3D Breast MultiWaveTM Ultrasound Imaging Aixplorer® MultiWave Technology brings you unrivaled diagnostic confidence with impeccable 3D breast imaging quality and, never seen before, 3D ShearWaveTM Elastography. Impeccable 3D Image Quality The Aixplorer® now offers 3D Breast ultrasound, the latest technology for breast visualization and lesion classification. Aixplorer’s impeccable 3D image quality gives you the ability to view both traditional and non-traditional scanning planes for an improved diagnostic process. Acquired 3D volumetric data together with 3D display features deliver new information of breast pathology. With the Aixplorer 3D Breast Application, suspicious tissue can be visualized in any plane of the 3D volume, particularly in the coronal or C-plane for a high resolution morphological assessment. In addition, compression pattern and retraction/star pattern can be leveraged together with the coronal plane to give supplementary information about lesion morphology. 3D ShearWave Elastography (SWE) An incredible innovation, a phenomenal clinical tool, never seen before: Quantitative Ultrasound Elastography in 3D! Only the Aixplorer advances your diagnostic confidence to this level with its patented 3D ShearWave Elastography. This non-invasive, unique technology offers you a 3D color-coded elasticity map of tissue stiffness. In a single 3D acquisition, Aixplorer produces a reproducible, quantifiable (kPa) 3D elastography volume, as well as, a high-resolution 3D B-mode volume. The 3D elastography map provides unprecedented clinical information of the elasticity distribution inside and around a breast lesion. 3D ShearWave Elastography maximizes your diagnostic potential and is a must-have tool for lesion characterization, lesion follow-up under treatment, and surgical planning. Key Features and Benefits The SuperLinear VolumetricTM 16-5 Transducer The SLV16-5 broadband transducer is designed specifically for breast and small parts to help you acquire the clearest images and the most accurate data possible in every exam. This transducer has been ergonomically studied and validated by physicians and sonographers to fit perfectly in your hand. It is optimized to produce high quality 2D and 3D B-mode imaging as well as precise ShearWave Elastography imaging. Acquisition workflow is optimized to provide you with fast and accurate access to 3D information, with a high resolution B-mode volume acquired in less than 3 seconds and a combined B-mode/ SWE 3D volume in less than 10 seconds. 3D Display and Study Management The advanced 3D on-cart review package enables visualization and review of acquired 3D volumes, including B-mode and B-mode + SWE. Aixplorer’s 3D user interface allows you to quickly navigate to traditional orthogonal planes, or perform a virtual re-scan through the volume in any plane. MultiPlanar and MultiSlice display options provide the ability to layout imaging planes for rapid reading and interpretation. Advanced navigation tools (translation and rotation) allow you to analyze any area of interest from a new perspective. Accelerate your workflow by appending optimal views after the study and sending only the most informative images to the workstation for rapid interpretation. Advanced Measurements A new collection of 3D measurement tools is available in MultiSlice and MultiPlanar display to perform accurate 3D volume lesion evaluations. The 3D package also includes all the tools available for 2D imaging including 2D distance, trace, ellipse, Q-Box TM and Q-Box TM Ratio. Navigation and measurement workflows are optimized to provide fast access to measurement results and volume evaluations. Case studies A B MultiPlanar display of 2 mm diameter benign cyst. MultiSlice display (coronal planes) of complex multicystic lesion including ducts. C D MultiPlanar display of BI-RADS® 3 solid lesion. E F MultiSlice display (coronal planes) of a BI-RADS® 5 lesion (ShearWave Elastography opacity set to 0%). www.supersonicimagine.com MultiSlice display (coronal planes), of image E, BI-RADS® 5 lesion (ShearWave Elastography opacity set to 50%). FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01755 - 01 / 106V1 - BI3D100901B41 3D ShearWave TM Elastography map of a benign cyst displayed in MultiPlanar with 2/3-1/3 view mode of a benign cyst. Contrast MultiWaveTM Ultrasound Imaging Aixplorer® MultiWave Technology enables impeccable image quality and real-time ShearWaveTM Elastography that is now combined with contrast imaging to give you improved clinical solutions and diagnostic confidence. Impeccable Contrast Image Quality Key Features and Benefits Aixplorer® provides not only, impeccable B-mode image quality but also, advanced and comprehensive Contrast Enhanced Ultrasound (CEUS) solutions for the detection, characterization and monitoring of solid tumors throughout the body. The SuperCurvedTM 6-1 MHz transducer ShearWave Elastography and Contrast Imaging