Ver.1.0 1409 FS 700 Pro FS-700 Pro Non-contact infrared thermometer IMPORTANT MEASUREMENT POINT Aim at the Temple area or behind the ear lobe correctly Or Temple area Behind the ear lob Incorrect measurement If there is sweat on the forehead, recommend to measure behind ear lobe. 2~3 cm away from forehead. 2~3cm Wipe off any forehead perspiration and push back the hair from the forehead before taking the temperature. Wipe off any forehead perspiration 2 Push back the hair Non-contact infrared thermometer FS-700 Pro Do not measure temperature near the stove or air-conditioner. Do not use outdoors. If there is a significant change in ambient temperature allow both the thermometer and the patient to adjust for at least 30 minutes before taking the patient’s temperature. WAIT 30 MINITES 3 FS-700 Pro Non-contact infrared thermometer Table of Contents 01. About Body Temperatures 02. Brief introduction of product 03. Simple operation principle 04. Product features 05. User precautions 06. Product Description 07. Before first use 08. Switching on and setting the thermometer > 8-1. Setting the measurement unit(℃/℉) > 8-2. Setting the measurement sound 09. Measuring body temperature 10. Displaying stored measurements 11. Error messages 12. Battery Replacement 13. Maintenance and Storage 14. Safety 15. Product Specifications 16. Warranty 4 5 8 8 8 9 10 11 11 12 13 15 16 17 18 20 26 Non-contact infrared thermometer FS-700 Pro 1. About Body Temperatures What is body temperature? Body temperature is the internal heat level of the human body. Normal temperature is the body temperature of healthy people. This slightly varies within certain limits. The body temperature can vary according to environment, time and activities. For example, a person’s body temperature can be 0.5°C higher at night time than early in the morning. Body temperature control The central nerve in the brain’s hypothalamus controls the body temperature, maintaining a certain level. When body temperature goes up, blood vessels on the inside of the skin expand, causing sweat to be released from the sweat gland, resulting in great losses of heat. Body Temperature Measurement Ranges Normal ranges by site: Axillary : Oral : Rectal : Thermofinder(Forehead) : 94.5 – 99.1 ⳅ 95.9 – 99.5 ⳅ 97.9 – 100.4 ⳅ 96.8 – 100.2 ⳅ 34.7 – 37.3 Ⳅ 35.5 – 37.5 Ⳅ 36.6 – 38.0 Ⳅ 36.0 – 37.9 Ⳅ References: > Chamberlain, J.M., Terndrup, T.E., New Light on Ear Thermometer Readings Contemporary Pediatrics,March 1994. > Keith R. Powell, M.D., Dr. Noah Miller Chair of Pediatrics, Childrens Hospital Medical Center of Akron, and Professor and Chair of Pediatrics, Northeastern Ohio Universities College of Medicine. > Based on survey of pediatricians and general practitioners in UK, France, Germany. GfK Custom Research France, 2009 5 FS-700 Pro Non-contact infrared thermometer Celsius 36 36.5 37 37.5 38 Normal Fahrenheit 96.8 97.7 98.6 38.5 39.5 100.4 101.3 What is fever? Normally, when bacterial, virus, or other pathogens attack the body, fever occurs. Other reasons can be tissue damage or blood diseases like burns and myocardial infarction. An elevated temperature or fever is often viewed as a danger sign. A fever can be beneficial and helps our immune system work more effectively. Infants body temperature Infants cannot sufficiently control body temperature and environment temperature affects them. If indoor temperature is high, the infant’s body temperature rises and vice versa. It is important to measure infant’s body temperatures regularly. > Normal temperatures can be checked by calculating the average value for several days at regular hours in the morning and evening. Infant’s body temperature can show changes about 0.5Ⳅ according to the surrounding temperature. For example, when temperatures for 8 A.M. is 36.7Ⳅ and 8 P.M is 37.3Ⳅ, the normal temperature range is 36.7Ⳅ to 37.3Ⳅ and the normal temperature is 37Ⳅ Fever occurs when body temperature rises 1Ⳅ compared to normal temperature. > Recommended indoor temperature: 24°C to 26°C Recommended humidity: 40% to 60% 6 Non-contact infrared thermometer FS-700 Pro > Infant should not be covered with swaddles and placed on heated floors during summer. If malaria occurs or if body temperature increases too high, it can cause dehydration or fever. In worst cases, it can cause coma or cramps. Using thermofinder (FS-700pro) - Be careful not to get water on the thermometer. 7 FS-700 Pro Non-contact infrared thermometer 2. Brief introduction of product This product is a Non-Contact IR Thermometer Thermofinder safely measures body temperature without contacting the skin. Thermofinder measures body temperature in less than 2 seconds. Carefully read the manual before using the product. 