Ceiling and Wall Enclosures for Securing Aruba Networks Wireless Access Points

Designed to Protect Your
Aruba Networks
Wireless AP and Telecom Enclosures
Investment
Ceiling and Wall Enclosures for Securing
Aruba Networks Wireless Access Points
Physical security
Ideal mounting
orientation
Simplify moves,
adds, and changes
Oberon’s RF-Transparent
Your Aruba Networks access point is an investment in mission critical wireless
networking. Oberon access point enclosures and mounts provide a means
to “lock down” the installation, thereby protecting the integrity of the site
survey, design, and system verification. Oberon’s products provide the physical
security required in government, education, and retail environments and an
aesthetic, professional appearance required in many enterprise installations.
In healthcare environments, Oberon’s products simplify compliance with
infection control procedures by permitting access to the access point without
lifting ceiling tiles and opening the plenum space.
Oberon’s products make planning, maintaining, and growing your secure
wireless network easier than ever. Please visit the Oberon website at www.
oberonwireless.com to find additional suspended ceiling, hard-lid, wall
mount, and NEMA enclosures for Aruba Networks access points.
Oberon is the only approved manufacturer of Wireless LAN access point
enclosures and mounting solutions within the Aruba Networks Ecosystem.
This program assures users that Oberon’s products have been tested for fit and
function with Aruba Networks wireless products. For more information on
Oberon and the Aruba Networks Ecosystem visit http://www.arubanetworks.
com/aruba-partners/ecosystem-partners/enclosures-power-andaccessories/.
ABS plastic doors are
invisible to wireless signals.
See our full line at
oberonwireless.com
Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867-2312 ● Fax (814) 867-2314 ● www.oberonwireless.com
Model 1066‐00 Suspended Ceiling Access Point Mount The Model 1066‐00 wireless access point ceiling mount is designed to provide a secure, convenient, and aesthetic mounting solution for the Aruba Networks AP‐135 series 802.11n access points. This aesthetic, white powder coated steel 2’ x 2’ ceiling tile‐like mount locks the access point in place with a patent pending locking mechanism. Access point moves, adds, and changes can be performed without removing the mount from the ceiling. No ceiling tile cuts are required for installation. The Model 1066‐T features a 3/8’’ bevel in the flange around the perimeter, to match “tegular” ceiling tiles commonly used in new construction and renovations. Model 1066‐00 shown with Aruba Networks AP‐135 series Wireless Access Point (not included) Specifications: 







Economical ceiling mount designed specifically for aesthetic, secure mounting of the Aruba Networks AP‐135 series 802.11n wireless access points Designed to meet NEC300‐22 and 300‐23 for plenum installations OSHPD approved OPA # 1638 Construction: 18 ga. textured white powder‐coated steel flange, 16 ga. aluminum backbox Patent pending locking mechanism, keyed alike, secures Access Point into the ceiling mount Size: 2’ x 2’ x 2¼” deep Weight: 6lbs (not including access point) Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1066‐00 Includes: 



