Document 275987

CORRIVEAU
CADD
FLAT ROOF TRUSSES (BUILT UP ASPHALT ROOF
OR BITOMOUS MEMBRANE) FRAMER TO PROV'D
SLOPE 1/4" = 1'-0" (FRAMED /W SLEEPERS)
NOTE:
WINDOW MUNTIN BARS MAY VARY
(WINDOW MANUFACTURER TO VERIFY)
NOTE:
PROV'D ICE AND WATER SHIELD AT ALL
VALLEY, DORMER, HIP AND FLAT ROOF
CONNECTIONS)
DECORATIVE
FALSE DORMER
DECORATIVE
FINIAL
4065 STANLEY AVENUE, UNIT 2
NIAGARA FALLS, ONTARIO
(905) 358-5535
12
3'-9"
1'-0"
12 (TYP)
FLAT ROOF:
- PROV'D BITIMUS MEMBRANE
- FLASHING AS PER O.B.C.
- SLOPE 1/4" = 1'-0"
(REFER TO DETAIL ON SHEET A7)
4'-1"
METAL OR
COPPER ROOF
12
G
I
S
15
1'-6"
ASPHALT
SHINGLES
12
2'-4"
FOUNDATION ASSEMBLY
DECORATIVE LIMESTONE
MOULDING (OWNER TO
VERIFY PROFILE) (TYP.)
EXPOSED CONC.
TO BE PARGED
(TYP.)
14" Ø CORINTHIEN DECORATIVE
STRUCTURAL COLUMN TO BE
ANCHORED TO SLAB (TYP.)
- CAST IN PLACE
STEP (IF REQ'D)
VERIFY DIMS ON SITE
- 10" GRANULAR BASE
UNDISTURBED SOIL
ANCHORED TO CONC.
WALL
- CAST IN PLACE STEP (IF REQ'D)
VERIFY DIMS ON SITE
- 10" GRANULAR BASE UNDISTURBED
SOIL ANCHORED TO CONC. WALL
TOP OF FTG
BOT OF FTG
FRONT ELEVATION
I
R
R
5.5"
SCALE: 1/4" =1'-0"
TYPICAL MOLDING PROFILE
FOR DOORS / WINDOWS
BASIC TRIM SHOWN FOR 3D
REGENERATION PUPOSES
(OWNER TO VERIFY PROFILE)
O
R
P
P
Y
T
R
E
O
F
O
C
E
V
1'-8"
40'-6" (MINOR VARIANCE REQUIRED)
(31'-10" MAX ROOF HT)
TOP OF FND.
CUT STONE OR
CONC. SILL (TYP.)
4'-2"
U
A
36" DECORATIVE
WROUGHT IRON RAILING
H
ALL CONTRACTORS AND OR TRADES SHALL VERIFY ALL DIMENSIONS,
NOTES, SITE AND REPORT ANY DISCREPENCIES PRIOR TO
COMMENCEMENT OF WORK. THIS DRAWING IS NOT TO BE SCALED, ALL
DRAWINGS, PRINTS AND RELATED DOCUMENTS ARE THE PROPERTY OF
THE DESIGNER AND MUST BE RETURNED UPON REQUEST.
REPRODUCTION OF DRAWINGS AND RELATED DOCUMENTS IN PART OR IN
WHOLE IS STRICTLY FORBIDDEN WITHOUT WRITTEN CONSENT.
DRAWINGS TO BE USED FOR THE PURPOSE FOR WHICH THEY ARE ISSUED.
TOP OF FTG.
BOT. OF FTG.
6"
STONE FINISH (OWNER
TO VERIFY STYLE) (TYP.)
O
PROV'D 4"x8" CHASE IN FDN
(SITE VERIFY HT)
PROV'D 4"x8" CHASE IN FDN
(SITE VERIFY HT)
30"
M
TOP OF
DBL PLT
1 - MECHANICAL & ELECTRICAL DESIGN BY CONTRACTOR
2 - ALL FLOOR DRAIN LOCATIONS TO BE VERIFIED BY CONTRACTOR
3 - ALL 'B' - VENT LOCATIONS TO BE VERIFIED BY CONTRACTOR
4 - ALL ROOF ATTIC AREAS MUST HAVE ACCESS.
5 - ALL STAIRS TO BE APPROVED BY WAY OF SHOP DRAWINGS
PRIOR TO MANUFACTURING.
6 - ALL KITCHEN CABINETS TO BE APPROVED PRIOR TO
MANUFACTURING BY WAY OF SHOP DRAWING BYTHE SUPPLIER.
7 - KITCHEN PLAN LAYOUT TO BE APPROVED BY OWNER AND
KITCHEN DESIGNER PRIOR TO MANUFACTURING & INSTALLATION.
8 - ALL ELECTRICAL LAYOUT TO BE VERIFIED ON SITE WITH
OWNER/BUILDER & CONTRACTOR.
9 - ROOF LAYOUT & GIRDER TRUSS LOCATIONS TO BE VERIFIED BY
ROOF TRUSS MANUFACTURER PRIOR TO MANUFACTURING.
8"
FIN.
FLOOR
11'-3.5"
(10'-0" CONC. POUR
TO BE ENGINEERED)
1'-6"
- LAG BOLT BRICK LINTEL INTO FLOOR
- L.V.L. HEADER FOR STONE ABOVE
- PROV'D ENG CAST STONE LINTEL IF REQ'D
3'-0"
6'-8"
12'-0"
TOP OF
TYP. WIN.
E
ALL TYPICAL CONSTRUCTION SHALL
CONFORM TO THE O.B.C. PART 9 (MOST
CURRENT EDITION AND AMMENDMENTS)
12'-0"
24"
1'-8"
E
U/S CLG
D
LIMESTONE
WINDOW
TRIM (TYP.)
1'-0"
5'-4"
METAL OR
COPPER ROOF
FIN. 2ND
FLOOR
14"
BRICK LINTEL
ANCHORED TO
GIRDER TRUSS
12 (TYP)
METAL OR
COPPER ROOF
24" DECORATIVE
WROUGHT IRON RAILING
LIMESTONE
FINISH (TYP.)
FACE BRICK (TYP.)
9'-0"
NOTES:
2'-0"
5'-0"
TOP OF
DBL PLT
24"
2'-6"
TOP OF DBL PLT
@ TURRET
DECORATIVE COUPOLA
(OWNER TO VERIFY STYLE)
METAL OR
COPPER ROOF
2'-0"
1'-10"
15
/12
15/12
15
/12
18" SOLAR TUBE
METAL OR
COPPER ROOF
N
SAMPLE DRAWINGS
NEW HOME
CONSTRUCTION
STEPPED FOOTING (TYP.)
NOT TO EXCEED 1:2 RISE TO
RUN TO BE ON BEARING SOIL
DATE:
NO.
REVISION:
BY
CERTIFICATION:
NOTE:
BACKFILL NOT TO EXCEED 3'-11" (FROM GRADE TO
TOP OF SLAB - REFER TO UNLATERALLY
SUPPORTED WALL O.B.C - 9.15.4.2 - TABLE - 9.15.4.A
(REFER TO GRADING PLAN (SITE CONDITIONS)
PRIOR TO POUR - POUR 10" THICK REINF. FND. AS
PER ENGINEER SPECS IF REQUIRED )
DR. BY:
CH. BY:
DATE:
SCALE:
TITLE:
FRONT ELEVATION,
3D PERSPECTIVES
SHEET No.
2 OF 9
A2