIZED GRAB BAR GLAZED BLOCK GENERAL CONTRACTOR GENERAL GALVANIZED IRON GLASS GYPSUM WALL BOARD GLAZED WALL TILE GYPSUM HOSE BIB FOR HANDICAPPED USE HEADER HARDWARE HOLLOW METAL HORIZONTAL HIGH POINT HANDRAIL HOUR HEIGHT HEATING HEATING, VENTILATING, AIR CONDITIONING HARDWOOD I.D. IN. INCAND. INCL. INSUL. INT. INTER. INV. INSIDE DIAMETER INCH INCANDESCENT INCLUSIVE INSULATION INTERIOR INTERMEDIATE INVERT J.C. JT. JANITOR'S CLOSET JOINT LAB. LAM. LAV. LABORATORY LAMINATED LAVATORY LBS. LH. L.L. LONG. L.P. LT.WT. M. MACH. MAINT. MAR. MAS. MAT. MAX. MECH. MED. MET. MFR. M.H. MIN. MISC. MLD. MM. M.O. MOD. MTL. N. N.I.C. NO. NOM. N.R.C. N.T.S. NFPA OA. O.C. O.D. O.H. OPNG. OPP. P. PASS. ELEV. PER. PERF. PGB PL. P.LAM. PLAS. PNL. PREFAB. PSI. PT. POUNDS LEFT HAND LIVE LOAD LONGITUDINAL LOW POINT LIGHT WEIGHT METER MACHINE MAINTENANCE MARBLE MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM METAL MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MOLDING MILLIMETER MASONRY OPENING MODULAR MATERIAL NORTH NOT IN CONTRACT NUMBER NOMINAL NOISE REDUCTION COEFFICIENT NOT TO SCALE NATIONAL FIRE PROTECTION AGENCY OVERALL ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING OPPOSITE PAINT PASSENGER ELEVATOR PERIMETER PERFORATED PAINTED GYPSUM BOARD PLATE PLASTIC LAMINATE PLASTER PANEL PREFABRICATE POUNDS PER SQUARE INCH POINT PTN. PVC. PWD. PARTITION POLYVINYL CHLORIDE PLYWOOD Q.T. QTY. QUARRY TILE QUANTITY R. RAD. R.B. R.D. REF. REG. REINF. REQD. RET. REV. R.H. RM. R.O. RISER RADIUS RUBBER BASE ROOF DRAIN REFERENCE REGISTER REINFORCING REQUIRED RETURN REVISION RIGHT HAND ROOM ROUGH OPENING S. SAN. SCHED. SECT. S.F. SIM. S.P. SPEC. SQ. S.S. ST. S.T.C. STD. STOR. STR. SUSP. SYM. SYN. SOUTH SANITARY SCHEDULE SECTION STAINED FINISH SIMILAR STARTING POINT SPECIFICATION SQUARE STAINLESS STEEL STEEL SOUND TRANSMISSION COEFFICIENT STANDARD STORAGE STRUCTURAL SUSPENDED SYMMETRICAL SYNTHETIC U.L. U.O.N. UNDERWRITER'S LABORATORY UNLESS OTHERWISE NOTED SET. 2. DRAWINGS SHALL NOT BE SCALED. 3. ALL WORK TO BE DONE IN ACCORDANCE WITH THE LATEST VERSIONS OF ALL APPLICABLE LOCAL, STATE, AND FEDERAL AUTHORITIES, CODES, RULES, AND REGULATIONS. V.P. V.C.T. VERT. V.I.F. V. V.W.C. VISION PANEL VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD VINYL VINYL WALL COVERING 4. CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS AND METHODS OF JOB SITE SAFETY. SAFEGUARD ALL WORK AREAS AGAINST PERSONAL INJURY OR DAMAGE. 5. NO MATERIALS CONTAINING ASBESTOS WILL BE USED. 6. ALL PAINTING AND COATING MATERIALS, BOTH INTERIOR AND EXTERIOR, TO BE FREE OF LEAD AND MERCURY. 7. MATERIALS SHALL HAVE LOW OR NO "VOLATILE ORGANIC EMISSIONS" (V.O.C.) COMPLIANT WITH STATE AND LOCAL REGULATIONS. 8. CONTRACTOR SHALL BE LIABLE FOR ANY DAMAGE TO BUILDING AND SHALL TAKE ALL PRECAUTIONS NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM DUST AND WATER DAMAGE. W. W/ W.C. WD. W/O W.O. W.P. W.PT. WT. W.W.F. WEST WITH WATER CLOSET WOOD WITHOUT WINDOW OPENING WATERPROOFING WORKING POINT WEIGHT WELDED WIRE FABRIC 9. PROTECT ALL EXISTING FINISHES TO REMAIN, FURNITURE, FIXTURES, EQUIPMENT, AND PERSONAL ITEMS. 10. ALL WORK SHALL BE DONE IN WORKMANLIKE MANNER AND IN CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND GUARANTEE REQUIREMENTS. 11. DEMOLITION, CUTTING AND PATCHING OF ANYTHING REQUIRED TO CONSTRUCT THE PROJECT IS HEREIN MADE A PART OF THESE DOCUMENTS. 