High voltage fuse-links 36 Technical data 101 VV VV approved High voltage fuses POWER NEEDS CONTROL 35 High voltage fuse-links High voltage fuse-links High voltage high-breaking capacity VV fuse-links VV General information ETI HV fuse-links named VV THERMO are designed to protect devices in switch-gears and other equipment (distribution transformers, capacitors, motors) from thermal and dynamic effects of shortcircuits and overcurrents. Time-current characteristics correspond to standard IEC 60282-1, item 3.3.3. Back-up fuse. They are suitable for installation in: • indoor and outdoor switchgear • gas (SF6)-insulated enclosures • special service conditions (different from normal conditions, described in item 2.1. of standard IEC 60282-1) The most significant features of ETI high voltage fuses: • Low temperature rise bacause of low power dissipation •High breaking capacity 50 kA •Possibility of three different striker pin forces: 80 N and 120 N (with integrated temperature dependent limiter) and 50 N. •Reliable sealing system against humidity irruption •Low switching voltages •Upon a request, fuse links can be supplied into no-standard dimensions Overview of standard and no-standard dimmensions VV THERMO_ponudba standardnih in nestandardnih dimenzij.xls ETI HV THERMO 2A 4A 6A 10A 16A 20A 25A 32A 192 x Ø 53 50A Stran 1 63A 80A 100A 125A 160A 200A 250A 315A 192 x Ø 68 292 x Ø 53 7,2 kV 40A 192 x Ø 85 292 x Ø 68 292 x Ø 85 442 x Ø 68 192 x Ø 53 292 x Ø 53 12 kV 192 x Ø 68 292 x Ø 68 442 x Ø 53 292 x Ø 53 292 x Ø 68 367 x Ø 68 442 x Ø 68 292 x Ø 68 442 x Ø 53 24 kV 36 kV 442 x Ø 53 537 x Ø 53 537x Ø 68 537 x Ø 68 367 x Ø 85 442 x Ø 85 292 x Ø 85 442 x Ø 68 537 x Ø 53 442 x Ø 85 537 x Ø 85 292 x Ø 85 442 x Ø 53 292 x Ø 53 292 x Ø 85 442 x Ø 68 367 x Ø 53 17.5 kV 442 x Ø 85 442 x Ø 85 537 x Ø 85 537 x Ø 85 standard dimmension no- standard dimmension Pripravil V.Martincic 36 Stanje: Junij 2006 technical data on page 101 High voltage fuse-links VV Standards ETI VV (Medium Voltage) fuse-links comply with the following standards and specifications: •IEC 60282-1, Sixth edition 11/2005 “Current limiting fuses” •DIN 43625 “Hochspannungs-Sicherungen Nennspannung 3,6 bis 36kV” •“VDE 0670 T402, Wechselstromschaltgeraete fuer Spannungen ueber 1kV, Auswahl von strombegrenzenden Sicherungseinsaetzen fuer Transformatorstromkreise” / IEC 60787 “Application guide for the selection of high- voltage current limiting fuse-links for transformer circuits” •IEC 60644 “Specification for high-voltage fuse-links for motor circuit applications” •IEC 60549 “High-voltage fuses for external protection of power capacitors” Certificates, Test reports •CESI (Milan, Italy) certificate for 12kV, 17.5kV and 24kV •KERI (Chang Wong, S.Korea) certificate for 7.2kV and 24kV •ICMET (Craiova, Romania) test report for 36kV •Test reports for 25kV, 38.5kV, 40.5kV and 42kV versions Construction ETI high voltage fuses are designed to assure stable and reliable characteristics. The glazed porcelain tube (made in ETI own ceramic factory) is extremely high mechanical and thermal resistant. Galvanically protected contact caps made of electrolitic copper are nickel - or upon customer request silver plated. Caps are rolled by pressing into the groove of the tube. The tightness of this connection is assured by a special seal resistant to ageing and high temperatures. The design and method of production of the melting elements ensures precisely tolerances and stable time/current characteristics. Fuse elements are wounded on a ceramic carrier and electricaly welded on a special copper