(4) Suspension (hanger) wires (1) ¾” Trade size conduit connector for data/power cable Security hasp to secure mount to ceiling system or other permanent fixture Mounting Instructions
Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com BIM, CAD, and CSI Specifications
Model 1068-00
Suspended Ceiling Access Point Mount
Oberon’s Model 1068-00 universal wireless access point ceiling mount is designed to provide a secure,
convenient, and aesthetic mounting solution for most vendors wireless access points. This aesthetic, white
powder coated steel 2’ x 2’ ceiling tile-like mount locks the access point in place with a patent pending locking
mechanism. The access point is attached to a vendor model specific mounting plate, and the mounting plate is
locked in place into the ceiling tile. Access point moves, adds, and changes can be performed without
removing the mount from the ceiling. No ceiling tile cuts are required for installation.
Model 1068-00 shown without wireless Access Point and with Aruba Network’s AP135
Specifications:
•
•
•
•
•
•
•
•
•
Locking ceiling mount designed for secure, aesthetic, low profile mounting of most vendor’s wireless
access points
UL Listed and designed to meet NEC paragraphs 300-22 and 300-23 for plenum installations
OSHPD approved OPA # 1638
Construction: 18 ga. textured white powder-coated steel flange, 16 ga. aluminum backbox
Patent pending locking mechanism, keyed alike, secures access point into the ceiling mount
Size: 2’ x 2’ x 2” deep. Fits into standard (U.S.) suspended ceiling systems.
Weight: 10.5 lbs (not including access point)
Mount must be supported by the building structure independent of the suspended ceiling, per NEC
paragraph 300.11
Contact your Oberon representative for the vendor specific mounting plates required. Plates are
available for leading wireless access points. Plates sold separately.
Model 1068-00 Includes:
•
•
•
(1) cable egress fire block kit (¾” Trade size conduit connector and fire block foam insert)
(4) Hanger wires
Mounting Instructions
Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867-2312 ● Fax (814) 867-2314 ● www.oberonwireless.com
Model 1052‐AP135 BIM, CAD, and CSI Specifications Suspended Ceiling Enclosure Oberon’s Model 1052‐AP135 wireless LAN access point enclosure is a locking, 2’ x 2’ ceiling tile enclosure designed specifically to conveniently mount and secure the Aruba Networks AP‐135 wireless access points. The enclosure is based on Oberon’s popular 1052‐00 universal wireless access point enclosure, with a door designed specifically for Aruba Networks AP135 wireless access point. No ceiling tile cuts are required for installation. Just mount the access point into the door, place the ceiling tile enclosure in the ceiling, secure the enclosure to the ceiling support structure, and the access point is conveniently and aesthetically secured in the ceiling. Upgrades to different styles of access points are achieved by simply unlocking and replacing the door. 1) Model 1052‐AP135 shown with Aruba Networks AP135 access point (not included) 2) Exploded view of the door, access point, and bracket Specifications: 







Ceiling tile enclosure specifically designed for Aruba Networks AP‐135 access points UL listed and designed to meet NEC300‐22 and 300‐23 for plenum installations OSHPD approved OPA # 1638 Construction: Textured white powder‐coated steel, 16 ga. backbox, 14 ga. door Fully hinged locking door, keyed alike. Door can be replaced to migrate to new access points. Size: Flange is 2’ x 2’, AP Enclosure is 12.5" x 12.5 " x 4.5" deep Weight: 13lbs (not including access point or antenna) Enclosure must be supported by the building ceiling structural system, not the tile gridwork. Model 1052‐AP135 Includes: 



Access point mounting screws (4) Suspension wires (2) ¾” Trade conduit connectors for power and data cable openings in the back‐box Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1020‐RAP5 Compact NEMA Enclosure for Wireless APs The Model 1020‐RAP5 is a compact NEMA 4 enclosure designed to protect Aruba Networks RAP5 and other wireless LAN access points and routers in challenging environments. This rugged polycarbonate enclosure protects the access point from weather, dust, and impacts, and is transparent to wireless signals, so access points and routers with body integrated antennas or small detachable antennas may be protected. Model 1020‐RAP5 shown with Aruba Networks RAP5 Wireless Router and clear cover Specifications: 






Designed to IP66 of IEC 529 and NEMA 1, 2, 4, 4X, 12,and 13 specifications UV stabilized and UL listed (UL 94‐HB flammability rating) light gray polycarbonate back box, clear or light gray cover. (Specify 1020‐RAP5‐CL for clear cover) Transparent to wireless signals Cover attaches with six M‐4 stainless steel screws, silicon sponge gasket material provides seal Cover screws must be torqued to 8 in‐lb Size: 11.8” x 9.1" x 3.4” deep Weight: 3lbs Model 1020‐RAP5 Includes:  (1) Universal mounting plate  (4) Mounting feet  Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1032‐00 “Hard‐Lid” Ceiling or Wall Mount Enclosures Oberon’s Model 1032‐00 “hard lid” or wall mount enclosure provides a secure, aesthetic, convenient mounting solution for smaller wireless access points from many vendors. This economical enclosure has a low profile impact resistant ABS dome so that wireless access points with integrated or non‐detachable antennas can be secured in otherwise “unsecured” spaces. The product is designed to provide an unobtrusive mounting solution. Locks are “keyed‐alike” to simplify moves, adds, and changes. Specifications: 






