6. 7. 8. 9. 10. 11. 12. 13. 14. 15. SAVE-A-LOT FOOD STORES 18. 19. 20. TENANT FIT OUT 2400 BULL STREET, SAVANNAH, GA . 31401. DATE: C "COMPANY NAME" 2010 ALL RIGHTS RESERVED 5. DESCRIPTION: 4. REV. NUMBER: 2. 3. PREMISES ARE TO BE FREE FROM ASBESTOS AND OTHER HAZARDOUS SUBSTANCES AND GASES, ANY SUCH ASBESTOS AND OTHER HAZARDOUS SUBSTANCES AND GASES SHALL BE REMOVED (ACCORDING TO ALL APPLICABLE LAWS) PRIOR TO THE START OF WORK. LANDLORD DELIVERING BUILDING AS-IS. ALL WORK BY SAVE-A-LOT GENERAL CONTRACTOR. DURING THE BIDDING PERIOD, EACH CONTRACTOR SHALL BE HELD RESPONSIBLE TO VISIT THE SITE AND VICINITY TO ACQUAINT THEMSELVES WITH THE EXISTING CONDITIONS, FACILITIES AND OBSTRUCTIONS INVOLVED IN AND EXPECTED BY THE WORK INDICATED BY ALL CONTRACT DOCUMENTS IN ORDER TO PROVIDE A COMPLETE AND ACCURATE BID. CONTRACTOR'S FAILURE TO REASONABLY DETERMINE AND/OR ANTICIPATE THE EFFECT OF EXISTING CONDITIONS AND INVOLVEMENT SHALL NOT BE JUSTIFICATION FOR ADDITIONAL COMPENSATION. PROVIDE" MEANS "FURNISH AND INSTALL." CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OR SAVE-A-LOT PROJECT MANAGER OF DISCREPANCIES. CONTRACTOR HAS SOLE RESPONSIBILITY OF FIELD VERIFYING DIMENSIONS PRIOR TO ORDERING MATERIALS. CONTRACTOR TO COORDINATE NEW SCOPE OF WORK REQUIREMENTS W/ ALL DISCIPLINES WITHIN THIS SET OF DRAWINGS. CONTRACTOR TO INVESTIGATE EXISTING CONDITIONS THOROUGHLY AND IDENTIFY CONFLICTS, IF ANY, AS EARLY AS POSSIBLE DURING CONSTRUCTION IN ORDER TO RESOLVE CONFLICTS AS QUICKLY AS POSSIBLE NOTIFY PROJECT MANAGER OF ANY STRUCTURAL DEFECTS OR CONDITIONS WITHIN THE LEASED PREMISES IF DISCOVERED DURING THE BUILD-OUT OF THE LEASED PREMISES. CONTRACTOR SHALL PROVIDE NECESSARY BARRIERS TO CONTAIN DUST / DEBRIS DURING CONSTRUCTION. CONTRACTOR SHALL REMOVE DEBRIS FROM WORK AREA EACH DAY PRIOR TO LEAVING SITE. CONTRACTOR SHALL PROVIDE FINAL CLEANING OF STORE AT END OF CONSTRUCTION. INCLUDING, BUT NOT LIMITED TO, SALES AREA, OFFICE, BREAK ROOM, REST ROOMS, BACK ROOM AREAS, COOLERS, FREEZERS, STORE FRONT GLAZING AND DOORS. PROVIDE DUST PARTITION TO PROTECT EQUIPMENT AND ADJACENT, NON-WORK AREAS USE ELECTRIC OR PNEUMATIC POWERED EQUIPMENT FOR INTERIOR WORK. DO NOT USE EQUIPMENT THAT PRODUCES EXHAUST FUMES. ALL WOOD, WOOD FRAMING AND WOOD BLOCKING NECESSARY FOR PLUMBING FIXTURES, TOILET ACCESSORIES, TIME-CLOCK, SHELVING, DOOR STOPS, ETC. SHALL BE FIRE RETARDANT WOOD. CONTRACTOR SHALL REMOVE / REPLACE OR USE A FIRE RETARDANT COATING APPLICATION (SUCH AS FLAMEX FS-II) ON ALL NON FIRE-RETARDANT WOOD EXPOSED DURING