3. Simple operating principle When your body is hot, you touch your forehead, because body temperature is reflected on the forehead. Thermofinder measures infrared energy radiated from the forehead via a sensor. Once it has analyzed the amount of IR energy, it converts it to a temperature value. Thermofinder is a contactless type of thermometer which allows the user to measure body temperature about 2 to 3 cm away from the forehead, thereby decreasing the possibilities of infections or discomfort resulting from contact. 4. Product features Backlit digital LCD display 8 Non-contact infrared thermometer FS-700 Pro It can store up to 32 results. Contactless measurement. Simple design making it easier to use for those with small hands. Power-saving: Automatic shut off after a minute. Powered by two AAA type alkaline batteries. 5. User precautions Thermofinder body temperature measurements do not represent doctor’s consultation or examination Examine the product periodically Read the instructions before initial use If product is damaged or malfunctions contact the dealer or HuBDIC There are no user serviceable parts in the Thermofinder The warranty is valid only when HuBDIC trained personnel service the Thermofinder > Ensure that children do not use this device unsupervised some parts are small enough to be swallowed. > Do not drop the thermometer. It can cause malfunctioning. > Do not insert any foreign materials inside the probe as this will cause malfunction. 9 FS-700 Pro Non-contact infrared thermometer 6. Product Description 1 2 3 8 6 7 5 4 1 LCD display 2 Start button 3 Sound boutton Buttons 4 MODE button 5 MEM button 6 Strap position 7 Probe 8 Battery cover Functions Switching the device on. Starting temperature measurement. Setting the acoustic signal (On/Off). Setting the measurement method. Displaying stored measurements (max 32). Setting the measurement units (Ⳅⳅ). Display Meaning In body temperature mode. In object temperature mode. Memory mode. Change the batteries immediately. 10 Non-contact infrared thermometer FS-700 Pro 7. Before first use Before first use, insert the batteries supplied. > 12.Battery Replacement [page.16] 8. Switching on and setting the thermometer Press the Start button or Mode button briefly. > The device switches on. After two seconds, the display shows that the device is ready for use. > The device always starts in body temperature mode. 8-1. Setting the measurement unit Press the Mode button and MEM button simultaneously for at least 3 to 4 seconds. > The device switches to the other measurement unit. > Possible measurement units : Celsius Ⳅand Fahrenheit ⳅ 8-2. Setting the measurement sound Press the Sound button briefly. > Each time the button is pressed, the sound switches on or off. > If the display shows after pressing the button, the device emits sound. > If the display shows after pressing the button, the device does not emits sound. > This setting is not stored. The next time the device is switched on, the sound is reset to. 11 FS-700 Pro Non-contact infrared thermometer Normal .FBTVSFSNFOUQPJOU Site of measurement recommended is the temple area Sweating .FBTVSFSNFOUQPJOU behind the ear lobe beh References : Greene DS, Fleisher GR. Accuracy of a noninvasive temporal artery thermometer for use in in fants, Arch Pediatr Med 2001 Mar 12 Non-contact infrared thermometer FS-700 Pro Temperature readings may vary according to measurement site. Take multiple measurements at different sites on the forehead (temple area) and use the highest. The temperature will be displayed on the LCD screen and automatically stored. The LCD display is backlit for a period of 2 to 3 seconds. LED 2 Colors Green : measurement range. ⳄUPⳄⳅUPⳅ Red : The temperature of the measuring point is above/below the measurement range. The device temperature is outside the operating temperature range. ⳄUPⳄⳅUPⳅ 10. Displaying stored measurements The device automatically stores the last 32 measurements. Press the Start button or Mode button briefly. > The Thermofinder switches on. After 2 seconds the display indicates the Thermofinder is ready for use Press the MEM button briefly. > The most recent measurement is displayed. 13 FS-700 Pro 14 Non-contact infrared thermometer Non-contact infrared thermometer FS-700 Pro 11. Error messages Display Error description Trouble-shooting The device temeperature is outside the operating temperature range. Operating temperature approx. ⳄUPⳄ ⳅUPⳅ The temeperature of the measuring Measurement range for point is above the measurement range. body temperature : 22ⳄUPⳄ ⳅUPⳅ Measurement range for The temeperature of the measuring point is below the measurement range. object temperature : 10ⳄUPⳄ ⳅUPⳅ The batteries are weak. Change batteries. Display appears briefly after changing the batteries. NOTE When exposed to temperatures between 15°C and 20°C (59°F and 68°F), the forehead temperature may lower due to the influence of the ambient temperature. 