Wireless access point enclosure designed to be surface mounted on “hard‐lid” ceilings or walls. Economical solution for securing smaller wireless access points with integrated or non‐detachable antennas Cover is UL 94‐5VA Classified ABS Plastic Construction: 16 gauge, powder coated steel back‐box, and impact resistant, RF transparent, ABS cover Size: 11" x 11" x 2.5" (total depth) Weight: 4 lbs (not including access point) Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1032‐00 Includes: 



(2) Keys for lock Mounting Instructions (4) # 6‐32 x 3/16 Screws (4) # 8‐32 x 3/16 Screw Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1032‐C BIM, CAD, and CSI Specifications “Hard‐Lid” Ceiling or Wall Mount Enclosures Oberon’s Model 1032‐C “hard lid” or wall mount enclosure provides a secure, aesthetic, convenient mounting solution for smaller wireless access points from many vendors. This economical enclosure has an impact resistant, clear, lockable polycarbonate cover so that wireless access points with integrated or non‐detachable antennas can be secured in otherwise unsecured spaces. The product is designed to provide an unobtrusive mounting solution. Locks are keyed‐alike to simplify moves, adds, and changes. Model 1032‐C shown with Aruba Networks AP 135 (not included). Specifications: 





Wireless access point enclosure designed to be surface mounted on “hard‐lid” ceilings or walls. Economical solution for securing smaller wireless access points with integrated or non‐detachable antennas, from most vendors Construction: 16 gauge, powder coated steel back‐box. Cover is clear, UL 94‐V2 classified, impact resistant, RF transparent, polycarbonate plastic Fully hinged lockable, ventilated cover Size: 11" x 11" x 4.4" (total depth) Weight: 4.5 lbs (not including access point) Model 1032‐C Includes: 



(2) Keys for lock Mounting Instructions (4) # 6‐32 x 3/16 Screws (4) # 8‐32 x 3/16 Screw Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1052‐AP105 Suspended Ceiling Enclosure Oberon’s Model 1052‐AP105 wireless LAN access point enclosure is a locking, 2’ x 2’ ceiling tile enclosure designed specifically to conveniently mount and secure the Aruba Networks AP‐105 wireless access points. The enclosure is based on Oberon’s popular 1052‐00 universal wireless access point enclosure, with a door designed specifically for Aruba Networks AP105 wireless access point. No ceiling tile cuts are required for installation. Just mount the access point into the door, place the ceiling tile enclosure in the ceiling, secure the enclosure to the ceiling support structure, and the access point is conveniently and aesthetically secured in the ceiling. Upgrades to different styles of access points are achieved by simply unlocking and replacing the door. 1) Model 1052‐AP105 shown with Aruba Networks AP105 access point (not included) 2) Exploded view of the door, access point, and bracket Specifications: 







Ceiling tile enclosure specifically designed for Aruba Networks AP‐105 access points UL listed and designed to meet NEC300‐22 and 300‐23 for plenum installations OSHPD approved OPA # 1638 Construction: Textured white powder‐coated steel, 16 ga. backbox, 14 ga. door Fully hinged locking door, keyed alike. Door can be replaced to migrate to new access points. Size: Flange is 2’ x 2’, AP Enclosure is 12.5" x 12.5 " x 4.5" deep Weight: 13lbs (not including access point or antenna) Enclosure must be supported by the building ceiling structural system, not the tile gridwork. Model 1052‐AP105 Includes: 



Access point mounting screws (4) Suspension wires (2) ¾” Trade conduit connectors for power and data cable openings in the back‐box Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 38‐52‐AP135 BIM, CAD, and CSI Specifications Adaptor Door Oberon’s Model 1052‐00 wireless LAN access point enclosure is a locking 2’ x 2’ ceiling tile enclosure originally designed for the Cisco 1242, Cisco 1232, and Aruba Networks AP‐70 access points. For customers making the migration to the Aruba Networks AP135 802.11n wireless access point, Oberon has designed the 38‐52‐AP135 adaptor door so that customers may install the new access point in the existing enclosure without removing the enclosure from the ceiling. The upgrade simply requires that the existing 1052‐00 door is removed (three interior nuts), the new access point is attached to the adaptor door, and the adaptor door is attached to the enclosure. The upgrade maintains the enclosure’s UL 50 design criteria, and provides the same level of physical security as previously provided. Upgrades are performed without accessing the air handling space above the ceiling. 1) Model 1052‐AP135 shown with Aruba Networks AP135 access point (not included) 2) Exploded view of the door, access point, and bracket Specifications: 




