Managing Asbestos in Buildings: A Guide for Owners and Managers A Revision to the United States Environmental Protection Agency’s 1985 document Guidance for Controlling Asbestos-Containing Materials in Buildings (EPA 560/5-85-024) Known as the Purple Book The Environmental Information Association, Inc. ASBESTOS • LEAD • MOLD • INDOOR AIR QUALITY Managing Asbestos in Buildings: A Guide for Owners and Managers 1 Managing Asbestos in Buildings: A Guide for Owners and Managers A Revision to the United States Environmental Protection Agency’s 1985 document Guidance for Controlling Asbestos-Containing Materials in Buildings (EPA 560/5-85-024) known as the Purple Book First Edition, March, 2015 A product of volunteer effort by: The Environmental Information Association, Inc. 6935 Wisconsin Avenue, Suite 306 Chevy Chase, MD 20815-6112 [email protected] A NOTE FROM THE EIA TO THOSE THAT MANAGE SCHOOL PROPERTIES (K-12): This document is a general treatment of asbestos issues to assist those that own or manage buildings that can contain asbestos-containing materials. Much of the information included here would also be germane to these issues in school properties. But do be advised that this document does not specifically enumerate the responsibilities for the management of asbestos issues on school-related properties. The Environmental Protection Agency (EPA) has long established asbestos control regulations and guidance for schools. The EPA has a very helpful web page to guide those that are responsible for school properties and their regulatory responsibilities regarding asbestos management issues. Please take the time to open this web page and look for the section called “School Buildings.” http://www2.epa.gov/asbestos DISCLAIMER The authors of this document have created this publication to provide the owners and managers of properties that are known to have, or may contain, asbestos-containing materials with general guidance concerning the management of these materials. It was not written to serve as a technical document for asbestos control specialists. Reprinted material is quoted with permission and sources are indicated. Reasonable efforts have been made to publish reliable data and information but the authors cannot assume responsibility for the validity of all materials or typographical errors. Where interpretations of federal regulations have been made those interpretations reflect a consensus of opinions by the authors and asbestos control industry experts who peer reviewed this document and are not intended to represent a legal interpretation of the regulations. No attempt has been made incorporate regulations found at the State and Local level. If legal advice or other expert assistance is required, in relation to specific issues raised in this document, the services of a competent professional should be sought. Efforts were made to assure that all photographs used in this document were clear of copyright violations. If any photograph used in this document is in violation of any copyright we will remove the item or properly cite its reference in the next document revision. INFORMATION REGARDING LINKS TO WEB PAGES IN THIS DOCUMENT We made a significant effort to assure that all web page links in this document were functioning when we completed our editing process. It is likely that web links can change over time, especially those for federal and State/Local agencies. If a link does not appear to be working, copy the link from the text and paste it into your browser. This may be a matter of software as much as it could be a broken web page link. The reader should adjust security settings in software to assure web pages are not blocked because of web page content or a “pop-up blocker” setting. It is also possible that a web page could be unavailable because of periodic server maintenance. If the reader does ascertain that a web link is not functioning, please notify the EIA office. We will keep a list of any non-functioning web page links and will issue addendums periodically as a service to our readers. Managing Asbestos in Buildings: A Guide for Owners and Managers 3 Copyright Copyright © 2015 by the Environmental Information Association (EIA). All rights reserved. No part of this publication may be used or reproduced in any manner whatsoever without written permission from the EIA. This publication is provided to a Licensee as an electronic download publication, and is licensed only to the Licensee whose name appears in the footer on each page. The document can be printed one time, and one time only, by the Licensee purchasing a license. If there is no footer present on the pages of this document, or if there are multiple documents with the same footer and Licensee name/number, then a copyright violation exists, and EIA would appreciate a report of any violations to our offices immediately. Ownership. You (Licensee) have no ownership or other