12. CONTRACTOR SHALL MAKE THEMSELVES FAMILIAR WITH ALL SITE CONDITIONS, UTILITIES, ELEVATIONS AND DIMENSIONS PRIOR TO START OF WORK. THE CONTRACTOR IS TO CONTACT THE OWNER/ ARCHITECT FOR ANY DISCREPANCIES. THE CONTRACTOR IS RESPONSIBLE FOR SURVEY, LAYOUT, AND COORDINATION OF ALL WORK. ANNE ARUNDEL 13. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND CONFIRMING ALL QUANTITIES IN ACCORDANCE W/ THE CONTRACT DOCUMENTS. LISTED QUANTITY COUNTY PUBLIC SCHOOLS ASSUMPTIONS ARE FOR BIDDING PURPOSES ONLY. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND CONFIRMING ALL QUANTITIES. 14. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DIMENSIONS SHOWN ARE FOR ESTIMATING PURPOSES ONLY. NO ADDITIONAL COST WILL BE PAID FOR VARYING DIMENSIONAL CONDITIONS. 15. ALL DIMENSIONS SHOWN ON DRAWINGS ARE NOTED FROM FINISH MATERIAL TO FINISH MATERIAL, UNLESS NOTED OTHERWISE. 16. ANY UNFORESEEN OR UNCLEAR CONDITIONS, ANY CONFLICT IN THE DRAWINGS OR BETWEEN DRAWINGS AND SPECIFICATIONS ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL WRITTEN CLARIFICATION FROM THE ARCHITECT IS RECEIVED. 17. ANY DEVIATION FROM, OR IN FIELD ALTERATION TO THESE DRAWINGS AND SPECIFICATIONS IS STRICTLY PROHIBITED WITHOUT PRIOR APPROVAL OF ARCHITECT OR OWNER. ANY SUCH ALTERATIONS SHALL BE CORRECTED AT ONCE, WITH NO EXPENSE TO THE OWNER. 18. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL UTILITY SERVICE CONNECTIONS TO ALL EQUIPMENT TO INSURE THAT THE EQUIPMENT IS IN FULLY FUNCTIONAL OPERATIONS E.I. WIRING DEVICES, POWER SUPPLIES, ACCESSORIES, CONTROLS, CONDUIT, SUPPORTS, FASTENERS, PIPING, ETC. 19. REFER TO STRUCTURAL DRAWINGS FOR ALL MEMBER SIZES, INCLUDING BEAMS AND FOOTING SIZE AND DEPTH, AND FOUNDATION WALL MATERIAL AND SIZE. 20. NO ITEMS SHALL BE SUPPORTED OR HUNG FROM EACH OTHER. G.C. SHALL CONFIRM WITH STRUCTURAL ENGINEER IF SUSPENDED ITEMS CAN BE FASTENED T.&B. TB. T.C. T.D. TEL. TEMP. TER. T.&G. THK. THRU T.O. T.O.S. TR. TV. T.W. TYP. TOP AND BOTTOM TACKBOARD TERRA COTTA TRENCH DRAIN TELEPHONE TEMPERED TERRAZZO TONGUE AND GROOVE THICKNESS THROUGH TRIMMED OPENING TOP OF SLAB TREAD TELEVISION TOP OF WALL TYPICAL SECURELY TO WALLS AND/OR STRUCTURAL MEMBERS. ELEVATOR & RAMP ADDITION TO 21. CONTRACTOR SHALL COORDINATE WORK OF ALL TRADES UNDER THIS CONTRACT. 22. PROVIDE ELECTROLYTIC PROTECTION WITH BITUMINOUS COATING BETWEEN ALL DISSIMILAR METALS, BETWEEN METAL AND CONCRETE/CMU WALL AND AT DOOR/LOUVER FRAMING. PHOENIX CENTER 23. ALL NAILERS, BLOCKING, SHIMS OR FURRING AND OTHER ROUGH CARPENTRY FOR USE AT LOCATIONS SHOWN ON DRAWINGS SHALL BE PRESSURE AND FIRE-RETARDANT TREATED. GROUND-CONTACT APPLICATION TO PRESERVATIVE TREATMENT SHALL FOLLOW THE AMERICAN WOOD PROTECTION ASSOCIATION (AWPA). FOR Anne Arundel County Public Schools 24. ALL WOOD WITHIN FIRE-RATED EXTERIOR WALL AND ROOF SYSTEM SHALL BE FIRE-TREATED AND PRESSURE-TREATED. 25. ALL EXPOSED TO VIEW CONCRETE SURFACES SHALL HAVE CLASS "A" FINISH. 26. CUT NEATLY AROUND ALL DUCTS, BEAMS, PIPING, ETC. IN EXPOSED AREAS AND SEAL TIGHT. 27. PROVIDE SEALANT AT ALL FIXTURES AND CHANGE IN MATERIAL, TYPICAL, AND AS REQUIRED BY APPLICABLE STATE HEALTH DEPARTMENT. 28. FIRESEAL AND FIRESAFE ALL VOIDS IN EXPOSED AND UNEXPOSED WALL, CEILING AND ROOF ASSEMBLIES. 