High voltage fuse

High voltage fuse-links
36
Technical data
101
VV
VV
approved
High voltage fuses
POWER NEEDS CONTROL
35
High voltage fuse-links
High voltage fuse-links
High voltage high-breaking capacity VV fuse-links
VV
General information
ETI HV fuse-links named VV THERMO are designed to protect devices in switch-gears and other equipment (distribution
transformers, capacitors, motors) from thermal and dynamic effects of shortcircuits and overcurrents. Time-current
characteristics correspond to standard IEC 60282-1, item 3.3.3. Back-up fuse.
They are suitable for installation in:
• indoor and outdoor switchgear
• gas (SF6)-insulated enclosures
• special service conditions (different from normal conditions, described in item 2.1. of standard IEC 60282-1)
The most significant features of ETI high voltage fuses:
• Low temperature rise bacause of low power dissipation
•High breaking capacity 50 kA
•Possibility of three different striker pin forces: 80 N and 120 N (with integrated temperature dependent limiter) and 50 N.
•Reliable sealing system against humidity irruption
•Low switching voltages
•Upon a request, fuse links can be supplied into no-standard dimensions
Overview of standard and no-standard dimmensions
VV THERMO_ponudba standardnih in nestandardnih dimenzij.xls
ETI HV THERMO
2A
4A
6A
10A
16A
20A
25A
32A
192 x Ø 53
50A
Stran 1
63A
80A 100A 125A 160A 200A 250A 315A
192 x Ø 68
292 x Ø 53
7,2 kV
40A
192 x Ø 85
292 x Ø 68
292 x Ø 85
442 x Ø 68
192 x Ø 53
292 x Ø 53
12 kV
192 x Ø 68
292 x Ø 68
442 x Ø 53
292 x Ø 53
292 x Ø 68
367 x Ø 68
442 x Ø 68
292 x Ø 68
442 x Ø 53
24 kV
36 kV
442 x Ø 53
537 x Ø 53
537x Ø 68
537 x Ø 68
367 x Ø 85
442 x Ø 85
292 x Ø 85
442 x Ø 68
537 x Ø 53
442 x Ø 85
537 x Ø 85
292 x Ø 85
442 x Ø 53
292 x Ø 53
292 x Ø 85
442 x Ø 68
367 x Ø 53
17.5 kV
442 x Ø 85
442 x Ø 85
537 x Ø 85
537 x Ø 85
standard dimmension
no- standard dimmension
Pripravil V.Martincic
36
Stanje: Junij 2006
technical data on page 101
High voltage fuse-links
VV
Standards
ETI VV (Medium Voltage) fuse-links comply with the following standards and specifications:
•IEC 60282-1, Sixth edition 11/2005 “Current limiting fuses”
•DIN 43625 “Hochspannungs-Sicherungen Nennspannung 3,6 bis 36kV”
•“VDE 0670 T402, Wechselstromschaltgeraete fuer Spannungen ueber 1kV, Auswahl von strombegrenzenden
Sicherungseinsaetzen fuer Transformatorstromkreise” / IEC 60787 “Application guide for the selection of high- voltage current limiting fuse-links for transformer circuits”
•IEC 60644 “Specification for high-voltage fuse-links for motor circuit applications”
•IEC 60549 “High-voltage fuses for external protection of power capacitors”
Certificates, Test reports
•CESI (Milan, Italy) certificate for 12kV, 17.5kV and 24kV
•KERI (Chang Wong, S.Korea) certificate for 7.2kV and 24kV
•ICMET (Craiova, Romania) test report for 36kV
•Test reports for 25kV, 38.5kV, 40.5kV and 42kV versions
Construction
ETI high voltage fuses are designed to assure stable and reliable characteristics. The glazed porcelain tube (made in ETI
own ceramic factory) is extremely high mechanical and thermal resistant.
Galvanically protected contact caps made of electrolitic copper are nickel - or upon customer request silver plated.
Caps are rolled by pressing into the groove of the tube. The tightness of this connection is assured by a special seal
resistant to ageing and high temperatures. The design and method of production of the melting elements ensures precisely tolerances and stable time/current
characteristics. Fuse elements are wounded on a ceramic carrier and electricaly welded on a special copper strips.