rights in this EIA Document. This is not a sale of this EIA document. All right, title and interest in this EIA Document (in both electronic file and hard copy) belongs to EIA. You may not remove, change, modify or obscure the copyright notice or other notices contained in this EIA Document. Limited License. EIA grants you a limited, non-transferable license as follows: The right to download an electronic file of this EIA Document for temporary storage on one computer for purposes of viewing, and/or printing one copy of this EIA document for individual use. Neither the electronic file nor the single hard copy print may be reproduced in any way. In addition, the electronic file may not be distributed elsewhere over computer networks or otherwise. That is, the electronic file cannot be e-mailed, downloaded to disk, copied to another hard drive, or otherwise shared. The single hard copy print may only be distributed to other employees for their internal use within your organization; it may not be copied. This EIA Document may not otherwise be sold or resold, rented, leased, lent or sub-licensed, except as specifically authorized in writing by EIA. The Licensee will be responsible for all access control and security measures necessary to ensure that the Licensee’s IP addresses are not used to access this EIA Document other than by authorized Users. Verification. EIA has the right to verify compliance with this License Agreement, at its expense, and at any time during the course of normal business hours. To do so, EIA will engage an independent consultant, subject to a confidentiality agreement, to review your use this EIA Document. You agree to permit access to your information and computer systems for this purpose. Verification will take place upon no less than 15 days notice, during normal business hours and in a manner that does not interfere unreasonably with your operations. If verification reveals unlicensed use of this EIA Document, you must reimburse EIA for the costs incurred in verification and reimburse EIA for any unlicensed uses. By invoking this procedure, EIA does not waive any of its rights to enforce this Agreement or to protect its intellectual property by any other means permitted by law. Passwords. You must immediately notify EIA of any known or suspected unauthorized use(s) of your password, or any known or suspected breach of security, including the loss, theft or unauthorized disclosure of your password or any unauthorized access to or use of this EIA Document. You are solely responsible for maintaining the confidentiality of your password and for ensuring the authorized access and use of this EIA Document. Definitions. For purposes of this License, an Authorized Site is a localized site (one geographical location) that is under a single administration at a single location. For a Licensee with locations in more than one city, each city is considered to be a different site. For a Licensee with multiple locations in the same city, each location is considered to be a different site. (If you are seeking online access for multiple sites, please contact EIA at 888-343-4342 or [email protected]). Authorized User means only the employees, faculty, staff, and students officially affiliated with the Licensee at the Authorized Site, and persons with legal access to the library’s collections and facilities at the Authorized Site, using an IP address within the range identified in the subscription. Authorized Users may be persons remote from the Licensee’s physical location whose access is administered from the Authorized Site, but not persons at remote sites or campuses with separate administrations. For example, an employee of the Licensee may be considered to be an Authorized User when accessing the Subscriber’s network from home or while traveling to another city; however, employees of a branch campus or facility in another city are not considered to be Authorized Users. Licensee is the person or entity which has purchased a license from the EIA and agreed to the terms of this limited license. Termination. This Agreement is effective until terminated. You may terminate this Agreement at any time by destroying all copies (hard, digital or in any media) of this EIA Document. Governing Law, Venue, Jurisdiction. This Agreement shall be interpreted and construed in accordance with the laws of the State of Maryland. Licensee agrees to submit to jurisdiction and venue in the state and federal courts of Maryland for any dispute which may arise under this Agreement. You also agree to waive any claim of immunity you may possess. Disclaimer of Warranty. All express or implied conditions, representations and warranties, including any implied warranty of merchantability, fitness for a particular purpose or non-infringement are disclaimed, except to the extent that these disclaimers are held to be legally invalid. Limitation of Liability. To the extent