Adaptor door designed to mount the Aruba Networks AP135 802.11n wireless access point into existing Oberon Model 1052‐00 ceiling tile enclosures With adaptor door properly installed, the assembly is UL listed and designed to meet NEC300‐22 and 300‐23 for plenum installations Construction: Textured white powder‐coated steel, 14 ga. door Fully hinged locking door, keyed alike. Adaptor door is attached to enclosure with (3) nuts Model 38‐52‐AP135 Includes: 


Adaptor door Assembly mount bracket and nuts Installation instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1052‐AN BIM, CAD, and CSI Specifications Suspended Ceiling Enclosure The Model 1052‐AN wireless LAN access point enclosure is a locking, 2’ x 2’ ceiling tile enclosure designed specifically for the Aruba Networks access points with detachable antennas (AP‐60, AP‐70, AP‐120, AP‐124). This aesthetic, white powder coated steel enclosure has mounting features in the door for installation of the Aruba Networks antennas, simplifying installation & optimizing wireless coverage. No ceiling tile cuts are required for installation. Model 1052‐AN shown with Aruba Networks AP‐120 (not included) and (3) Aruba Networks AP‐ANT‐13B Antennas (not included) Specifications: 










Ceiling tile enclosure specifically designed for Aruba Networks APs with detachable antennas (AP‐60, AP‐70, AP‐120, AP‐124). AP‐70 requires Aruba Networks AP‐70‐MNT mounting bracket. AP‐120 and AP‐124 require the Aruba Networks AP‐120‐MNT mounting bracket. AP‐60 requires the Aruba Networks AP‐60‐MNT mounting bracket. (order from Aruba Networks) UL listed and designed to meet NEC300‐22 and 300‐23 for plenum installations OSHPD approved OPA # 1638 Mounting features on the door accommodate up to (3) Aruba Networks AP‐ANT‐13B antennas Construction: Textured white powder‐coated steel, 16 ga. backbox, 14 ga. door Fully hinged locking door, keyed alike Size: Flange is 2’ x 2’, AP Enclosure is 12.5" x 12.5 " x 4.5" deep Weight: 13lbs (not including access point or antenna) De‐rate upper operating temperature limit from +50°C to +40°C when AP in the enclosure Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1052‐AN Includes: 



Mounting screws and hardware (4) Suspension wires (2) ¾” Trade clamp connectors for power and data cable openings in the back‐box Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com PAGE 8
Model 1052‐AN‐ANT16 Suspended Ceiling Enclosure The Model 1052‐AN‐ANT16 wireless LAN access point enclosure is a locking, 2’ x 2’ ceiling tile enclosure designed specifically for the Aruba Networks access points with detachable antennas (AP‐60, AP‐70, AP‐120, AP‐124). This aesthetic, white powder coated steel enclosure has mounting features in the door for installation of the Aruba Networks AP‐ANT‐16 antenna, simplifying installation & optimizing wireless coverage. No ceiling tile cuts are required for installation. 1052‐AN‐ANT16 shown with Aruba Networks AP120 and AP‐ANT‐16 802.11n, 3 element, dual band antenna (not included) Specifications: 









Ceiling tile enclosure specifically designed for Aruba Networks access points with detachable antennas UL listed and designed to meet NEC300‐22 and 300‐23 for plenum installations OSHPD approved OPA # 1638 Mounting features on the door for the Aruba Networks AP‐ANT‐16 802.11n, 3 element, dual band antenna Construction: Textured white powder‐coated steel, 16 ga. backbox, 14 ga. door Fully hinged locking door, keyed alike Size: Flange is 2’ x 2’, AP Enclosure is 12.5" x 12.5 " x 4.5" deep Weight: 13lbs (not including access point or antenna) De‐rate upper operating temperature limit from +50°C to +40°C when AP in the enclosure Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1052‐AN‐ANT16 Includes: 



