COURTESY LIGHT MODIFICATION STANDARD OPERATORS 71-2954029 APPLICATION REQUIREMENTS This wiring modification is for standard mechanical operators models T, GT, J, H, GH, SD, GSD, DJ and DH. 115 Vac is required for the light. Not for use on logic operators. FUNCTIONS This modification provides a light socket on the operator control enclosure. The light will turn on when the door starts to open. It will remain on for several minutes, similar to the courtesy light in a residential garage door opener. INSTALLATION 1. Disconnect power to the operator. 2. Make sure the provided contact blocks fit the contactor. Install the contact blocks on top of the contactor. Carefully bend the wires that are located on top of the contactor out of the way and ensure the connectors do not touch any adjacent terminals. 3. Connect the 4" black wire across terminals 61 on the open and closed contactor (Figure 1). 4. Connect the orange wire from the open #62 auxiliary contact to the CR relay (Figure 1). The CR relay has one remaining coil terminal adjacent to the white wire; connect the orange wire to this corner terminal (Figure 1). 5. Connect the red wire from the closed contactor #62 to the transformer’s wire nut (on most operators radio terminal R3 on the outside of the electrical box can also be used instead of the wire nut) (Figure 1). 6. Connect the gray wire from 5 on the terminal strip to #5 in the operator (Figure 2). 7. Connect the long white and black wires to L1 and L2 (Figure 1). NOTE: Step 7 is valid only on 115V operators (For other voltages a 115 V is required). To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing light delay kit. CARTON INVENTORY DESCRIPTION Auxiliary contact block Nut ½" Lock nut 8-32 Screw 8-32 -10T Wire nut Cable ties Black wire 11" White wire 11" Orange wire 13" Black wire 4" Red wire 13" Gray wire 12" Light module Light socket with nut QTY 2 1 2 2 1 3 1 1 1 1 1 1 1 1 FIGURE 2 Existing Transformer in Operator FIGURE 1 5 A (Or Can be Connected to R3 Radio Terminal) 5 L1 W BK A BK 24Vac DPDT 115V Light OR O BK C Auxiliary L2 Contact Blocks L1 Red Wire From Auxiliary Contact Block to be Connected to Wire Nut in Operator CR BK Wire Nut CR 61 62 L2 115V 24Vac Sec. Timer 61 115V Light 5 (Existing in Operator) GY 62 To Be Connected to Terminal 5 in Operator W R The Timer is Adjustable in One Second Increments From 1 to 1,023 Seconds Red 8. Locate an area inside the electrical box suitable for installing the light socket and timer module. If necessary, drill and mount the light socket and delay module. 9. Connect the light wires to terminals A and L2 (Figure 3). NOTE: It may be necessary to lengthen the wires from the socket to the delay module. 10. Reconnect power to the operator. DO NOT EXCEED 100 TOTAL WATTS. FIGURE 3 To L2 WH Bulb 100 Watts Maximum BK Extra Nut Socket with Nut To A 01-12015 © 2009, The Chamberlain Group, Inc. All Rights Reserved
© Copyright 2024