strips. The inside of the tube is filled with quarz sand with an exactly determined granulation and chemical structure. The sand guarantees good and reliable extinguishing of the electric arc. An important element in the fuse-link construction is also the striker system. Part of that system is temperature sensitive element, which reacts in cases of temperature increasing of the fuse-link due to various reasons. The reaction temperature is set to approximately 250°C on fuse tube surface. The system reacts in such a way that short time overloads do not cause the fuse to interroupt the circuit unnecessarily. Only when inadmissible values of surrounding temperatures are exceeded, the fuse open the switch via the striker pin. Because of these characteristics, ETI “thermal” striker pin is convenient for the protection of the fuse enclosure of SF6 switchgears which requires additional protection features against inadmissible temperatures of certain switchgear parts. Striker pin Type description, rated voltage 7,2 kV example: •VVC; 50N striker force (C mark). •VVT-D; Temperature limiter (VVT), 80N striker force (D mark). •VVT-E; Temperature limiter (VVT),120N striker force (E mark). technical data on page 101 37 High voltage fuse-links VV Ordering Code Numbers rated Dimension “e” rated current voltage according to DIN and IEC (mm) [A] Un [kV] 2A 4A 6A 10 A 16 A 20 A 25 A 32 A 192 40 A 50A 63 A 80 A 100 A 125A 160 A 6A 10 A 16 A 20 A 3/7.2 25 A 32 A 40 A 292 50 A 63 A 80A 100 A 125A 160 A 200 A 250 A 63 A 80A 100 A 125A 442 160 A 200 A 250 A 315 A VVC VVT-D VVT-E Striker type 50N Striker type 80N THERMO Striker type 120N THERMO 004225003 004225004 004225005 004225006 004225007 004225008 004225009 004225010 004225011 004225012 004225013 004225014 004225015 004225016 004225017 004225505 004225506 004225507 004225508 004225509 004225510 004225511 004225512 004225513 004225514 004225515 004225516 004225517 004225518 004225519 004225613 004225614 004225615 004225616 004225617 004225618 004225619 004225620 004226003 004226004 004226005 004226006 004226007 004226008 004226009 004226010 004226011 004226012 004226013 004226014 004226015 004226016 004226017 004226505 004226506 004226507 004226508 004226509 004226510 004226511 004226512 004226513 004226514 004226515 004226516 004226517 004226518 004226519 004226613 004226614 004226615 004226616 004226617 004226618 004226619 004226620 004227003 004227004 004227005 004227006 004227007 004227008 004227009 004227010 004227011 004227012 004227013 004227014 004227015 004227016 004227017 004227505 004227506 004227507 004227508 004227509 004227510 004227511 004227512 004227513 004227514 004227515 004227516 004227517 004227518 004227519 004227613 004227614 004227615 004227616 004227617 004227618 004227619 004227620 Tube diameter “d” (mm) weight [kg] 53 1.1 68 1.7 85 2.7 53 1.6 68 2.8 85 4.0 68 3.9 85 5.8 Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team. Note 2: Blue colored types according to IEC 60282-1 dimensions. 38 technical data on page 101 High voltage fuse-links VVC VVT-D VVT-E Striker type 50N Striker type 80N THERMO Striker type 120N THERMO 004235103 004235104 004235105 004235106 004235107 004235108 004235109 004235110 004235111 004235112 004235003 004235004 004235005 004235006 004235007 004235008 004235009 004235010 004235011 004235012 004235013 004235014 004235015 004235016 004235017 004235503 004235504 004235505 004235506 004235507 004235508 004235509 004235510 004235511 004235512 004235513 004235514 004235515 004235516 004235517 004235518 004235617 004235618 004235619 004236103 004236104 