not prohibited by law, in no event will EIA be liable for any loss, damage, lost data or for special, indirect, consequential or punitive damages, however caused regardless of the theory of liability, arising out of or related to the use or downloading of this EIA Document. In no event will EIA’s liability exceed the amount paid by you under this License Agreement. Environmental Information Association 6935 Wisconsin Avenue, Suite 306 Chevy Chase, MD 20815 301-961-4999 888-343-4342 [email protected] www.eia-usa.org 4 Managing Asbestos in Buildings: A Guide for Owners and Managers Acknowledgements Many individuals contributed their volunteer time and efforts for this document revision. Without their generous efforts we would not have been able to complete this project. The contributors to this document span a wide collection of talents from those that serve as physicians, medical researchers, architects, engineers, industrial hygienists, consultants, laboratory scientists, contractors, and training specialists. Our goal was to gather a wide variety of experiences and perspectives to be able to provide technically accurate and up-to-date information from the consensus of industry professionals. The EIA thanks each for their contribution to the successful completion of this important project. EIA Steering Panel In alphabetical order Kevin Cannan, AAC Contracting, Inc., Rochester, New York Bill Cavness, The Asbestos Institute, Phoenix, Arizona Ronald F. Dodson, Ph.D., F.C.C.P., F.A.H.A., Dodson Environmental Consulting, Inc., Tyler, Texas William M. Ewing, CIH, Compass Environmental, Inc., Kennesaw, Georgia Steve M. Hays, PE, CIH, FACEC, FAIHA, Gobbell Hays Partners, Inc., Nashville, Tennessee David W. Hogue, The Environmental Institute (a division of Cardno), Marietta, Georgia David Kahane, MPH, CIH, Forensic Analytical, Hayward, California J. Brent Kynoch, Environmental Information Association, Inc, Chevy Chase, Maryland Thomas G. Laubenthal, The Environmental Institute (a division of Cardno), Marietta, Georgia James R. Millette, Ph.D., D-IBFES, MVA Scientific Consultants, Duluth, Georgia Andrew F. Oberta, MPH, CIH, The Environmental Consultancy, Austin, Texas Michael W. Schrum, P.E., Terracon, Charlotte, North Carolina James S. Webber, Ph.D., Webber Environmental Health Consulting, LLC, Pleasantville, NY. Section Authors Summary of Guidance & Chapter 1 Thomas G. Laubenthal, The Environmental Institute (a division of Cardno), Marietta, Georgia Chapter 1 (Health Effects) Ronald F. Dodson, Ph.D., F.C.C.P., F.A.H.A., Dodson Environmental Consulting, Inc., Tyler, Texas Jeffrey L. Levin, MD, MSPH, FACOEM, The University of Texas Health Science Center at Tyler, Tyler, Texas Paul P. Rountree, MD, FACOEM, The University of Texas Health Science Center at Tyler, Tyler, Texas Chapter 2 David W. Hogue, The Environmental Institute (a division of Cardno), Marietta, Georgia Chapter 3 Andrew F. Oberta, MPH, CIH, The Environmental Consultancy, Austin, Texas Joy N. Finch, CET, Greenville Technical College, Greenville, South Carolina Chapter 4 J. Brent Kynoch, Environmental Information Association, Chevy Chase, Maryland Michael W. Schrum, P.E., Terracon, Charlotte, North Carolina Chapter 5 Peter DeLucia, AAC Contracting, Inc., Rochester, New York Kevin Cannan, AAC Contracting, Inc., Rochester, New York Chapter 5 (abatement final clearance issues) James R. Millette, Ph.D., D-IBFES, MVA Scientific Consultants, Duluth, Georgia Thomas G. Laubenthal, The Environmental Institute (a division of Cardno), Marietta, Georgia External Peer Review In alphabetical order Ronald Arena, Chem Scope Inc., North Haven CT Thomas J. Broido, Cardno, Williston, VT Dana Brown, GEBCO Associates, Hurst, Texas Chris Davis, Belfor Environmental, Tucker, Georgia John Dietrichs, SafTech Consultants, Inc., Dunwoody, Georgia Joy N. Finch, CET, Greenville Technical College, Greenville, South Carolina Sean Fitzgerald, PG, Scientific Analytical Institute, Inc. Greensboro, North Carolina Michael R. Gray, Alternative Actions, Inc., Hixson, TN Marianne Hillmann, CSP, CHMM, Hillmann Consulting, LLC, Westfield, Pennsylvania Jeff Mlekush, QuanTEM Laboratories, LLC, Oklahoma City, Oklahoma Roger G. Morse, AIA, Morse Associates, Inc., Troy, NY Additional Acknowledgements Photographs Many thanks to the following for their assistance in providing photographs in this document: Anthony Rich of Livonia Michigan was extremely helpful in proving many pictures to help illustrate ACMs in current and historical use. Many more excellent pictures of many aspects of asbestos history and the products produced can be found at the link below. We suggest that those new to the asbestos issue spend some time here for an overview of the vast array of ACMs found in buildings: https://www.flickr.com/photos/asbestos_pix/ Ben Greene of Grayling Industries, Inc. for all pictures of glovebags used in this document. Darryl