The inside of the tube is filled with quarz sand with an exactly determined granulation and chemical structure. The sand
guarantees good and reliable extinguishing of the electric arc.
An important element in the fuse-link construction is also the striker system. Part of that system is temperature sensitive
element, which reacts in cases of temperature increasing of the fuse-link due to various reasons. The reaction temperature
is set to approximately 250°C on fuse tube surface. The system reacts in such a way that short time overloads do not
cause the fuse to interroupt the circuit unnecessarily. Only when inadmissible values of surrounding temperatures
are exceeded, the fuse open the switch via the striker pin. Because of these characteristics, ETI “thermal” striker pin is
convenient for the protection of the fuse enclosure of SF6 switchgears which requires additional protection features
against inadmissible temperatures of certain switchgear parts.
Striker pin Type description, rated voltage 7,2 kV example:
•VVC; 50N striker force (C mark).
•VVT-D; Temperature limiter (VVT), 80N striker force (D mark).
•VVT-E; Temperature limiter (VVT),120N striker force (E mark).
technical
data on page 101
37
High voltage fuse-links
VV
Ordering Code Numbers
rated
Dimension “e” rated current
voltage
according to
DIN and IEC
(mm)
[A]
Un [kV]
2A
4A
6A
10 A
16 A
20 A
25 A
32 A
192
40 A
50A
63 A
80 A
100 A
125A
160 A
6A
10 A
16 A
20 A
3/7.2
25 A
32 A
40 A
292
50 A
63 A
80A
100 A
125A
160 A
200 A
250 A
63 A
80A
100 A
125A
442
160 A
200 A
250 A
315 A
VVC
VVT-D
VVT-E
Striker type
50N
Striker type
80N THERMO
Striker type
120N THERMO
004225003
004225004
004225005
004225006
004225007
004225008
004225009
004225010
004225011
004225012
004225013
004225014
004225015
004225016
004225017
004225505
004225506
004225507
004225508
004225509
004225510
004225511
004225512
004225513
004225514
004225515
004225516
004225517
004225518
004225519
004225613
004225614
004225615
004225616
004225617
004225618
004225619
004225620
004226003
004226004
004226005
004226006
004226007
004226008
004226009
004226010
004226011
004226012
004226013
004226014
004226015
004226016
004226017
004226505
004226506
004226507
004226508
004226509
004226510
004226511
004226512
004226513
004226514
004226515
004226516
004226517
004226518
004226519
004226613
004226614
004226615
004226616
004226617
004226618
004226619
004226620
004227003
004227004
004227005
004227006
004227007
004227008
004227009
004227010
004227011
004227012
004227013
004227014
004227015
004227016
004227017
004227505
004227506
004227507
004227508
004227509
004227510
004227511
004227512
004227513
004227514
004227515
004227516
004227517
004227518
004227519
004227613
004227614
004227615
004227616
004227617
004227618
004227619
004227620
Tube
diameter
“d” (mm)
weight
[kg]
53
1.1
68
1.7
85
2.7
53
1.6
68
2.8
85
4.0
68
3.9
85
5.8
Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team.
Note 2: Blue colored types according to IEC 60282-1 dimensions.