004236105 004236106 004236107 004236108 004236109 004236110 004236111 004236112 004236003 004236004 004236005 004236006 004236007 004236008 004236009 004236010 004236011 004236012 004236013 004236014 004236015 004236016 004236017 004236503 004236504 004236505 004236506 004236507 004236508 004236509 004236510 004236511 004236512 004236513 004236514 004236515 004236516 004236517 004236518 004236617 004236618 004236619 004237103 004237104 004237105 004237106 004237107 004237108 004237109 004237110 004237111 004237112 004237003 004237004 004237005 004237006 004237007 004237008 004237009 004237010 004237011 004237012 004237013 004237014 004237015 004237016 004237017 004237503 004237504 004237505 004237506 004237507 004237508 004237509 004237510 004237511 004237512 004237513 004237514 004237515 004237516 004237517 004237518 004237617 004237618 004237619 Tube diameter “d” (mm) weight [kg] VV Ordering Code Numbers rated Dimension “e” rated current voltage according to DIN and IEC (mm) [A] Un [kV] 2A 4A 6A 10 A 16 A 192 20 A 25 A 32 A 40 A 50A 2A 4A 6A 10 A 16 A 20 A 25 A 292 32 A 40 A 50 A 63 A 80 A 6/12 100 A 125 A 160 A 2A 4A 6A 10 A 16 A 20 A 25 A 32 A 442 40 A 50 A 63 A 80 A 100 A 125 A 160 A 200 A 160 A 537 200 A 250 A 53 1.1 68 1.7 53 1.6 68 2.8 85 4.0 53 2.3 68 3.9 85 5.8 85 7.0 Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team. Note 2: Blue colored types according to IEC 60282-1 dimensions. technical data on page 102 39 High voltage fuse-links VV Ordering Code Numbers rated Dimension “e” rated current voltage according to DIN and IEC (mm) [A] Un [kV] 2A 4A 6A 10 A 16 A 20 A 292 25 A 32 A 40 A 50A 63 A 80 A 2A 4A 6A 10 A 16 A 20 A 25 A 367 32 A 10/17,5 40 A 50 A 63 A 80A 100 A 125A 160 A 2A 4A 6A 10 A 16 A 20 A 25 A 442 32 A 40 A 50 A 63 A 80A 100 A 125A VVC VVT-D VVT-E Striker type 50N Striker type 80N THERMO Striker type 120N THERMO 004245103 004245104 004245105 004245106 004245107 004245108 004245109 004245110 004245111 004245112 004245113 004245114 004245003 004245004 004245005 004245006 004245007 004245008 004245009 004245010 004245011 004245012 004245013 004245014 004245015 004245016 004245017 004245503 004245504 004245505 004245506 004245507 004245508 004245509 004245510 004245511 004245512 004245513 004245514 004245515 004245516 004246103 004246104 004246105 004246106 004246107 004246108 004246109 004246110 004246111 004246112 004246113 004246114 004246003 004246004 004246005 004246006 004246007 004246008 004246009 004246010 004246011 004246012 004246013 004246014 004246015 004246016 004246017 004246503 004246504 004246505 004246506 004246507 004246508 004246509 004246510 004246511 004246512 004246513 004246514 004246515 004246516 004247103 004247104 004247105 004247106 004247107 004247108 004247109 004247110 004247111 004247112 004247113 004247114 004247003 004247004 004247005 004247006 004247007 004247008 004247009 004247010 004247011 004247012 004247013 004247014 004247015 004247016 004247017 004247503 004247504 004247505 004247506 004247507 004247508 004247509 004247510 004247511 004247512 004247513 004247514 004247515 004247516 Tube diameter “d” (mm) weight [kg] 53 1.6 68 2.8 85 4.0 53 1.9 68 3.1 85 4.6 53 2.3 68 3.9 85 5.8 Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team. Note 2: Blue colored types according to IEC 60282-1 dimensions. 