CORRIVEAU CADD FLAT ROOF TRUSSES (BUILT UP ASPHALT ROOF OR BITOMOUS MEMBRANE) FRAMER TO PROV'D SLOPE 1/4" = 1'-0" (FRAMED /W SLEEPERS) NOTE: WINDOW MUNTIN BARS MAY VARY (WINDOW MANUFACTURER TO VERIFY) NOTE: PROV'D ICE AND WATER SHIELD AT ALL VALLEY, DORMER, HIP AND FLAT ROOF CONNECTIONS) DECORATIVE FALSE DORMER DECORATIVE FINIAL 4065 STANLEY AVENUE, UNIT 2 NIAGARA FALLS, ONTARIO (905) 358-5535 12 3'-9" 1'-0" 12 (TYP) FLAT ROOF: - PROV'D BITIMUS MEMBRANE - FLASHING AS PER O.B.C. - SLOPE 1/4" = 1'-0" (REFER TO DETAIL ON SHEET A7) 4'-1" METAL OR COPPER ROOF 12 G I S 15 1'-6" ASPHALT SHINGLES 12 2'-4" FOUNDATION ASSEMBLY DECORATIVE LIMESTONE MOULDING (OWNER TO VERIFY PROFILE) (TYP.) EXPOSED CONC. TO BE PARGED (TYP.) 14" Ø CORINTHIEN DECORATIVE STRUCTURAL COLUMN TO BE ANCHORED TO SLAB (TYP.) - CAST IN PLACE STEP (IF REQ'D) VERIFY DIMS ON SITE - 10" GRANULAR BASE UNDISTURBED SOIL ANCHORED TO CONC. WALL - CAST IN PLACE STEP (IF REQ'D) VERIFY DIMS ON SITE - 10" GRANULAR BASE UNDISTURBED SOIL ANCHORED TO CONC. WALL TOP OF FTG BOT OF FTG FRONT ELEVATION I R R 5.5" SCALE: 1/4" =1'-0" TYPICAL MOLDING PROFILE FOR DOORS / WINDOWS BASIC TRIM SHOWN FOR 3D REGENERATION PUPOSES (OWNER TO VERIFY PROFILE) O R P P Y T R E O F O C E V 1'-8" 40'-6" (MINOR VARIANCE REQUIRED) (31'-10" MAX ROOF HT) TOP OF FND. CUT STONE OR CONC. SILL (TYP.) 4'-2" U A 36" DECORATIVE WROUGHT IRON RAILING H ALL CONTRACTORS AND OR TRADES SHALL VERIFY ALL DIMENSIONS, NOTES, SITE AND REPORT ANY DISCREPENCIES PRIOR TO COMMENCEMENT OF WORK. THIS DRAWING IS NOT TO BE SCALED, ALL DRAWINGS, PRINTS AND RELATED DOCUMENTS ARE THE PROPERTY OF THE DESIGNER AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS AND RELATED DOCUMENTS IN PART OR IN WHOLE IS STRICTLY FORBIDDEN WITHOUT WRITTEN CONSENT. DRAWINGS TO BE USED FOR THE PURPOSE FOR WHICH THEY ARE ISSUED. TOP OF FTG. BOT. OF FTG. 6" STONE FINISH (OWNER TO VERIFY STYLE) (TYP.) O PROV'D 4"x8" CHASE IN FDN (SITE VERIFY HT) PROV'D 4"x8" CHASE IN FDN (SITE VERIFY HT) 30" M TOP OF DBL PLT 1 - MECHANICAL & ELECTRICAL DESIGN BY CONTRACTOR 2 - ALL FLOOR DRAIN LOCATIONS TO BE VERIFIED BY CONTRACTOR 3 - ALL 'B' - VENT LOCATIONS TO BE VERIFIED BY CONTRACTOR 4 - ALL ROOF ATTIC AREAS MUST HAVE ACCESS. 5 - ALL STAIRS TO BE APPROVED BY WAY OF SHOP DRAWINGS PRIOR TO MANUFACTURING. 6 - ALL KITCHEN CABINETS TO BE APPROVED PRIOR TO MANUFACTURING BY WAY OF SHOP DRAWING BYTHE SUPPLIER. 7 - KITCHEN PLAN LAYOUT TO BE APPROVED BY OWNER AND KITCHEN DESIGNER PRIOR TO MANUFACTURING & INSTALLATION. 8 - ALL ELECTRICAL LAYOUT TO BE VERIFIED ON SITE WITH OWNER/BUILDER & CONTRACTOR. 9 - ROOF LAYOUT & GIRDER TRUSS LOCATIONS TO BE VERIFIED BY ROOF TRUSS MANUFACTURER PRIOR TO MANUFACTURING. 8" FIN. FLOOR 11'-3.5" (10'-0" CONC. POUR TO BE ENGINEERED) 1'-6" - LAG BOLT BRICK LINTEL INTO FLOOR - L.V.L. HEADER FOR STONE ABOVE - PROV'D ENG CAST STONE LINTEL IF REQ'D 3'-0" 6'-8" 12'-0" TOP OF TYP. WIN. E ALL TYPICAL CONSTRUCTION SHALL CONFORM TO THE O.B.C. PART 9 (MOST CURRENT EDITION AND AMMENDMENTS) 12'-0" 24" 1'-8" E U/S CLG D LIMESTONE WINDOW TRIM (TYP.) 1'-0" 5'-4" METAL OR COPPER ROOF FIN. 2ND FLOOR 14" BRICK LINTEL ANCHORED TO GIRDER TRUSS 12 (TYP) METAL OR COPPER ROOF 24" DECORATIVE WROUGHT IRON RAILING LIMESTONE FINISH (TYP.) FACE BRICK (TYP.) 9'-0" NOTES: 2'-0" 5'-0" TOP OF DBL PLT 24" 2'-6" TOP OF DBL PLT @ TURRET DECORATIVE COUPOLA (OWNER TO VERIFY STYLE) METAL OR COPPER ROOF 2'-0" 1'-10" 15 /12 15/12 15 /12 18" SOLAR TUBE METAL OR COPPER ROOF N SAMPLE DRAWINGS NEW HOME CONSTRUCTION STEPPED FOOTING (TYP.) NOT TO EXCEED 1:2 RISE TO RUN TO BE ON BEARING SOIL DATE: NO. REVISION: BY CERTIFICATION: NOTE: BACKFILL NOT TO EXCEED 3'-11" (FROM GRADE TO TOP OF SLAB - REFER TO UNLATERALLY SUPPORTED WALL O.B.C - 9.15.4.2 - TABLE - 9.15.4.A (REFER TO GRADING PLAN (SITE CONDITIONS) PRIOR TO POUR - POUR 10" THICK REINF. FND. AS PER ENGINEER SPECS IF REQUIRED ) DR. BY: CH. BY: DATE: SCALE: TITLE: FRONT ELEVATION, 3D PERSPECTIVES SHEET No. 2 OF 9 A2
© Copyright 2024