291 Locust Ave. Annapolis, MD 21401 29. COMPLETE ALL WORK, READY IN ALL RESPECTS FOR ITS INTENDED USE, ACCEPTABLE TO OWNER. # DATE DESCRIPTION ISSUED FOR: MATERIALS AND SYMBOLS KEY NO SCALE REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET INDICATES SECTION NUMBER BUILDING SECTION GYPSUM WALLBOARD INDICATES SHEET WHERE SECTION IS DRAWN DRAWN: PBL WALL / DETAIL SECTION CHECKED: DGM ELEVATION INDICATOR DATE: 4/10/13 PROJECT #: 12013 METAL SECTION CMU BATT INSULATION FRAMING LUMBER RIGID INSULATION DETAIL INDICATOR EARTH WINDOW SYMBOL CONCRETE FINISH WOOD __ B BRICK PLYWOOD PARTITION INDICATOR ARCHITECTURAL GENERAL NOTES & ABBREVIATIONS DOOR SYMBOL PARTICLE BOARD 1 SPECIFIC SHEET NOTES A0.1 DEMOLITION PLAN NOTES EXISTING CORRIDOR 15 1 CAREFULLY REMOVE EXISTING STONE WALK, STEPS AND FOOTINGS TO ACCOMMODATE NEW CONCRETE WALK AND STAIR. 2 REMOVE EXISTING TREE STUMPS AND ASSOCIATED ROOTS. 3 CAREFULLY REMOVE PORTION OF EXISTING RETAINING RAIL ROAD TIES, FASTENERS AND RELATED CONSTRUCTION. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. 4 EXCAVATE SITE AS NEEDED AND REMOVE EXISTING VEGETATION WITHIN DASHED AREA. 5 SEE STRUCTURAL DRAWINGS FOR POTENTIAL DEMOLITION WORK AT EXISTING PIERS. 6 CAREFULLY REMOVE PORTION OF WOOD FRAMING, FASTENERS AND RELATED CONSTRUCTION. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SEE STRUCTURAL DWGS. SEE GEN. DEMO NOTE 2 BELOW. EXISTING CORRIDOR 7 CAREFULLY REMOVE PORTION OF WOOD FLOORING, FASTENERS AND RELATED CONSTRUCTION. FRAMING REMOVAL SHALL FOLLOW STRUCTURAL DRAWINGS AND NOTES. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SEE STRUCTURAL DWGS. SEE GEN. DEMO NOTE 2 BELOW. 8 CAREFULLY REMOVE PORTION OF ROOF/CEILING, FASTENERS AND RELATED CONSTRUCTION. ROOF REMOVAL SHALL KEEP STRUCTURAL INTEGRITY OF STEEL BEAMS BELOW. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SALVAGE ACT AND REMOVE PORTION OF GRID. PREP REMAINING GRID AND SALVAGED ACT FOR NEW CONSTRUCTION. SEE STRUCTURAL DEMO DWGS. SEE GEN. DEMO NOTE 2 BELOW. 12 EXISTING STORAGE 9 6 CORRIDOR 9 REMOVE EXISTING DOOR, FRAMES, FASTENERS AND RELATED CONSTRUCTION. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SEE GEN. DEMO NOTE 2 BELOW. 11 REMOVE SEGMENT OF PARTITION, FASTENERS AND RELATED CONSTRUCTION. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SEE GEN. DEMO NOTE 2 BELOW. 12 SALVAGE BOARD AND INSTALL OR CLEAN AT OWNER'S INSTRUCTIONS. 13 .NOT USED D 16 10 6 REMOVE PORTION OF MASONRY WALL AND RELATED CONSTRUCTION. PREP REMAINING SURFACES FOR NEW CONSTRUCTION AND/OR PATCH. SEE GENERAL DEMOLITION NOTE 2 BELOW. 10 D1.1 7 ANNE ARUNDEL COUNTY PUBLIC SCHOOLS D D1.1 16 UPPER AUDITORIUM 14 11 10 CAREFULLY REMOVE WALL PADS, FASTENERS AND RELATED CONSTRUCTION. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. 15 CAREFULLY REMOVE PORTION OF CEILING, FASTENERS AND RELATED CONSTRUCTION. SALVAGE LIGHTING FIXTURES. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SEE GEN. DEMO NOTE 2 BELOW. 16 CAREFULLY REMOVE PORTION OF GRID SUSPENSION SYSTEM, FASTENERS AND RELATED CONSTRUCTION. SALVAGE LIGHTING FIXTURES AND ACOUSTICAL PANELS. PREP REMAINING SURFACES FOR NEW CONSTRUCTION. SEE GEN. DEMO NOTE 2 BELOW. 11 EXISTING ENTRY CORRIDOR EXISTING AUDITORIUM 14 14 CORRIDOR BALCONY ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools EXISTING OFFICE DN 291 Locust Ave. Annapolis, MD 21401 UP # DATE DESCRIPTION 2 B A 1ST FLOOR DEMOLITION PLAN 1/4" = 1'-0" 2ND FLOOR DEMOLITION PLAN 1/4" = 1'-0" 1 GENERAL DEMO NOTES 8 4 3 1. DASHED LINES INDICATE CONSTRUCTION TO BE REMOVED. 2. REFER TO "ASBESTOS VERIFICATION FORM"ON SHEET T1.0. 3. PROTECT EXISTING FINISHES SCHEDULED "TO REMAIN" 4. SEE MEP DRAWINGS FOR MEP RELATED DEMOLITION. 