38
technical data on page 101
High voltage fuse-links
VVC
VVT-D
VVT-E
Striker type
50N
Striker type
80N THERMO
Striker type
120N THERMO
004235103
004235104
004235105
004235106
004235107
004235108
004235109
004235110
004235111
004235112
004235003
004235004
004235005
004235006
004235007
004235008
004235009
004235010
004235011
004235012
004235013
004235014
004235015
004235016
004235017
004235503
004235504
004235505
004235506
004235507
004235508
004235509
004235510
004235511
004235512
004235513
004235514
004235515
004235516
004235517
004235518
004235617
004235618
004235619
004236103
004236104
004236105
004236106
004236107
004236108
004236109
004236110
004236111
004236112
004236003
004236004
004236005
004236006
004236007
004236008
004236009
004236010
004236011
004236012
004236013
004236014
004236015
004236016
004236017
004236503
004236504
004236505
004236506
004236507
004236508
004236509
004236510
004236511
004236512
004236513
004236514
004236515
004236516
004236517
004236518
004236617
004236618
004236619
004237103
004237104
004237105
004237106
004237107
004237108
004237109
004237110
004237111
004237112
004237003
004237004
004237005
004237006
004237007
004237008
004237009
004237010
004237011
004237012
004237013
004237014
004237015
004237016
004237017
004237503
004237504
004237505
004237506
004237507
004237508
004237509
004237510
004237511
004237512
004237513
004237514
004237515
004237516
004237517
004237518
004237617
004237618
004237619
Tube
diameter
“d” (mm)
weight
[kg]
VV
Ordering Code Numbers
rated
Dimension “e” rated current
voltage
according to
DIN and IEC
(mm)
[A]
Un [kV]
2A
4A
6A
10 A
16 A
192
20 A
25 A
32 A
40 A
50A
2A
4A
6A
10 A
16 A
20 A
25 A
292
32 A
40 A
50 A
63 A
80 A
6/12
100 A
125 A
160 A
2A
4A
6A
10 A
16 A
20 A
25 A
32 A
442
40 A
50 A
63 A
80 A
100 A
125 A
160 A
200 A
160 A
537
200 A
250 A
53
1.1
68
1.7
53
1.6
68
2.8
85
4.0
53
2.3
68
3.9
85
5.8
85
7.0
Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team.
Note 2: Blue colored types according to IEC 60282-1 dimensions.
technical data on page 102
39
High voltage fuse-links
VV
Ordering Code Numbers
rated
Dimension “e” rated current
voltage
according to
DIN and IEC
(mm)
[A]
Un [kV]
2A
4A
6A
10 A
16 A
20 A
292
25 A
32 A
40 A
50A
63 A
80 A
2A
4A
6A
10 A
16 A
20 A
25 A
367
32 A
10/17,5
40 A
50 A
63 A
80A
100 A
125A
160 A
2A
4A
6A
10 A
16 A
20 A
25 A
442
32 A
40 A
50 A
63 A
80A
100 A
125A
VVC
VVT-D
VVT-E
Striker type
50N
Striker type
80N THERMO
Striker type
120N THERMO
004245103
004245104
004245105
004245106
004245107
004245108
004245109
004245110
004245111
004245112
004245113
004245114
004245003
004245004
004245005
004245006
004245007
004245008
004245009
004245010
004245011
004245012
004245013
004245014
004245015
004245016
004245017
004245503
004245504
004245505
004245506
004245507
004245508
004245509
004245510
004245511
004245512
004245513
004245514
004245515
004245516
004246103
004246104
004246105
004246106
004246107
004246108
004246109
004246110
004246111
004246112
004246113
004246114
004246003
004246004
004246005
004246006
004246007
004246008
004246009
004246010
004246011
004246012
004246013
004246014
004246015
004246016
004246017
004246503
004246504
004246505
004246506
004246507
004246508
004246509
004246510
004246511
004246512
004246513
004246514
004246515
004246516
004247103
004247104
004247105
004247106
004247107
004247108
004247109
004247110
004247111
004247112
004247113
004247114
004247003
004247004
004247005
004247006
004247007
004247008
004247009
004247010
004247011
004247012
004247013
004247014
004247015
004247016
004247017
004247503
004247504
004247505
004247506
004247507
004247508
004247509
004247510
004247511
004247512
004247513
004247514
004247515
004247516
Tube
diameter
“d” (mm)
weight
[kg]
53
1.6
68
2.8
85
4.0
53
1.9
68
3.1
85
4.6
53
2.3
68
3.9
85
5.8
Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team.
Note 2: Blue colored types according to IEC 60282-1 dimensions.
