10-6. HOW TO CHECK THE PARTS PLA-RP35BA.UK PLA-RP50BA.UK PLA-RP100BA.UK PLA-RP125BA.UK PLA-RP35BA1.UK PLA-RP50BA1.UK PLA-RP35BA#2.UK PLA-RP50BA#2.UK PLA-RP100BA#2.UK PLA-RP125BA#2.UK PLA-RP71BA2.UK PLA-RP100BA2.UK PLA-RP60BA.UK PLA-RP71BA.UK PLA-RP140BA.UK PLA-RP60BA1.UK PLA-RP71BA1.UK PLA-RP60BA#2.UK PLA-RP71BA#2.UK PLA-RP140BA#2.UK PLA-RP125BA2.UK PLA-RP140BA2.UK Orange Drain float switch (FS) Orange 28 10-6-1. Thermistor < Thermistor for lower temperature > <Thermistor Characteristic graph> Thermistor for lower temperature 50 Room temperature thermistor (TH1) Pipe temperature thermistor/liquid (TH2) Condenser/evaporator temperature thermistor (TH5) Thermistor R0=15kù ± 3% Fixed number of B=3480 ± 2% Rt=15exp { 3480( 0æ 10æ 20æ 25æ 30æ 40æ 1 273+t 40 30 1 )} 273 20 15kù 9.6kù 6.3kù 5.4kù 4.3kù 3.0kù 10 0 -20 -10 0 10 20 30 40 50 Temperature ( ) 10-6-2. DC Fan motor (FAN MOTOR/INDOOR CONTROLLER BOARD) Check method of DC fan motor (fan motor / indoor controller circuit board) Notes · High voltage is applied to the connector (CNMF) for the fan motor. Pay attention to the service. · Do not pull out the connector (CNMF) for the motor with the power supply on. (It causes trouble of the indoor controller circuit board and fan motor.) Self check Symptom : The indoor fan cannot turn around. Indoor controller board fuse check Is the resistance between the terminals of drain pump normal? Is the fuse normal? Yes Replace the fan motor. Replace the indoor controller board. No Wiring contact check Replace the drain pump. Is there contact failure? Yes Wiring recovery No Power supply check (Remove the connector (CNMF)) Measure the voltage in the indoor controller circuit board. TEST POINT : VDC (between 1 (+) and 4 (-) of the fan connector): VDC DC 310~340 V TEST POINT : VCC (between 5 (+) and 4 (-) of the fan connector): VCC DC 15 V Is the voltage normal? Yes Replace the fan motor. OK No Check the operation of fan. Replace indoor controller board NG Replace indoor controller board. OK Check the operation END NG Replace the fan motor. 29 END 10-7.TEST POINT DIAGRAM Indoor controller board PLA-RP35/50/60/71/100/125/140BA.UK PLA-RP35/50/60/71BA1.UK PLA-RP30/50/60/71/100/125/140BA#2.UK PLA-RP71/100/125/140BA2.UK LED3 Transmission (Indoor/outdoor) CN90 Connect to the wireless remote controller board (CNB) CN3G Connect to the auto grille controller board (CN3G) 13V pulse output CNV Vane motor output (MV) 12V pulse output CN4Y i-see sensor SW1 Model selection CN6Y i-see sensor motor output 12V DC pulse output SW2 Capacity setting LED2 Power supply (R.B) Jumper wire J41,J42 Pair No. setting for wireless remote controller CN4F Drain float switch (FS) CN2L Connector (LOSSNAY) CN44 Pipe temperature thermistor ï-î : Liquid (TH2) í-ì : SWE Emergency operation CN41 Connector (HA terminal-A) CN32 Connector (Remote switch) CN20 Room temperature thermistor (TH1) CN22 Connect to the terminal block (TB5) (Remote controller connecting wire) (10.4~14.6V DC) LED1 Power supply (I.B) CN3C Transmission (Indoor/outdoor) (0~24V DC) VCC : Voltage between pins of C955 15VDC (Same as ë(+)–ì(-) of CNMF) CNMF Fan motor ï-ì: DC 310~340V ë-ì: DC15V CN01 Connect to the Terminal Block (TB4) (Indoor/outdoor connecting line) Between í and ë 220-240V AC CNP Drain-pump output (DP) (220-240V AC) CNAC Connect to the auto grille controller board (CN3A) (220-240V AC) FUSE 6.3A /250V 30
© Copyright 2024