5. PATCH AND REPAIR DEMOLITION AREA TO MATCH EXISTING AT NO EXPENSE TO THE OWNER BEFORE/ AFTER INSTALLING NEW MATERIALS. UP 6. CAREFULLY COVER AND PROTECT ALL FLOORS TO REMAIN DURING CONSTRUCTION. CLEAN ALL FLOORS IN AND AROUND CONSTRUCTION AREAS AFTER COMPLETION OF CONSTRUCTION WORK. 7. 8 10'-8" ISSUED FOR: BALCONY 7 6 ALL ITEMS SLATED FOR DEMOLITION SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. 1 1 3 1 8. INVESTIGATION AND SURVEY OF THE FACILITIES' ANY SERVICES, SYSTEMS, EXIST. CONCRETE SIDEWALK CORRIDOR IF DURING THE EXECUTION OF THE SCOPE OF WORK OR DURING THE EXPLORATION, STRUCTURE, SUBSTRUCTURE, FINISHES, FURNISHINGS, FIXTURES AND EQUIPMENT ARE DISTURBED/DAMAGED, THE CONTRACTOR MUST MAKE THE REPAIRS OF RESTORATION REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET WITHIN 24 HOURS OR SOONER, IN ORDER TO RETURN THE DISTURBED/DAMAGED AUDITORIUM ITEM(S) TO ITS INTENDED USE. ACCEPTANCE OF THE REPAIR/RESTORATION IS SUBJECT 13'-6" TO THE OWNER'S SATISFACTION/APPROVAL AND SHALL BE EXECUTED AT NO 9 9. CHECKED: DGM DATE: 4/10/13 CORRIDOR 2' 0 1' 2' "PROFESSIONAL CLEANING SERVICES CONTRACTOR AND THE OWNER" ONLY ACCEPTABLE STANDARD IS "WHITE GLOVE CLEAN." CRAWL SPACE C ADD ALTERNATE #1: SITE DEMOLITION 1/4" = 1'-0" PROJECT #: 10. THE RESTORATION OF THE SCHOOL'S FACILITIES FOR SCHOOL ACTIVITIES IN OCCUPIED AREAS INCLUDES THE REINSTALLATION OF THE ACT SYSTEM & COMPONENTS, SCALE 1/4" = 1'-0" 4' 8' DEMOLITION PLANS AND SECTION RESTORATION OF ALL MEP/FA/FS/TELECOM/DATA SERVICES AND DUST DIRT & DEBRIS REMOVAL ALONG WITH THE PROFESSIONAL CLEANING AT NO COST TO THE OWNER. D SECTION THROUGH GALLERY 1/8" = 1'-0" 12013 THE CONTRACTOR IS RESPONSIBLE FOR CLEANUP OF THE ROOMS & AREAS USED FOR NEXT DAY'S NORMAL SCHOOL ACTIVITIES THAT OCCUR INSIDE & OUTSIDE THE 5 PBL ADDITIONAL COST TO THE OWNER. STORAGE 6 DRAWN: NOTE: CONTRACTOR EXECUTION OF THE CONTRACT CANNOT DISRUPT THE NORMAL ADD ALTERNATE SITE DEMOLITION INCLUDES ITEMS: 1, 2, 3, 4, AND 13. DAY-TO-DAY OPERATION OF THE SCHOOL. 11. ALL ITEMS SLATED FOR DEMOLITION SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. D1.1 CRAWL SPACE D D B D B A2.2 A2.2 A2.1 A2.2 A2.1 EXISTING CORRIDOR EXISTING CORRIDOR ANNE ARUNDEL NEW 1-HR FIRE BARRIER (HOISTWAY), PER UL U905 PIT LADDER OUTLINE OF BALCONY ABOVE 8" CMU, 1-HR FIRE BARRIER (HOISTWAY) PER UL U905 SEE STRUCT. DWGS FOR PIERS AND NEW FLOOR FRAMING 6'-5" +/- NEW PIT LADDER 8'-0" 1" COUNTY PUBLIC SCHOOLS NEW MTL STUD WITH DRYWALL TO 6" ABOVE LAY-IN CLG. NEW 1-HR FIRE BARRIER ELEVATOR SHAFT (HOISTWAY), PER UL U905 1" NEW STORAGE D-3 F 7'-4" A2.3 OUTLINE OF EXIST. BULKHEAD ABOVE CLR. E C A2.3 A2.2 EXISTING MASONRY FOUNDATION WALL EQ. C A2.2 EXISTING STORAGE ROOM NEW 24"x72" WALL PROTECTION PAD A 1'-8" MIN. A CRAWL SPACE 2"X8" @ 16" O.C. EXIST. JOISTS CRAWL SPACE NEW 5 8" GYP. BD. ON 7 8" MTL CHANNEL, ON CMU WALL NEW 24"x24"x72" 'L' SHAPE WALL PROTECTION PAD, SEE NOTE BELOW. A A A2.2 A2.2 291 Locust Ave. Annapolis, MD 21401 EXISTING BALCONY NEW 24"x72" WALL PAD 8'-6" +/- FOR Anne Arundel County Public Schools EXISTING CORRIDOR NEW 24"x24"x72" 'L' - SHAPE WALL PAD 1'-1" +/- PHOENIX CENTER NEW 5 8" GYP. BD. ON 3-1/2" MTL STUDS TO CONCEAL PIPING TO ROOF. UPPER AUDITORIUM D-1 EXISTING AUDITORIUM ELEVATOR & RAMP ADDITION TO A2.1 NEW ELEVATOR CLOSET 1-HR RATING A D-2 CENTERLINE OF ELEVATOR OPNG. TO MATCH CENTERLINE OF EXISTG M.O. EXIST. CORRIDOR A A2.1 24"x24" SUMP PUMP PIT AND MTL. GRATE EXIST. M.O. 8'-6" 6"X10" WOOD GIRDER CL EQ. C A2.2 9'-10" ELEV. PIT 