40
technical data on page 103
High voltage fuse-links
VVC
VVT-D
VVT-E
Striker type
50N
Striker type
80N THERMO
Striker type
120N THERMO
004255103
004255104
004255105
004255106
004255107
004255108
004255109
004255110
004255111
004255112
004255113
004255003
004255004
004255005
004255006
004255007
004255008
004255009
004255010
004255011
004255012
004255013
004255014
004255015
004255016
004255503
004255504
004255505
004255506
004255507
004255508
004255509
004255510
004255511
004255512
004255513
004255514
004255515
004255516
004255517
004256103
004256104
004256105
004256106
004256107
004256108
004256109
004256110
004256111
004256112
004256113
004256003
004256004
004256005
004256006
004256007
004256008
004256009
004256010
004256011
004256012
004256013
004256014
004256015
004256016
004256503
004256504
004256505
004256506
004256507
004256508
004256509
004256510
004256511
004256512
004256513
004256514
004256515
004256516
004256517
004257103
004257104
004257105
004257106
004257107
004257108
004257109
004257110
004257111
004257112
004257113
004257003
004257004
004257005
004257006
004257007
004257008
004257009
004257010
004257011
004257012
004257013
004257014
004257015
004257016
004257503
004257504
004257505
004257506
004257507
004257508
004257509
004257510
004257511
004257512
004257513
004257514
004257515
004257516
004257517
Tube
diameter
“d” (mm)
weight
[kg]
53
1.6
68
2.8
85
4.0
53
2.3
68
3.9
85
5.8
53
2.8
68
4.7
85
7.0
VV
Ordering Code Numbers
rated
Dimension “e” rated current
voltage
according to
DIN and IEC
(mm)
[A]
Un [kV]
2A
4A
6A
10 A
16 A
292
20 A
25 A
32 A
40 A
50A
63 A
2A
4A
6A
10 A
16 A
20 A
25 A
442
32 A
40 A
10/24
50 A
63 A
80A
100 A
125A
2A
4A
6A
10 A
16 A
20 A
25 A
537
32 A
40 A
50 A
63 A
80A
100 A
125 A
160 A
Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team.
Note 2: Blue colored types according to IEC 60282-1 dimensions.
technical
data on page 104
41
High voltage fuse-links
VV
Ordering Code Numbers
rated
Dimension “e” rated current
voltage
according to
DIN and IEC
(mm)
[A]
Un [kV]
2A
4A
442
6A
10 A
16 A
2A
4A
6A
20/36
10 A
16 A
20 A
537
25 A
32 A
40 A
50 A
63 A
80A **
VVC
VVT-D
VVT-E
Striker type
50N
Striker type
80N THERMO
Striker type
120N THERMO
004265103
004265104
004265105
004265106
004265107
004265003
004265004
004265005
004265006
004265007
004265008
004265009
004265010
004265011
004265012
004265013
004265014
004266103
004266104
004266105
004266106
004266107
004266003
004266004
004266005
004266006
004266007
004266008
004266009
004266010
004266011
004266012
004266013
004266014
004267103
004267104
004267105
004267106
004267107
004267003
004267004
004267005
004267006
004267007
004267008
004267009
004267010
004267011
004267012
004267013
004267014
Tube
diameter
“d” (mm)
weight
[kg]
53
2.3
53
2.8
68
4.7
85
7.0
** derating factor to take into consideration. Special parameters required.
Note 1: Other ratings and dimensions can be supplied by customer request. For particular applications, please contact ETI technical team.
Note 2: Blue colored types according to IEC 60282-1 dimensions.
42
technical data on page 105
High voltage fuse-links
Fuse bases for VV fuse-links
1-pole Indoor mounting
VVP 12 1p-N
VVP 24 1p-N
VVP 36 1p-N
Rated voltage
[kV]
7,2 and 12
17,5 and 24
36
code No.
004239010
004259010
004269010
packaging
[pcs]
1
1
1
VV
type
1-pole Outdoor mounting
type
VVP 12 1p-Z
VVP 24 1p-Z
VVP 36 1p-Z
Rated voltage
[kV]
7,2 and 12
17,5 and 24
36
code No.
004239030
004259030
004269030
packaging
[pcs]
1
1
1
Accessories
Accessories for 3-pole Indoor fuse-bases
type
VVP 12 3p-N
VVP 24 3p-N
VVP 36 3p-N
code No.
004239020
004259020
004269020
packaging
[pcs]
1
1
1
Accessories for 3-pole Outdoor fuse-bases
type
VVP 12 3p-Z
VVP 24 3p-Z
VVP 36 3p-Z
code No.
004239040
004259040
004269040
packaging
[pcs]
1
1
1
Note: customer himself can assemble 3-pole fuse-base from 3pcs. of 1-pole fuse-base and 2pcs. of accessories.
technical data on page 108, 109
43
VV
Notes
44