Mounting screws and hardware (4) Suspension wires (2) ¾” Trade conduit connectors for power and data cable openings in the back‐box Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1055‐AN Suspended Ceiling Enclosure The Model 1055‐AN wireless LAN access point enclosure is a locking, 2’ x 2’ ceiling tile enclosure designed specifically for the Aruba Networks access points with non‐detachable antennas (AP‐65, AP‐121, AP‐125). This aesthetic, white powder coated steel enclosure has an impact resistant, RF transparent dome that extends only 4.5” below the ceiling plane. No ceiling tile cuts are required for installation. Model 1055‐AN shown with Aruba Networks AP‐121 (not included) Specifications: 










Ceiling tile enclosure specifically designed for Aruba Networks access points with non‐detachable antennas (AP‐65, AP‐121, AP‐125). AP‐65 requires Aruba Networks AP‐65‐MNT mounting bracket. AP‐121 and AP‐125 require the Aruba Networks AP‐120‐MNT mounting bracket. (Order from Aruba Networks) Designed to meet NEC300‐22 and 300‐23 for plenum installations Dome is UL 94‐5VA Classified ABS Plastic OSHPD approved OPA # 1638 Construction: Textured white powder‐coated steel, 16 ga. backbox, impact resistant, RF transparent, ABS dome Fully hinged locking door, keyed alike Size: Flange is 2’ x 2’, access point enclosure is 12.5" x 12.5 " x 3.3" deep Weight: 13lbs (not including access point or antenna) De‐rate upper operating temperature limit from +50°C to +40°C when AP in the enclosure Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1052‐AN Includes: 



Access point mounting screws (4) Suspension wires (2) ¾” Trade size conduit connectors for power/data cable openings in the back‐box Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1059‐00 Suspended Ceiling Enclosure The Model 1059‐00 wireless LAN access point enclosure is a locking, 2’ x 2’ ceiling tile enclosure designed to accommodate access points with non‐detachable antennas from most manufacturers. This aesthetic, white powder coated steel enclosure has an impact resistant, RF transparent door, which protrudes only 4" below the ceiling plane. No ceiling tile cuts are required for installation. Model 1059‐00 shown with Aruba Networks AP121 (not included) Specifications: 










Ceiling tile enclosure designed for access points from most manufacturers RF transparent cover allows use of access point with non‐detachable or integrated antennas UL50 Listed and designed to meet NEC300‐22 and 300‐23 for plenum installations Dome is UL 94‐5VA Classified ABS Plastic OSHPD approved OPA # 1638 Enclosure is deep enough for any access point with an overall height of less than 5¾" Construction: Textured white powder‐coated steel, 16 ga. backbox, UL‐94V5A impact resistant textured white ABS door Fully hinged locking door, keyed alike Size: Flange is 2’ x 2’, AP Enclosure is 18" x 18" x 2.6" deep, ABS dome is 14" Sq. x 4" deep Weight: 17.5lbs (not including access point) Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1059‐00 Includes: 