Watson, CIH, CSP, JD, Cardno, Marietta, GA for his assistance in providing assistance with text in the Disclaimer Additionally, the pictures used in the Health Effects section of Chapter 1 and those found in Chapters 3 and 5 were principally provided by the section authors. Managing Asbestos in Buildings: A Guide for Owners and Managers 5 Preface Thank you for purchasing the Environmental Information Association, Inc.’s (EIA) document “Managing Asbestos in Buildings: A Guide for Owners and Managers.” We sincerely hope you will find this document informative and helpful for your management of asbestos issues in the properties you own or manage. This project was based upon a realized need within the leadership of the EIA and the asbestos– control industry to update the topics originally addressed in a 1985 United States Environmental Protection Agency (EPA) document entitled “Guidance for Controlling Asbestos-Containing Materials in Buildings” (EPA 560/5-85-024). The industry has referred to this original document as the “Purple Book” due to the color of its cover. When this document was published by the EPA, it was the principal source of information on basic asbestos issues faced by industry. Since the original publication of the Purple Book, the regulatory landscape has changed dramatically and our knowledge of asbestos control has improved significantly. For those that own and/or manage properties, there really has been a need for an updated Purple Book-type document that contained current information and guidance on asbestos control issues. This is our effort to provide that information to building owners and managers in a similar format to that of the original document. This project was not undertaken to merely update the original information found in the EPA’s Purple Book. The information is this document contains significant revisions to that of the original EPA publication. This project was undertaken entirely by volunteers from EIA’s leadership and membership with no outside funding. On July 20, 2009, the EIA convened a steering committee meeting of senior asbestos-control industry leaders to review the need for this project. The consensus was that industry would benefit by our undertaking this process. From that point, all of the sections were written by volunteers that generously gave of their time and expertise in authorship and multiple reviews. The EIA also arranged and conducted a detailed peer review of the written materials. Peer-reviewers were chosen from applications sent by EIA members to best represent a cross section of professionals within the asbestos-control industry. They also gave generously of their time and expertise as volunteers. This document was written for the general guidance of the owners and managers of properties that do or may contain asbestos-containing materials. It was not written to serve as a technical document for asbestos control specialists. The document was specifically written to address federal regulatory requirements, not the wide varieties of regulations found at the State and Local level. It is mentioned many times in this document that the reader has the responsibility to know regulatory variations at the State or Local level with the recognition that the most stringent guidelines are those applicable to given circumstances. The reader will find many helpful hyperlinks to web pages to assist in their information gathering. This document was written and peer-reviewed by asbestos control industry experts. As such, what the reader will find is that within this guidance we have agreed to a consensus of opinion. We did not try to incorporate every variation of opinion that can exist in how asbestos is controlled or perceptions of regulatory compliance. Because each chapter was written by volunteers, the reader will find some variation in writing style and subsection numbering. Despite our best efforts to provide technically accurate information in this document, we realize that errors may be found. We plan to have subsequent updates in the future to address technical errors or changes in federal asbestos regulations. This project was not funded by the EPA or any other source. Further, the EPA had no part in its revision or peer-review. We make no claim of EPA endorsement of this document. It was produced by the EIA and its members and leadership to service the building owners and managers in the United States. In this we hope we can assist the building owner/manager community to make informed decisions that will keep them in compliance with regulations, manage asbestos effectively and protect their workers and occupants from asbestos exposures. We hope you find this document of value! 