CONSTRUCTION. VISUALLY INSPECT THE ROOF FOR DAMAGE OR NEED OF REPAIR PRIOR TO BEGINNING ANY WORK ON THE ROOF. IDENTIFY AND PHOTOGRAPH ANY EXISTING DAMAGE OR PROBLEM AREAS, AND REPORT TO SAVE-A-LOT PROJECT MANAGER. CONTRACTOR SHALL PROVIDE NECESSARY CUTTING AND PATCHING AT ALL PENETRATIONS FOR PLUMBING, HVAC AND ROOF HATCH. IN ORDER TO PRESERVE THE ROOFING WARRANTY, THE CONTRACTOR THAT INSTALLED THE ROOF SHOULD PERFORM THE WORK. OTHERWISE, HAVE THE WORK PERFORMED BY A LICENSED ROOFING CONTRACTOR THAT IS APPROVED BY BOTH THE ROOFING MANUFACTURER AND THE LANDLORD. CONTRACTOR SHALL PROVIDE ALL ROOF PENETRATIONS PER NEW REFRIGERATION EQUIPMENT AND ASSOCIATED STRUCTURAL, MECHANICAL AND ELECTRICAL PER MANUFACTURER'S SPECIFICATIONS. SEE DETAILS 15 & 16 / A-4. CONTRACTOR SHALL REPAIR ALL ROOF DAMAGE CAUSED BY EQUIPMENT INSTALLATION, REMOVAL OR RELOCATION. CONTRACTOR SHALL REMOVE ALL DEBRIS FROM ROOF. CONTRACTOR SHALL PROVIDE A SMOOTH, CLEAN AND LEVEL EXISTING CONCRETE FLOOR READY FOR INSTALLATION OF NEW FLOOR FINISHES COOLERS AND FREEZERS ARE FURNISHED N.I.C. AND INSTALLED BY REFRIGERATION CONTRACTOR. CONTRACTOR SHALL COORDINATE REFRIGERATED CASE LOCATIONS w/ SAVE-A-LOT PROJECT MANAGER AND REFRIGERATION DRAWINGS - TYPICAL. CONTRACTOR SHALL PROVIDE AN AS-BUILT, RECORD SET OF DRAWINGS TO SAVE-A-LOT PROJECT MANAGER AT PROJECT COMPLETION. ONE FULL SIZE SET & FULL SET OF PDF FILES ON CD. CERTIFICATION: 1. BY: GENERAL NOTES SHEET INDEX SHT. NO. DESCRIPTION CS-1 COVER SHEET F-1 FIXTURE PLAN - (FOR REFERENCE ONLY) ARCHITECTURAL DRAWINGS A-0 DEMOLITION PLAN A-1 FLOOR PLAN A-2 REFLECTED CEILING PLAN A-3 ENLARGED FLOOR PLANS AND EXTERIOR ELEVATION A-4.1 DETAILS A-4.2 DETAILS A-5 MECHANICAL CODE: 2006 INTERNATIONAL MECHANICAL CODE WITH GA AMENDMENTS. 2006 INTERNATIONAL FUEL GAS CODE WITH GA AMENDMENTS. ELECTRICAL CODE: 2011 NATIONAL ELECTRICAL CODE WITH GA AMENDMENTS. FIRE CODE: 2006 INTERNATIONAL FIRE CODE AND OCGA 120-3-3. ACCESSIBILITY: 1997 GA ACCESSIBILITY STANDARDS. ENERGY CODE : 2009 INTERNATIONAL ENERGY CONSERVATION CODE WITH GA AMENDMENTS. LIFE SAFETY CODE : 2000 NFPA 101 AND OCGA 120-3-3. CONSTRUCTION CLASSIFICATION: --------------------------------5B USE GROUP: ----------------------------------M-MERCANTILE EXISTING SINGLE STORY- NO CHANGE AREA CALCULATIONS: GROUND FLOOR: ------------------------------------------------------------------------17,120 SF NORTH PROJECT DESCRIPTION THIS PROJECT IS A TENANT FIT-OUT / REMODEL OF A PORTION OF A FORMER RETAIL BUILDING. THE WORK WILL INCLUDE INTERIOR FIXTURE / EQUIPMENT