Universal mounting plate, mounting screws and hardware (4) Suspension wires (2) ¾” Trade size conduit connectors for power/data cable openings in the back‐box Mounting Instructions Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com BIM, CAD, and CSI Specifications
Model 1026-00
NEMA Enclosure for Wireless APs – Hinged Cover
The Model 1026-00 is a compact NEMA enclosure designed to protect wireless LAN access points from most
vendors in challenging indoor/outdoor environments, such as stadiums. This rugged, polycarbonate enclosure
protects the access point from weather, dust, and impacts, and is transparent to wireless signals, so access
points with body integrated antennas or small detachable antennas may be protected. The enclosure has a
fully hinged cover, molded-in padlock hasps for locking, and interior mounting plate for attaching access
points. Convenient sizes are available. Enclosure and door are light gray. Smoked, clear doors are available.
Specifications:
•
•
•
•
•
•
•
•
•
Designed to NEMA 3R, 4, 4X, 12, and 13, and IEC529-IP66 specifications for indoor/ outdoor wet, dirty,
or corrosive environments. UV stabilized for exposure to direct sunlight.
UL listed to UL50 and UL508A. Back box and door are light gray UL94-5VA polycarbonate plastic
Transparent to wireless signals
Wall mounting holes are outside the sealed area, preventing ingress of moisture and dust
Cover is fully hinged. Cover can be latched and/or screwed tight and locked with padlock (not included)
Wireless access point max. operating temperature should be de-rated by 9 °C in the 1026-00
Std. Interior size: 12” x 10" x 6” deep. Other sizes available, please contact your Oberon representative
Weight: 4 lbs
Smoked clear polycarbonate cover is available upon request. Please specify as “-C” in model number
Model 1026-00 Includes:
• Interior universal mounting plate for wireless access points
• Wall mounting brackets
• Installation Instructions
Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867-2312 ● Fax (814) 867-2314 ● www.oberonwireless.com
BIM, CAD, and CSI Specifications
Model 1026-00
NEMA Enclosure for Wireless APs – Hinged Cover
Model 1026-00 Size Options:
Model Name
1026-1084
1026-1084-C
1026-12106
1026-12106-C
1026-14126
1026-14126-C
1026-16148
1026-16148-C
Interior Size
10” x 8” x 4”
10” x 8” x 4”
12” x 10” x 6”
12” x 10” x 6”
14” x 12” x 6”
14” x 12” x 6”
16” x 14” x 8”
16” x 14” x 8”
Cover
Opaque, light gray
Smoked, clear
Opaque, light gray
Smoked, clear
Opaque, light gray
Smoked, clear
Opaque, light gray
Smoked, clear
Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867-2312 ● Fax (814) 867-2314 ● www.oberonwireless.com
Model 1070 Ceiling Mounted Telecommunications Enclosures Oberon’s Model 1070 ceiling mounted telecommunications enclosure is a secure, convenient, and aesthetic telecommunications enclosure for rack mountable Ethernet switches, patch panels, wireless controllers and other networking and A/V components. The 1070 has mounting brackets for up to 2 standard (1U) rack mountable components, and back‐box openings to mount a patch panel and CCH fiber optic adaptor panel. The enclosure has a highly perforated door to allow airflow, for fan‐less operation. The 1070 is ideal for structured cabling and Fiber–to‐the‐Enclosure (FTTE) deployments. The enclosure can be used to shorten home‐runs to improve data rate and network capacity. Model 1070‐WH Model 1107‐BL Model 1070 Telecommunications Enclosure shown with 48‐port Ethernet Switch and Patch Panel (not included) Specifications: 








Telecommunications Enclosure (TE) designed for suspended ceiling environments Designed to accommodate up to 2 standard (1U) rack mountable components Includes back‐box openings for standard (1U) rack mountable patch panel and a CCH fiber optic adaptor panel (not included) UL Listed and is designed to satisfy National Electric Code (NEC) paragraphs 300‐22 and 300‐23 for installation in the air handling space Designed to fit into 2’ x 2’ ceiling tile grid‐work, accommodates networking equipment up to 2U deep and 14” in length Construction: Black powder coated aluminum Highly perforated door permits air‐flow without a fan. De‐rate networking equipment by 13º F (This is comparable to the temperature rise in an open rack). Weight: 7 lbs (not including networking equipment) Enclosure must be supported by the building ceiling structural system, not tile gridwork. Model 1070 Includes: 





(1) AC Junction box, receptacle, cover and screws (1) ½” Trade size conduit connector Grounding lug (4) Rack mounting screws Installation instructions Available in Black (1070‐BL) and White (1070‐WH) Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com Model 1070 (Cont.) Ceiling Mounted Telecommunications Enclosures An opening in the back box accommodates a standard 1U rack mountable patch panel (not included). This permits simplified cable management. An opening in the side wall accommodates a Closet Connector Housing (CCH) style fiber optic adaptor panel for Fiber To the Enclosure (FTTE) deployments (CCH not included). A highly perforated door permits passive air‐flow for fan‐less operation. The locking door uses a gas spring opener. Oberon, Inc. ● 1315 S. Allen Street ● State College, PA 16801 ● Phone (814) 867‐2312 ● Fax (814) 867‐2314 ● www.oberonwireless.com