6 Managing Asbestos in Buildings: A Guide for Owners and Managers Message from the Editor-in-Chief This document would not have been possible without the foresight and leadership of dedicated senior members of EIA leadership. It started out with a conversation between friends at an EIA conference and with much effort and time passed we have produced what we hope will be a standard in the asbestos control industry for many years. We will be updating this document periodically and will improve our explanations and graphics as revisions are made; we are dedicated to that effort. My personal thanks to the following people that were of great help to me over the long haul in producing this first edition of Managing Asbestos in Buildings: A Guide for Owners and Managers: My co-workers at The Environmental Institute; Dave Hogue, Rachel McCain and Lisa Bucher. Their patience with my long hours of writing and then performing multiple rounds of editing was instrumental to my being able to complete my tasks to bring this document together. Without their support, this project would not have been completed. Andrew Oberta, MPH, CIH; many thanks for Andy’s willingness to pick up his phone and help me hash out many details on regulatory compliance matters. Andy’s service to the asbestos-control industry is surpassed by few. Tom Broido is a coworker with Cardno who manages an office in Vermont. Tom provided me much appreciated patient guidance and mature wisdom when frustrations in sorting out materials, and divergent opinions, became difficult. Joy Finch, CET, is a colleague in the environmental training industry based in Greenville, South Carolina. There were many that provided helpful editing assistance via peer review activities, but few have the talent Joy exhibited. Her assistance made for a better document. There are many others I could name, but the list would become quite long; thanks to all that helped along the way. I do offer many thanks to the long hours and time donated by those that served on the Steering Committee, section writers and peer reviewers. Without all of their effort and vast expertise the technical excellence we planned for would not have been possible. I thank the EIA leadership and its members for allowing me the honor to have served in the role of management of this project to produce what we hope will be long lasting asbestos guidance to the building owners and managers of the United States and our neighbors. The honor has been to serve… Thomas G. Laubenthal Editor-in Chief Managing Asbestos in Buildings: A Guide for Owners and Managers 7 Contents Summary of Guidance This section provides a simple overview of the topics that will be covered in this document. Chapter 1 Background on Asbestos in Buildings 1.1 Asbestos in Buildings.....................................................14 1.1.1 What is Asbestos?.........................................................14 1.1.2 The Regulatory Definition of Asbestos..........................15 1.2 Could I Have Asbestos In My Building?.........................16 1.2.1 ACM Found in Buildings................................................16 1.2.2 EPA Types of Asbestos Containing Materials (ACM)....18 1.2.3 Does Having ACM in My Building Present a Problem?..20 1.2.4 Levels of Airborne Asbestos in Buildings.......................20 1.3 Diseases Associated with Exposure to Asbestos..........20 1.3.1 Size of Respirable Dusts................................................21 1.3.2 Routes of Entry into the Body-Respiratory and Digestive System....................................................21 1.3.3 Defense Mechanisms of the Body against Inhaled Dust..22 1.3.3.1 General Structure of the Respiratory System................22 1.3.3.2 Mucociliary Escalator (mucus, cilia and clearance/translocation).................................................23 1.3.3.3 Impact of Smoking on Risk of Disease Including Asbestos-induced Diseases..........................................23 1.3.3.4 Body Defense Cells (Inflammation)...............................23 1.3.4 Asbestos Exposure and Induction of Disease...............24 1.3.4.1 Asbestos Exposure and Disease...................................24 1.3.4.2 Period from Exposure to Development of Disease (Latency)........................................................................24 1.3.4.3 Diseases Associated with Asbestos Exposure..............24 1.3.5 Importance of Early Diagnosis and Clinical Annual Evaluations............................................25 1.3.5.1 Medical Surveillance Requirements..............................25 1.3.5.2 Good Clinical Practice....................................................26 1.4 Federal Regulations Regarding Asbestos in Buildings...26 1.4.1 United States Environmental Protection Agency (EPA)..28 1.4.1.1 EPA Asbestos NESHAP; 40 CFR Part 61, Subpart M..28 1.4.1.2 EPA AHERA “Asbestos in Schools”; 40 CFR Part 763..29 1.4.1.3 EPA Worker Protection Rule (40 CFR Part 763, Subpart G).......................................30 1.4.2 Occupational Safety and Health Administration (OSHA)...........................................................................30 