40 technical data on page 103 High voltage fuse-links VVC VVT-D VVT-E Striker type 50N Striker type 80N THERMO Striker type 120N THERMO 004255103 004255104 004255105 004255106 004255107 004255108 004255109 004255110 004255111 004255112 004255113 004255003 004255004 004255005 004255006 004255007 004255008 004255009 004255010 004255011 004255012 004255013 004255014 004255015 004255016 004255503 004255504 004255505 004255506 004255507 004255508 004255509 004255510 004255511 004255512 004255513 004255514 004255515 004255516 004255517 004256103 004256104 004256105 004256106 004256107 004256108 004256109 004256110 004256111 004256112 004256113 004256003 004256004 004256005 004256006 004256007 004256008 004256009 004256010 004256011 004256012 004256013 004256014 004256015 004256016 004256503 004256504 004256505 004256506 004256507 004256508 004256509 004256510 004256511 004256512 004256513 004256514 004256515 004256516 004256517 004257103 004257104 004257105 004257106 004257107 004257108 004257109 004257110 004257111 004257112 004257113 004257003 004257004 004257005 004257006 004257007 004257008 004257009 004257010 004257011 004257012 004257013 004257014 004257015 004257016 004257503 004257504 004257505 004257506 004257507 004257508 004257509 004257510 004257511 004257512 004257513 004257514 004257515 004257516 004257517 Tube diameter “d” (mm) weight [kg] 53 1.6 68 2.8 85 4.0 53 2.3 68 3.9 85 5.8 53 2.8 68 4.7 85 7.0 VV Ordering Code Numbers rated Dimension “e” rated current voltage according to DIN and IEC (mm) [A] Un [kV] 2A 4A 6A 10 A 16 A 292 20 A 25 A 32 A 40 A 50A 63 A 2A 4A 6A 10 A 16 A 20 A 25 A 442 32 A 40 A 10/24 50 A 63 A 80A 100 A 125A 2A 4A 6A 10 A 16 A 20 A 25 A 537 32 A 40 A 50 A 63 A 80A 100 A 125 A 160 A Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team. Note 2: Blue colored types according to IEC 60282-1 dimensions. technical data on page 104 41 High voltage fuse-links VV Ordering Code Numbers rated Dimension “e” rated current voltage according to DIN and IEC (mm) [A] Un [kV] 2A 4A 442 6A 10 A 16 A 2A 4A 6A 20/36 10 A 16 A 20 A 537 25 A 32 A 40 A 50 A 63 A 80A ** VVC VVT-D VVT-E Striker type 50N Striker type 80N THERMO Striker type 120N THERMO 004265103 004265104 004265105 004265106 004265107 004265003 004265004 004265005 004265006 004265007 004265008 004265009 004265010 004265011 004265012 004265013 004265014 004266103 004266104 004266105 004266106 004266107 004266003 004266004 004266005 004266006 004266007 004266008 004266009 004266010 004266011 004266012 004266013 004266014 004267103 004267104 004267105 004267106 004267107 004267003 004267004 004267005 004267006 004267007 004267008 004267009 004267010 004267011 004267012 004267013 004267014 Tube diameter “d” (mm) weight [kg] 53 2.3 53 2.8 68 4.7 85 7.0 ** derating factor to take into consideration. Special parameters required. Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team. Note 2: Blue colored types according to IEC 60282-1 dimensions. 42 technical data on page 105 High voltage fuse-links Fuse bases for VV fuse-links 1-pole Indoor mounting VVP 12 1p-N VVP 24 1p-N VVP 36 1p-N Rated voltage [kV] 7,2 and 12 17,5 and 24 36 code No. 004239010 004259010 004269010 packaging [pcs] 1 1 1 VV type 1-pole Outdoor mounting type VVP 12 1p-Z VVP 24 1p-Z VVP 36 1p-Z Rated voltage [kV] 7,2 and 12 17,5 and 24 36 code No. 004239030 004259030 004269030 packaging [pcs] 1 1 1 Accessories Accessories for 3-pole Indoor fuse-bases type VVP 12 3p-N VVP 24 3p-N VVP 36 3p-N code No. 004239020 004259020 004269020 packaging [pcs] 1 1 1 Accessories for 3-pole Outdoor fuse-bases type VVP 12 3p-Z VVP 24 3p-Z VVP 36 3p-Z code No. 004239040 004259040 004269040 packaging [pcs] 1 1 1 Note: customer himself can assemble 3-pole fuse-base from 3pcs. of 1-pole fuse-base and 2pcs. of accessories. technical data on page 108, 109 43 VV Notes 44
© Copyright 2024