3'-6" +/NEW OPNG. 6'-8" # DATE DESCRIPTION 8'-8" +/- 1'-1" +/- EXISTING OFFICE EXISTING MASONRY PIER, TYP. ISSUED FOR: C CRAWL SPACE PLAN 1/4" = 1'-0" B 1ST FLOOR PLAN 1/4" = 1'-0" A 2ND FLOOR PLAN 1/4" = 1'-0" NOTE: WALL AND L-SHAPE WALL PAD BASIS OF DESIGN: DRAPER ECOVISION, COLOR GREY, MOUNTED ON Z-CLIPS AT TOP AND BOTTOM. REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: 12013 NEW WORK FLOOR PLANS 2' 0 1' 2' SCALE 1/4" = 1'-0" 4' 8' A1.1 D D B D B A2.2 A2.2 A2.1 A2.2 A2.1 ANNE ARUNDEL COUNTY PUBLIC SCHOOLS NEW 4" EXHUST VENT W/ CAP, SEE MECH. DWGS. N RELOCATE NEW CEILING AND GRID. EXISTING PARAPET WALL EXISTING ROOF NEW CEILING MOUNTED LIGHT FIXTURE, SEE ELECT. DWG. RELOCATE N = 12 MIN. SLOPE C A2.2 A2.2 N A2.2 RELOCATE C 4-PLY BUILT-UP ROOFING CU-1. SEE MECH DWGS. FOR EQUIPMENT AND CURB C NEW GRID, INSTALL SALVAGED PANELS 4 RELOCATE PIPE PENETRATION THROUGH ROOF. SEE MECH DETAILS EXISTING EXHAUST FAN NEW CEILING MOUNTED LIGHT FIXTURE, SEE ELECT. DWG. ELEVATOR & RAMP ADDITION TO PHOENIX CENTER N 1 HR. RATED CEILING. 2 LAYER TYPE 'X' GYP. BOARD ON METAL STUDS. EXISTING GRID TO REMAIN 1 RELOCATE FOR Anne Arundel County Public Schools A A A2.2 A2.2 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION EXISTING SCREEN TO REMAIN ISSUED FOR: C ROOF PLAN 1/4" = 1'-0" B 2ND FLOOR RCP A 1/4" = 1'-0" 1ST FLOOR RCP 1/4" = 1'-0" REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET REFLECTED CEILING PLAN LEGEND EXISTING 2' X 2' SUSPENDED ACOUSTICAL TILE 2' X 2' SUSPENDED ACOUSTICAL TILE PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: 2' X 4' FLUORESCENT FIXTURE, REFER TO ELECTRICAL DRAWINGS 1' X 4' FLUORESCENT FIXTURE, SURFACE MOUNTED. REFER TO ELECTRICAL DRAWINGS 12013 REFLECTED CEILING PLAN AND ROOF PLAN SUSPENDED W.P. GYPSUM BOARD CEILING, PAINTED EXISTING 2' X 4' FLUORESCENT FIXTURE, DRAWN: 2' 0 1' 2' SCALE 1/4" = 1'-0" 4' 8' A1.2 HOIST BEAM 12'-7" TO 14'-7" 8" CMU, 1-HR FIRE BARRIER PER UL 905 ANNE ARUNDEL 7'-0" OUTLINE OF HOIST BEHIND COUNTY PUBLIC SCHOOLS GYP.BD. MTL. FURRING, ON CMU. 2ND FLOOR EXIST. SUSPENDED CLG. 13'-7" +/- (EXISTING - V.I.F.) HOISTWAY 8'-0" 3'-6" 6'-6" 7'-0" CAR D-3 1ST FLOOR PHOENIX CENTER OUTLINE OF HOISTWAY BEYOND PIT LADDER 5'-1" BALCONY ELEVATOR & RAMP ADDITION TO 5'-0" 8'-6" 9'-10" 7'-9" 6'-8" EXISTING ACT ON NEW GRID CEILING. FOR Anne Arundel County Public Schools 24"x72" WALL PAD AND 24"x24"x72" 'L'-SHAPE WALL PAD, TYP. PIT SUMP PIT AUDITORIUM 291 Locust Ave. Annapolis, MD 21401 C 3000# ELEV. HOISTWAY DIMENSIONS & PLAN 1 A 4" = 1'-0" ELEVATION FROM AUDITORIUM # DATE DESCRIPTION 1/4" = 1'-0" LIGHT FIXTURE, TYP. SEE ELECT. DWGS OUTLINE OF HOISTWAY BEYOND EXISTING MASONRY OPENING 2ND FLOOR CORRIDOR GYP. BD. ELEV. DOOR AND FRAME WOOD BASE 2ND FLOOR ELEV. 69'-1" (EXISING) 1ST FLOOR CORRIDOR GLAZED CMU TO MATCH ADJACENT MASONRY ISSUED FOR: ELEV. DOOR AND FRAME REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET ELEV. CONTROL, TYP. 1ST FLOOR ELEV. 55'-6" (EXISITNG) B ELEVATION FROM CORRIDOR DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: 12013 1/4" = 1'-0" INT. ELEVATIONS AND HOISTWAY DIMENSIONS 2' 0 1' 2' SCALE 1/4" = 1'-0" 4' 8' A2.1 REINSTALL ACT ON NEW GRID 8" CMU HOIST, FURRED WITH GYP. BD. BALCONY CURTAIN SCREEN HOISTWAY BEYOND 2ND FLOOR CORRIDOR EXIST. 2"x8" @ 18", TYP. ANNE ARUNDEL COUNTY PUBLIC SCHOOLS EXIST. 24"-WF-98# TO REMAIN UNTOUCHED B A2.2 AUDITORIUM EXIST. WD. BALCONY GUARD ENTRY CORRIDOR GYP. BD. PTN, PTD. TO MATCH EXISTING WALL PAD D-2 EXIST. 