MODIFICATIONS / INSTALLATIONS AFTER SUB-DIVIDING THE EXISTING SPACE. MODIFICATIONS TO THE INTERIOR WILL BE MADE FOR INCORPORATION IN THE NEW LAYOUT OF THE SPACE. IN ADDITION, PLUMBING, MECHANICAL, FIRE SPRINKLER SYSTEM AND ELECTRICAL MODIFICATIONS WILL BE REQUIRED TO ACCOMMODATE THE NEW REQUIREMENTS FOR THE PROPOSED GROCERY STORE. ALSO, INCLUDED IN THE REMODEL WILL BE EXTERIOR SIGNAGE AND REPAINTING THE MAIN CANOPY SIGN FACADE. FIRST FLOOR OCCUPANT LOAD: MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT: AREA LOAD FACTOR MERCANTILE (SALES) AREA: 8,725 SF ( / 30) STORAGE / MECHANICAL: 5,165 SF ( / 300) OFFICE: 315 SF ( / 100 PREP: 340 SF ( / 200) ASSEMBLY-UNCONCENTRATED: 205 SF ( /15) TOTAL FIRST FLOOR OCCUPANT LOAD: OCCUPANTS = 291 = 17 = 3 = 2 = 14 = 327 GAS SERVICE CUSTOMER SERVICE, ATLANTA GAS LIGHT COMPANY. PHONE: (800) 427-5463 WEB ADDRESS: www.atlantagaslight.com FIRE MARSHAL CRAIG LANDOLT- FIRE MARSHALL CITY OF SAVANNAH FIRE DEPARTMENT, 121 E. OGLETHORPE AVE., SAVANNAH, GA 31401 PHONE: (912) 644-5960 EMAIL: [email protected] PLANNING DEPARTMENT THOMAS F. BOLTON - ZONING INSPECTOR / PLANS EXAMINER PHONE: (912) 651-6530 EXT 1869 FAX : (912) 525 -1650 EMAIL: [email protected] AND RANDOLPH B. SCOTT - ZONING ADMINISTRATOR. PHONE : ( 912) 651- 6530 EXT 1848 FAX : ( 912) 525-1644 EMAIL: [email protected] DEPARTMENT OF AGRICULTURE DANIEL ESOE - AGRICULTURAL MANAGER, GEORGIA DEPARTMENT OF AGRICULTURE, 19 MLK Jr. DRIVE, ROOM 312, ATLANTA, GA 30334 PHONE: (404) 656-3621 EMAIL: [email protected] ELECTRICAL SERVICE BUSINESS CUSTOMER SERVICE, GEORGIA POWER. PHONE: (888) 655-5888 TELEPHONE SERVICE AT&T PHONE: 1-877-253-0009 TOTAL OCCUPANTS: = 327 EGRESS WIDTH PER OCCUPANT SERVED: REQUIRED: 0.2 MAIN FLOOR: 327 OCCUPANTS x 0.2 EGRESS WIDTH FACTOR = 65.4 INCHES TOTAL REQUIRED: = 65.4 INCHES EXIT WIDTH PROVIDED: 198 INCHES (DIRECT FROM SALES FLOOR) 1- SWINGING DOOR UNIT @ 13'-6" = 162 INCHES 1-SALES EMERGENCY EXIT @ 3'-0" = 36 INCHES I.D. IN. INT. LBS. MAX. MFR. MIN. MAXIMUM TRAVEL DISTANCE - 250 FEET (WHEN FULLY SPRINKLED), (113' ACTUAL) REQUIRED PLUMBING FIXTURES : (2009 UPC WITH ST. LOUIS COUNTY ORDINANCE & AMENDMENTS CHAPTER 4 MERCANTILE, PAGE 88) WATER CLOSETS - 1 FIXTURE PER 200 OCCUPANTS, 325 TOTAL OCCUPANTS (2 MALE, 2 FEMALE) WOMEN: 2 REQUIRED, 1 PROVIDED MEN: 2 REQUIRED, 1 PROVIDED (SEE NOTE #5, PAGE 93 OF CHAPTER 4 AMENDMENT) LAVATORY: WOMEN: 1REQUIRED, 1 PROVIDED MEN: 1 REQUIRED, 1 PROVIDED DRINKING FOUNTAIN: 2 REQUIRED, 2 PROVIDED MOP SINK: 1 REQUIRED, 1 PROVIDED FIRE SAFETY SYSTEMS: SPRINKLER SYSTEM ( EXIST.) YES x NO _ SPRINKLER SYSTEM (EXT. CANOPY) YES _ NO X EMERGENCY LIGHTING & EXIT SIGNS YES X NO _ FIRE ALARM YES X NO _ SMOKE DETECTIONS SYSTEMS YES X NO _ PANIC HARDWARE YES X NO _ FIRE EXTINGUISHERS: YES X NO _ LOCATED IN QUANTITY AND LOCATIONS DIRECTED BY FIRE MARSHAL PROJECT DIRECTORY TENANT ALLEN GREEN SAVE-A-LOT FOOD STORES 3316, QUAIL RIDGE LANE MATTHEWS, NC 28104 PHONE: (704) 956-8497 EMAIL: [email protected] LANDLORD/OWNER JOHN J. RAUERS LAMARA COMPANY 101 BARNARD ST., SUITE 403, SAVANNAH, GA 31401 PHONE: (912) 236-2461 CELL : (912) 429-3900 EMAIL: [email protected] ARCHITECT ANNE WAGNER, LEED AP, NCARB SUPER VALU STORE DESIGN SERVICES EAST VIEW INNOVATION CENTRE (EVIC), 7075 FLYING CLOUD DR, EDEN PRAIRIE, MN 553443307 PHONE: (952) 914-5873 FAX: (952) 914-5850 EMAIL: [email protected] MECHANICAL BOB KRAHN STORE DESIGN SERVICES EAST VIEW INNOVATION CENTRE (EVIC), 7075 FLYING CLOUD DR, EDEN PRAIRIE, MN 553443307 PHONE: (952) 914-5857 FAX: (952) 914-5850 EMAIL: [email protected] STRUCTURAL ENGINEER MARK MIELKE VANSICKLE ALLEN 2955 XENIUM LANE # 10, PLYMOUTH, MN - 55441 PHONE: (763) 577-9120 FAX: (763) 559-6023 EMAIL: mmielkeevaaeng.com ELECTRICAL BRUCE MC NEIL STORE DESIGN SERVICES EAST VIEW INNOVATION CENTRE (EVIC), 7075 FLYING CLOUD DR. EDEN PRAIRIE, MN 55344 PHONE: (952) 914-5843 FAX: (952) 914-5850 EMAIL: [email protected] MISCELLANEOUS MASONRY OPENING MOUNTED MOUNTING NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OUTSIDE DIMENSION OPENING OPPOSITE ORIENTED STRAND BOARD POUNDS PER LINEAL FOOT PROJECT MANAGER (SAVE-A-LOT) POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH REFLECTED CEILING PLAN REFER TO, REFERENCE FROM REINFORCING REQUIRED ROUGH OPENING SIMILAR SPECIFICATIONS STEEL STRUCTURAL SQUARE TONGUE & GROOVE TOP OF CURB/CONCRETE TOP OF TOP OF DRAIN TYPICAL VERTICAL UNIFORM LOAD UNIFORM DISTRIBUTED LOAD WITH WEATHERPROOF WELDED WIRE FABRIC AT DETAIL 101 ROOM NUMBER S-1 STRUCTURAL PLAN S-2 STRUCTURAL NOTES AND DETAILS PLUMBING DRAWINGS P-1 DRAIN, WASTE AND VENT PLAN P-2 WATER & GAS PIPING PLAN P-3 PLUMBING SCHEDULES P-4 PLUMBING DETAILS MECHANICAL DRAWINGS M-1 HVAC PLAN M-2 HVAC SCHEDULES AND DETAILS FIRE PROTECTION FP-1 FIRE PROTECTION PLAN ELECTRICAL DRAWINGS E-0 ELECTRICAL DEMOLITION PLAN E-1 LIGHTING PLAN E-2 POWER PLAN E-3 REFRIGERATION POWER PLAN E-4 ENLARGED POWER PLAN AND DETAILS E-5 RISER DIAGRAM AND SCHEDULES REFRIGERATION DRAWINGS SYMBOL LEGEND XX X-X STRUCTURAL DRAWINGS XXX N EQUIPMENT LIST R-1 UTILITY COORDINATION PLAN (FOR