1.4.2.1 Asbestos General Industry Standard; 29 CFR 1910.1001.........................................................31 1.4.2.2 Asbestos Construction Standard; 29 CFR 1926.1101.........................................................31 1.5 State/Local Asbestos Regulatory Programs..................32 References...................................................................................33 Appendix 1: Representative List Of Materials Likely To Contain Asbestos............................................34 8 Managing Asbestos in Buildings: A Guide for Owners and Managers Chapter 2 Determining If Asbestos-Containing Material (ACM) Is Present In Buildings 2.1 Planning the Survey.......................................................36 2.1.1 What is the Purpose of the Asbestos Survey?..............36 2.1.2 Different Types of Asbestos Surveys.............................37 2.1.3 Who Should Conduct the Asbestos Survey?.................37 2.2 Conducting the Survey...................................................38 2.2.1 General Survey Elements..............................................38 2.2.1.1 Pre-Survey Planning......................................................38 2.2.1.2 Building Document Review............................................39 2.2.2 Specific Survey Elements..............................................39 2.2.2.1 AHERA Surveys (as described in 40 CFR Part 763.86)..39 2.2.2.2 OSHA Surveys...............................................................41 2.2.2.3 NESHAP “Thorough Inspection” Requirements............41 2.2.2.4 Pre-O&M Surveys..........................................................42 2.2.2.5 Abatement Design Surveys...........................................42 2.2.2.6 Limited Area and Limited Material Surveys...................43 2.2.2.7 ASTM Survey Standards...............................................43 2.2.3 Special Survey Considerations......................................44 2.2.3.1 Drywall/Taping/Joint Compound....................................44 2.2.3.2Vermiculite......................................................................45 2.2.3.3Soils................................................................................46 2.3 Bulk Sample Analysis.....................................................46 2.3.1 Polarized Light Microscopy (PLM).................................46 2.3.1.1 Point Counting................................................................47 2.3.2 Transmission Electron Microscopy (TEM).....................48 2.3.3 Laboratory Accreditation................................................48 2.4 Survey Report................................................................49 Chapter 3 Assessment of Asbestos Containing Materials 3.1 3.2 3.3 3.3.1 3.3.1.1 3.3.1.2 3.3.2 3.3.3 3.3.3.1 3.3.3.2 3.4 Why assess asbestos-containing materials?................50 What aspects of asbestos-containing materials are assessed?................................................50 How and when are asbestos-containing materials assessed?......................................................51 What is an algorithm and how is it used?......................51 An early algorithm..........................................................51 Two current algorithms...................................................51 What is the AHERA protocol?........................................51 What are the ASTM assessment protocols..................54 What is the E2356 qualitative protocol?........................54 What is the E2356 quantitative protocol?......................54 What conclusions can we draw about the assessment protocols?.......................................................................56 Appendix A....................................................................................57 Appendix B...................................................................................58 Contents Chapter 4 Establishing an Operations and Maintenance (O&M) Program Chapter 5 Abatement Methods: Characteristics and Recommended Work Practices 4.1 4.2 4.2.1 4.2.2 4.2.3 4.3 4.3.1 4.3.2 4.3.3 4.3.3.1 4.3.3.2 4.3.3.3 4.3.4 4.3.4.1 4.3.4.2 4.3.5 4.3.6 4.3.6.1 4.3.6.3 4.3.6.4 4.3.6.5 4.3.6.6 4.3.7 4.3.8 4.3.9 4.4 5.1 5.1.1 5.1.2 5.2 5.2.1 5.2.2 5.2.2.1 5.2.2.2 5.2.2.3 5.3 5.3.1 5.3.2 5.4 5.4.1 5.4.2 5.5 5.5.1 5.5.1.1 Purpose of an O&M Program........................................59 Setting up the O&M Program.........................................59 Surveying the Building for Asbestos-Containing Materials (ACM).............................................................59 Appoint an Asbestos Program Manager (APM)............59 Development of an O&M Program................................60 Elements of the O&M Program......................................60 Written O&M Program....................................................60 Work Permit System......................................................60 