7"-C-98# D-1 1ST FLOOR CORRIDOR WD. BASE, PTD. TO MATCH EXISTING EXIST. 2"x8" @ 18", TYP. EXIST. 2"-C 8"-13.7# ENTRY CORRIDOR GYP. BD. PTN, ELEVATOR & RAMP ADDITION TO CRAWL SPACE EXISTING BALCONY STRUCTURE DETAIL B 1/2" = 1'-0" INSULATION AND FIBER BOARD 4-PLY B.U.R. PHOENIX CENTER OUTLINE OF PIT BEYOND A CONCRETE OVER COMPOSITE DECK, PER UL DESIGN No D916 FOR Anne Arundel County Public Schools SECTION THROUGH AUDITORIUM ENTRY CORRIDOR 1/4" = 1'-0" B A A2.3 A2.3 EXISTING 10WF STL BEAM TO REMAIN 291 Locust Ave. Annapolis, MD 21401 EXISTING 10WF STL BEAM TO REMAIN # HOIST BEAM 10'-8" 12'-7" to 14'-7" CURTAIN SCREEN F A2.3 7'-0" CORRIDOR REINSTALL ACT 15'-3 1/2" 12'-7" to 14'-7" BALCONY DESCRIPTION HOIST BEAM 7'-0" 2ND FLOOR DATE BALCONY 2ND FLOOR CORRIDOR C A2.3 BALCONY HOISTWAY AUDITORIUM E A2.3 1ST FLOOR CORRIDOR NEW MASONRY OP'G 1ST FLOOR EXIST. STORAGE 7'-9" STORAGE EXIST. OFFICE 13'-6" +/- (EXISTING V.I.F.) HOISTWAY ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET D CORRIDOR A2.3 DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: PIT LADDER CRAWL SPACE CRAWL SPACE PIT SECTION THROUGH ELEV. HOIST 1/4" = 1'-0" PIT PARTIAL BUILDING SECTIONS SUMP PUMP W/ MTL GRATE WATERPROOFING TYP. SUMP PUMP W/ MTL. GRATE WATERPROOFING D LADDER C SECTION THROUGH ELEV. HOIST 2' 0 1' 2' 1/8" = 1'-0" SCALE 1/4" = 1'-0" 4' 8' A2.2 12013 EXISTING V.I.F. EXISTING V.I.F. 4-PLY B.U.R. 8" CMU WALL. SEE PLAN 1" EXISTING CMU. VERIFY IN FIELD EXISTING CMU., V.I.F. 3" 3" TAPERED INSULATION AND FIBER BD. MODIFIED BITUMEN CAP SHEET 3" 1" EXPAN. JT. MTL COUNTER FLASHING EXIST. GLAZED MASONRY HOIST DOOR MOTOR, PER ELEV. MNF'R P.T. WD. CANT FULL PERIMETER SEALANT 1 2" P.T. WD. BLKG., AS REQD. ELEV. HOISTWAY 'J'-BEAD GYP. BD. WD. BLKG. AS REQD., TYP. 5 BOND BEAM. SEE STRUCT DWGS 8" FULL PERIMETER SEALANT MTL. HEAD FRAME PER ELEV. MNF'R 5 CONCRETE ON COMPOSITE DECK. SEE STRUCT. DETAILS 3 3 1 4" x 4" - 4 ROUND WD TRIM, STAINED TO MATCH EXISTING 8" CMU WALL. SEE STRUCT DWGS MTL. PLATE PTD. GYP. BD. ON 7 " FURRING 8 CHANNEL 5 8" BOND BEAM ELEV. HOISTWAY GYP. BD., TYP. FULL PERIMETER SEALANT EXIST. JAMB BEYOND EXISTING WALL ANNE ARUNDEL COUNTY PUBLIC SCHOOLS 1" AIR SPACE MTL. JAMB FRAME PER ELEV. MNF'R 8" CMU WALL. SEE STRUCT. DWGS HEAD DETAIL AT 2ND FLR. LANDING G CAULKING FULL PERIMETER SEALANT 8" P.T. WD. BLKG. AS REQD. HOISTWAY DOORS PER ELEV. MNF'R CONT. FLASHING CLEAT F 1 1/2" = 1'-0" JAMB DETAIL AT 2ND. FLR. A 1 1/2" = 1'-0" SECTION DETAIL AT ROOF 1 1/2" = 1'-0" 4 PLY B.U.R. MODIFIED BITUMEN CAP SHEET 3" 3" 3" EXISTING V.I.F. EXISTING V.I.F. CONCRETE ON COMPOSITE DECK. SEE STRUCT. DETAILS EXISTING CMU. VERIFY IN FIELD MTL PLATE PER STRUCT. DWGS, TYP. 1" 1" EXPAN. JT. EXISTING CMU., V.I.F. ELEVATOR & RAMP ADDITION TO 1'-6" 8" CMU WALL. SEE PLAN 2'-0" HT. MODIFIED BITUMEN CAP SHEET MTL COUNTER FLASHING AND CLIP EXIST. GLAZED MASONRY HOIST DOOR MOTOR, PER ELEV. MNF'R 8" CMU WALL. SEE STRUCT. DWGS ELEV. HOISTWAY MODIFIED BITUMEN CAP SHEET GLAZED CMU TO MATCH ADJACENT 8" CMU WALL. SEE STRUCT DWGS INTERPLY 1" EXISTING ROOF COVERING V.I.F. BOND BEAM. SEE STRUCT DWGS 3" STL. ANGLE. SEE STRUCT. HOISTWAY DOORS PER ELEV. MNF'R JAMB FRAME BEYOND FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION 3" P.T. WD. CANT STRUCT. PLATE MTL. HEAD FRAME PER ELEV. MNF'R PHOENIX CENTER ELEV. HOISTWAY MTL. JAMB FRAME PER ELEV. MNF'R (FULL DEPTH OF JAMB) P.T. WD. BLKG. AS REQD. HEAD DETAIL AT 1ST FLR. LANDING