REFERENCE ONLY) R-2 REFRIGERATION SCHEDULE (FOR REFERENCE ONLY) R-3 REFRIGERATION PIPING PLAN & LINE SIZING (FOR REFERENCE ONLY) R-4 REFRIGERATION CONTROL WIRING DIAGRAMS (FOR REFERENCE ONLY) R-5 EQUIPMENT DETAILS (FOR REFERENCE ONLY) R-6 EQUIPMENT CUT SHEETS (FOR REFERENCE ONLY) R-7 EQUIPMENT CUT SHEETS & CASE MISTING SYSTEM (FOR REFERENCE ONLY) R-8 REFRIGERATION WIRE SIZING & DETAILS (FOR REFERENCE ONLY) STORE NUMBER 473 PROJECT NUMBER P03686-01 XX X-X SECTION 116A 07 XX X-X ELEVATION DOOR NUMBER KEY NOTE INDICATOR A 1 COLUMN GRID REVISIONS SHEET TITLE COVER SHEET SHEET NUMBER CS-1 TENANT FIT OUT 2006 INTERNATIONAL PLUMBING CODE WITH GA AMENDMENTS. MISC. M.O. MT'D. MT'G. N.I.C. NO. NTS. O.C. O.D. OPNG. OPP. O.S.B. P.L.F. P.M. P.S.F. P.S.I. R.C.P. RE: REINF. REQ'D R.O. SIM. SPECS. STL. STRUC. SQ. T&G T.C. T.O. T.D. TYP. VERT. U.L. U.D.L. W/ W.P. W.W.F. @ SAVANNAH, GA - 31401 PLUMBING CODE:. ANCHOR BOLT ACOUSTIC CEILING PANEL ABOVE FINISHED FLOOR AND ALUMINUM ARCHITECTURAL BUILDING BOTTOM OF BEARING CENTER LINE CUBIC FEET PER MINUTE CONTROL JOINT CONCRETE MASONRY UNITS COLUMN CONCRETE CONTINUOUS CYLINDER DIAMETER EACH ELEVATION EXTERIOR INSULATING FINISH SYSTEM EXISTING EXTERIOR FOUNDATION FINISHED OPENING FACE OF CURB/CONCRETE FACE OF MASONRY FINISHED FLOOR FEET FOOTING FIRE-RETARDANT GAUGE GALVANIZED GALVANIZED IRON OR STEEL GENERAL CONTRACTOR GLUE LAMINATED STRUCTURE MEMBER GYPSUM BOARD GYPSUM WALL BOARD HEADED CONCRETE ANCHOR HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATING AND AIR CONDITIONING INSIDE DIMENSION INCH INTERIOR POUNDS MAXIMUM MANUFACTURER MINIMUM 04/24/12 2006 INTERNATIONAL BUILDING CODE WITH GA AMENDMENTS. A.B. A.C.P. A.F.F. & ALUM. ARCH. BLDG. B.O. BRG. C.L. CFM C.J. CMU COL. CONC. CONT. CYL. DIA. EA. ELEV. E.I.F.S. EXIST. EXT. FDN. F.O. F.O.C. F.O.M. F.F. FT. FTG. FR. GA. GALV. G.I. G.C. G.L. GYP. BD. GWB. H.C.A. H.D. HORIZ. HR. HT. HVAC DATE: BUILDING CODE: WATER SERVICE / SANITARY SEWER CITY OF SAVANNAH UTILITY SERVICES DEPARTMENT, TOM VANDERHORST, DEPARTMENT HEAD. 132 E. BROUGHTON ST., SECOND FLOOR, SAVANNAH, GA PHONE: (912) 651-6460 2400 BULL STREET, BUILDING DEPARTMENT CITY OF SAVANNAH, GOVERNING MUNICIPALITY, JASON CARANGELO - BUILDING INSPECTIONS ADMINISTRATION, DEVELOPMENT SERVICES DEPARTMENT, 5515 ABERCORN ST., SAVANNAH, GA 31405 PHONE: (912) 651-6530 EMAIL: [email protected] AW BUILDING CODE DATA: ABBREVIATIONS CHECKED: GOVERNMENTAL AGENCIES MG SITE LOCATION CODE / PROJECT DATA DRAWN: SITE MAP DOOR AND ROOM FINISH SCHEDULES AND NOTES
© Copyright 2024