15 FS-700 Pro Non-contact infrared thermometer 12. Battery Replacement The device requires two AAA(LR03) batteries. > Open the battery compartment by sliding down the battery compartment lid on the back of the Thermofinder. Take the used batteries out of the battery compartment. Insert new batteries. >Make sure that the batteries are inserted correctly Close battery compartment. > Used batteries should not be disposed of in normal household waste > Dispose of batteries in accordance with national regulations >Remove batteries if the Thermofinder is not likely to be used for some time. >Storage and transport conditions: -20°C to 50°C >The Thermofinder, accessories and batteries are to be disposed of safely and national regulations for disposal must be observed. 16 Non-contact infrared thermometer FS-700 Pro 13. Maintenance and Storage The Sensor component of the Thermofinder is very sensitive and must be kept clean. Do not use if damaged. Do not put any foreign materials inside the probe. To clean the sensor, use a cotton swab with methyl alcohol and carefully wipe the surface clean. The Thermofinder should be stored in a clean indoor environment, free from dust and pollutants and away from direct sun light. If the Thermofinder requires repairs, contact the dealers or HuBDIC. Do not subject the thermometer to strong shocks, such as dropping the unit on the floor. Do not submerge the device or any of the components in water or any other solutions. Store the thermometer and the components in a clean, safe location. Do not modify this thermometer without authorization of the manufacturer. Do not disassemble or attempt to repair the unit or components. 17 FS-700 Pro Non-contact infrared thermometer 14. Safety Readings should not be substituted for medical examinations. For infant and child measurement be sure to hold the child still. Movement can result in an inaccurate reading. Do not modify, disassemble and/or repair the Thermofinder under any circumstances. This will void the warranty. If thermometer is not in use for a long period of time, remove battery from device and store device in a safe place. Store used batteries separately. NOTE ASTM laboratory accuracy requirements in the display range of 22 to 40Ⳅ(71.6ⳅ to 104.0ⳅ) for IR thermometers is ±0.3Ⳅ(±0.5ⳅ). 18 Non-contact infrared thermometer FS-700 Pro > Type of protection against electric shock: Internally Powered equipment. > Degree of protection against electric shock: Type BF applied parts. > Classification according to the degree of protection against ingress of water as detailed in the current edition of IEC 60529: IP22, ordinary equipment. > This equipment is not suitable for use in the presence of flammable anesthetics or oxygen. > Mode of operation: continuous operation. This equipment has been tested and found to comply with the limits for medical devices in IEC/EN 60601-1-2:2007. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving device. - Increase the separation between the equipment. - Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected. - Consult the manufacturer or field service technician for help. 19 FS-700 Pro Non-contact infrared thermometer 15. Product Specifications Measuring point Forehead: Temple area. Alternatively behind the ear lobe. 2 to 3 cm from the measuring point ⳅⳅ_ⳅ ⳅ 20 ⳅ Non-contact infrared thermometer FS-700 Pro Item Screen type Details of description Liquid crystal display(mono LCD) Display Body temperature mode,Memory location, Low Battery, Ⳅⳅdegree,Hi / Lo signs for the temperature outside the measurable ranges Button Start, Sound, Mode, Memory Backlight Turns on for 3 seconds after measurement. Turns off automatically Power-saving Thermofinder turns off automatically after one minute Components FS-700 1set, Manual, Battery(AAA type) 2ea Power 3V ( AAA 1.5V Battery 2 EA ) Measurable numbers More than 5,000 times Size 152mm(W) x 36mm(D) x 37mm(H) Weight 68g (without batteries) Origin Republic of Korea 21 FS-700 Pro 22 Non-contact infrared thermometer Non-contact infrared thermometer FS-700 Pro 23 FS-700 Pro 24 Non-contact infrared thermometer Non-contact infrared thermometer FS-700 Pro 25 FS-700 Pro Non-contact infrared thermometer 16. Warranty Warranty period is one year after the original purchase. Defective products will be repaired or replaced free of charge within the warranty period. Damage due to user carelessness is not covered under this warranty Service period will not be extended after repair If repaired by any unauthorized personnel/technician, warranty is void Product IR FOREHEAD THERMOMETER Purchasing date 20 . Customer Information Name . . Model FS-700pro Phone Address Manufactured By B-301, Taekwang-industrial Building, 191-1, Anyang 7-dong, Manan-gu, Anyang-si, Gyeonggi-do, Korea (zip 430-815) Service Call : +82-1644-3375 http://www.hubdic.com Independence Health, a division of Independence Energy Corp. 3020 Old Ranch Parkway, Suite 300, Seal Beach, CA 90740 USA 26 Non-contact infrared thermometer FS-700 Pro EN ISO 13485:2012, ISO 9001:2008,ISO 14971:2012,IEC 60601-1: 2005, ASTM E1965-98:2003,EN 60601-1-2: 2007, IEC 60601-1-6:2010,IEC 60601-1-11: 2010, IEC 62366: 2007,IEC 60601-1-6: 2010,EN ISO 15223-1:2012,EN 1041:2013,EN 62304:2006 27
© Copyright 2024