E 1 1/2" = 1'-0" JAMB DETAIL AT 1ST. FLR. B 1 1/2" = 1'-0" 1 1/2" = 1'-0" FULL PERIMETER SEALANT GYP.BD. COVER AT EXIST. JAMB JAMB FRAME BEYOND HOISTWAY DOORS PER ELEV. MNF'R WALL FRAME BEYOND EXIST. TERRAZZO HOISTWAY DOORS PER ELEV. MNF'R BRICK JAMB EXIST. TERRAZZO TERRAZZO TO MATCH EXISTING UNDERSIDE OF FLOOR DECK SECTION DETAIL AT ROOF TERRAZZO TO MATCH EXISTING ALUM. SILL ASSEMBLY ALUM. SILL ASSEMBLY E.J. METAL ANGLE BY ELEVATOR MNF'R 5" 4" +/- E.J. ISSUED FOR: 4" +/- H GROUT INFILL AND POUR STOP ANGLE J CMU WALL @ ELEVATOR HOIST WAY 1 1/2" = 1'-0" 2-HR FIRE RATED ASSEMBLY PER U.L. 905 I PARTITION TYPE 'A' 1 1/2" = 1'-0" 3 5/8" GALV. MTL. STUD 16" O.C. 1" ELEV. HOISTWAY ELEV. HOISTWAY 6"X4" ANGLE W/ HEADED STUDS EMBEDDED INTO CMU CRAWL SPACE 6"X4" ANGLE W/ HEADED STUDS EMBEDDED INTO CMU 8" CMU WALL. SEE STRUCT DWGS 8" CMU WALL. SEE STRUCT DWGS 1" AIR SPACE 1" AIR SPACE EXISTING WALL EXISTING WALL D AS-BUILTS BID REVISIONS PERMIT 95% CD SET GROUT INFILL AND POUR STOP ANGLE 8" CMU 2-HR FIRE RATED ASSEMBLY PER U.L. U419. 2 LAYERS TYPE 'X' GYP. BD, EACH SIDE REVIEW SECTION DETAIL AT 1ST FLR. LANDING 1 1/2" = 1'-0" C SECTION DETAIL AT 2ND FLR. LANDING 1 1/2" = 1'-0" DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: SECTION DETAILS A2.3 12013 D A3.1 3'-0" RAILING w/ 3 / 4" SQ. MTL. PICKETS. MAX SPACING OF PICKETS 4" O.C., PAINTED. NEW CONC. SIDEWALK/RAMP. TYP. HANDRAIL NEW CONCRETE CURB 6" 3 12" EXIST. SIDEWALK CORE DRILL HOLE, W/ NON-SHRINK GROUT E 54.25' ANNE ARUNDEL EXISTING. COUNTY PUBLIC SCHOOLS 3 12" TYP. HANDRAIL DETAIL ELEVATION B 3/4" = 1'-0" 1/4" = 1'-0" FACE OF EXISTING BUILDING, BEYOND. 4 1/2" TYP. MTL. HANDRAIL PAINTED 3'-6" CLR. TYP. 4 1/2" ELEVATOR & RAMP ADDITION TO CLASSROOM 100 PHOENIX CENTER 4 1/2" 3'-6" CLR. TYP. D A3.1 SOUTH-EAST LOBBY EXIST. 28" HT. WD. RETAINING WALL MTL. HANDRAIL, TYP. 3'-0" 55.5' (EXISTING V.I.F)) LANDING. SLOPE 1:48 MAX. 3'-0" SLOPE 1:20 MAX. 2'-4 1/2" 4 EQ. R. 10'-6" 4 1/2" 3'-6" 3'-6" 54.375' 4 1/2" E A3.1 5'-0" 1'-0" 16'-11" +/- EQ. 55.21' 5'-10" 41'-9 1/2" +/- V.I.F. 11'-6" EQ. LANDING LEVELED GRADING, SODDED. ALL DISTURBED AREA SHALL BE TOPSOILED TO A DEPTH OF 4" AFTER COMPACTION SLOPE TO DRAIN. NEW MTL. HANDRAIL, PTD. TYP. NEW MTL. HANDRAIL, PTD. TYP. 52.50' (EXISTING V.I.F.) NEW TYP. CONC. SIDEWALK. EXIST. CONC. SIDEWALK TYP. CONC. SIDEWALK. B 5'-3" +/- A3.1 1" NOSING SEE STRUCT DWGS. FOR REINFORCING 12" TREAD ISSUED FOR: 4'-0" NEW CONC. STAIRS. 52.5' (EXISTING V.I.F)) 53.25' LANDING 2'-9" 1'-4" 3 TREADS 1'-0" EXIST. SIDEWALK 53.375' 13'-0" 8" 12" 5'-0" CLEAR 54.25' HANDRAIL PTD. TYP. NEW CONC.SIDEWALK: 5" T. CONC.OVER 6" GRAVEL ON COMPACT FILL., TYP. NEW HANDRAIL SEE DETAIL E/A3.1 54.25' DOWN 4 = RISERS CONSTRUCTION JT. DESCRIPTION RAMP DOWN 1:12 MAX. SLOPE DOWN 4= RISERS 1" EXPAN. JT. 1'-0" TYP. CONC. SIDEWALK: - 5" T. REINF. CONC. SLAB - 6 MIL VB - 4" GRAVEL - COMPACT FILL. 1/2" = 1'-0" DATE RAMP DOWN 1:12 MAX SLOPE 4 1/2" ' 21'-4" +/- ( EXISTING V.I.F.) D ELEVATION AT RAMP 55.5' (MATCH EXISTING FF.) # CONC. RAMP, TYP. 4 1/2" 55.5' (EXISTING V.I.F)) 1 / 2 " EXPAN. JT, TYP. 291 Locust Ave. Annapolis, MD 21401 8'-6" EXITING OFFICE C A3.1 4'-3" TYP. CONC. RAMP. SEE STRUCT. DWGS. HANDRAIL. SEE DETAIL E/A3.1. 