Training...........................................................................60 Types of Training for O&M Activities..............................62 Who Should Conduct Training.......................................63 Where to Find Training...................................................63 Occupant and Contractor Notification............................63 Information for Occupants (Tenants and other occupants)......................................63 Additional Information for Occupants (contractors and workers)..............................................63 Periodic Inspection.........................................................63 Asbestos O&M Work Practices......................................64 When to Apply Special O&M Work Practices................64 Work Practices when Disturbance Is Possible or Intended..................................................65 Work Practices when Disturbance Is Unlikely...............65 Work Practices Prohibited by OSHA..............................66 Air Monitoring for O&M Activities...................................66 Procedures for Asbestos Fiber Release Episodes........67 Procedures for Cleaning................................................67 Recordkeeping...............................................................68 Addressing Asbestos during Demolition and Renovation Projects................................................68 What is Asbestos Abatement and when is Abatement Appropriate?............................70 What is Asbestos Abatement?.......................................70 When is Abatement Appropriate?..................................71 Planning the Asbestos Abatement Project.....................71 Credentials of the Project Designer...............................71 What is an Asbestos Project Design?............................71 Project Scope.................................................................72 Schedule for Abatement- Timing and Phasing..............72 Specifications.................................................................73 Who Should do the Abatement Work?..........................73 In-house or Contracted..................................................74 Training, Licensing and Certification..............................74 Selecting a Contractor...................................................74 Contractor Selection Criteria..........................................74 Pre-bid Walk-through.....................................................75 Abatement Methods and Control Options.....................75 Abatement Methods.......................................................77 Abatement Methods for Sprayed- or Troweled-on Surfacing Material..........................................................78 5.5.1.2 Abatement Methods for Pipe and Boiler Insulation.......79 5.5.1.3 Abatement Methods for Other Types of ACM................80 5.5.1.4 Abatement Methods for Vermiculite...............................80 5.5.2 Other Control Options....................................................81 5.5.2.1 Enclosure.......................................................................81 5.5.2.2 Encapsulation.................................................................81 5.5.3 Project Notification Requirements.................................82 5.5.4Disposal..........................................................................82 5.5.5 OSHA Required Exposure Assessments & Respiratory Protection................................................83 5.6 Managing the Work........................................................84 5.6.1 Responsibilities for the Owner/Manager and Employers of Other Employees Adjacent to the Abatement Work........84 5.6.2 The Role of the Consultant............................................84 5.6.3 Project Monitoring & Visual Inspections........................85 5.7 Final Clearance Testing and Air Sample Analysis.........86 5.7.1 Air Sample Analysis Options..........................................87 5.7.1.1 Other Available TEM Methods.......................................88 5.7.2 AHERA Method for Final Clearance Testing..................88 5.7.2.1 Requirements.................................................................88 5.7.2.2 Other Requirements.......................................................89 5.7.3 Final Clearance Air Sampling for Non-AHERA Abatement Projects..................................90 5.7.4 Sample Analysis of Final Clearance Air Samples..........90 5.7.5 Release Criterion...........................................................90 5.7.6 Quality Assurance..........................................................91 5.8 Contractor Release and Recordkeeping.......................92 5.9 Replacement Materials Considerations.........................92 Appendix A Comparison tables of abatement options....................................94 Managing Asbestos in Buildings: A Guide for Owners and Managers 9
© Copyright 2024