4'-3" 4 1/2" 4'-0" EXIST. SIDEWALK FOR Anne Arundel County Public Schools A REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: ADD ALTERNATE 1: EXTERIOR RAMP NEW RAMP FLOOR PLAN 1/4" = 1'-0" NEW ELEVATOR C SECTION THROUGH STEPS 2' 0 1' 12013 2' 1/2" = 1'-0" SCALE 1/4" = 1'-0" 4' 8' NEW RAMP A3.1 DOOR SCHEDULE DOOR X FRAME/CASING DOOR TYPES REMARKS HEAD JAMB THRESHOLD HARDWARE - HM1 HM FP H1 J1 - 1 D-2 2 SCW FP 3'-0" X 7'-0" - HM2 HM FP H1 J1 - 2 D-3 2 SCW FP 3'-0" X 7'-0" - HM2 HM FP H1 J1 - 3 STC FINISH 3'-6" X 7'-0" (LISTED IN MINUTES) MATERIAL FP FIRE RESISTANCE TYPE SCW GLASS TYPE NOMINAL DOOR OPENING SIZE: 1 OTHERWISE) FINISH THICK, UNLESS NOTED MATERIAL D-1 OPENING NO. TYPE (ALL DOORS ARE 1-3/4" DETAILS 60 DOOR FRAME TYPES ANNE ARUNDEL COUNTY PUBLIC SCHOOLS DOOR SCHEDULE LEGEND DOOR AND FRAME FINISHES FRAME MATERIAL HM - HOLLOW METAL FINISH SCHEDULE FLOOR BASE CEILING -- EXISTING STORAGE ROOM W1 F-1 B1 C2 -- ELEVATOR CONTROL CLOSET W1 F1 B1 C2 -- BALCONY STORAGE W1 F2 B1 REMARKS 1/2" PAINTED SILICONE SEALANT, BOTH SIDES (TYP) 1/2" H.M. FRAME C1 1 15/16" -- BALCONY W1 F2 B1 PAINTED SILICONE SEALANT, BOTH SIDES (TYP) 4 7/8" 1 15/16" C1 5 7/8" DOOR H1 HEAD ELEVATOR & RAMP ADDITION TO H.M. FRAME DOOR 2" PROVIDE STUD ANCHOR, 3 PER JAMB, TYP. J1 PHOENIX CENTER 5 7/8" WALLS 1 15/16" C 1 15/16" B 1/2" ROOM NAME F 1/2" ROOM# W DOOR TYPES 4 7/8" FP - FIELD PAINT FF - FACTORY FINISH 2" DOOR MATERIAL SCW - SOLID CORE WOOD FOR Anne Arundel County Public Schools JAMB 291 Locust Ave. Annapolis, MD 21401 W=WALLS F=FLOOR B=BASE C=CEILING # W1 = PAINT F1 = VCT F2 = WOOD TO MATCH EXISTING B1 = RUBBER DATE DESCRIPTION C1 = ACOUSTICAL CEILING TILE C2 = GYP BD. PAINTED ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET DRAWN: PBL CHECKED: DGM DATE: 4/10/13 PROJECT #: 12013 SCHEDULES A4.1 ANNE ARUNDEL COUNTY PUBLIC SCHOOLS ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET DRAWN: MS CHECKED: JG DATE: 4/10/13 PROJECT #: 12013 LEGEND ABBREVIATIONS NOTES & DETAILS M1.1 ANNE ARUNDEL COUNTY PUBLIC SCHOOLS ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION ISSUED FOR: KEY PLAN NO SCALE REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET DRAWN: MS CHECKED: JG DATE: 4/10/13 PROJECT #: 12013 FLOOR PLAN NEW WORK M1.2 ABBREVIATION LIST EXISTING TO BE REMOVED EXISTING TO REMAIN SYMBOL LIST GENERAL ELECTRICAL NOTES NEW ANNE ARUNDEL COUNTY PUBLIC SCHOOLS ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION LIGHTING FIXTURE SCHEDULE ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET PROJECT #: DRAWN: 12013 CHECKED: DATE: 4/10/13 ABBREVIATIONS, SYMBOLS,LIGHTING FIXTURES SCHEDULE & GENERAL NOTES E.1 CORRIDOR ANNE ARUNDEL COUNTY PUBLIC SCHOOLS ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 CORRIDOR # DATE DESCRIPTION CORRIDOR CLASS ROOM AUDITORIUM DRAWING NOTES GENERAL NOTES: ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET PROJECT #: DRAWN: 12013 CHECKED: DATE: KEY PLAN NO SCALE 4/10/13 DEMOLITION AND LIGHTING PLAN - PIT, FIRST & SECOND FLOORS E.2 CORRIDOR ANNE ARUNDEL COUNTY PUBLIC SCHOOLS CORRIDOR ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION GENERAL NOTES: ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET PROJECT #: DRAWN: 12013 CHECKED: DATE: KEY PLAN NO SCALE 4/10/13 POWER & SPECIAL SYSTEMS PLAN - PIT, FIRST & SECOND FLOORS E.3 GENERAL NOTES: ANNE ARUNDEL COUNTY PUBLIC SCHOOLS ELEVATOR & RAMP ADDITION TO PHOENIX CENTER FOR Anne Arundel County Public Schools 291 Locust Ave. Annapolis, MD 21401 # DATE DESCRIPTION ISSUED FOR: REVIEW AS-BUILTS BID REVISIONS PERMIT 95% CD SET PROJECT #: DRAWN: KEY PLAN NO SCALE 12013 CHECKED: DATE: 4/10/13 POWER PLAN ELECTRICAL ROOM E.4
© Copyright 2024