For the first time ever, breakthrough ShearWave Elastography technology in addition to CEUS enables the comparison of blood flow in the microcirculation with the mechanical and structural properties of tissue, giving more diagnostic confidence for every patient. The SC 6-1 broadband transducer supports CEUS applications in the abdomen, including focal liver lesion detection and characterization, plus renal applications. This lightweight transducer has been ergonomically studied and validated by physicians and sonographers to fit perfectly into your hand in a relaxed position. Ease of Use Display Modes • Side by Side Display Enables Real-Time Low MI B-mode and contrast to be displayed together, providing guidance before and during a contrast injection. The B-mode tissue image can be used to ensure a lesion is in the scan plane while the contrast image displays, simultaneously, the contrast phases within the lesion and surrounding tissue. Early arterial enhancement of a small Hepatocellular carcinoma. One touch button on the control panel enables you to switch to and from conventional B-mode imaging to contrast imaging without losing your preferred settings. Long Loop Capture • Guarantees up to five minutes of contrast acquisition time in both prospective and retrospective captures. • Enables a complete capture of all vascular phases during a liver contrast injection. • Exportable in DICOM or High Quality H264 lossless video format. • Display 1 Up - Increases the contrast image to full screen improving the frame rate for better visualization of micro-bubbles traversing the vasculature. • Flash Imaging - Rapidly destroys micro-bubbles in the scan plane to facilitate the observation of dynamic micro-bubble replenishment. • Contrast Timer - Tracks the time from the start of the contrast injection to document the different vascular phases of an injection. • MVI: Micro-Vascular Imaging - Follows the passage of micro bubbles over time to improve the visualization of the vascular architecture of lesions and other flow patterns. • POI: Real-time duplicated Point of Interest - Real-time duplicated Point of Interest in side-by-side mode assists in the correlation of differences in contrast signal with anatomical structures provided by the low MI B-mode image. Case studies A B Late vascular phase of a large focal nodular hyperplasia (FNA) where both the central scar and centripetal filling were not visible in contrast or B-mode. The same central scar (image A) is clearly visible and easily obtained on the ShearWaveTM Elastography map. C D Late phase of same liver lesion (image C) demonstrating excellent enhancement after a 3 minute interval, illustrating minimal contrast agent destruction. E F Post radiofrequency ablation of Hepatocellular carcinoma (HCC) in liver. www.supersonicimagine.com Image of a recurrence after radiofrequency ablation of a metastasis. The hyperenhanced region on the contrast image delineates the extent of recurrence. FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01768 - 01 / 118V1 - XI2D100901B41 Arterial phase of a liver lesion exhibiting localized blood pooling, a differentiating characteristic of hemangioma. Gynaecology MultiWaveTM Ultrasound Imaging MultiWave Technology brings you impeccable gynaecological imaging quality and real-time ShearWaveTM Elastography for a comprehensive solution for your patients. Impeccable GYN Image Quality Impeccable B-mode image quality in axial and lateral dimension for all your clinical GYN needs. Aixplorer’s GYN application is optimized to achieve maximum resolution to obtain fine morphological structure detail of the ovaries, adnexae and endometrium, including difficult cases such as a fibroid uterus. ShearWave Elastography for GYN Imaging For the first time ever, breakthrough ShearWave Elastography technology enables the quantitative (kPa) assessment of lesion elasticity, without manual compression. ShearWave Elastography could improve diagnostic confidence by determining new growth of fibroids or confirming cystic, complex or solid ovarian masses. In addition, ShearWave Elastography could be useful in post-fibroid embolization follow-up assessment or for the visualization of any stiffer versus softer areas. As ShearWave Elastography is reproducible and operator independent it may assist in the detection of suspicious morphology, guide biopsies and monitor lesions post therapy. Key Features and Benefits The SuperEndocavity TM 12-3 Transducer The SE 12-3 broadband transducer is designed specifically for all your gynaecological clinical needs to help you acquire the most accurate data possible for every exam and for every body habitus. This lightweight transducer has been ergonomically studied and validated by physicians and sonographers to fit perfectly in your hand in a relaxed position. The transducer is designed with a small end-fire tip, for maximum patient comfort and a convenient handgrip for easy maneuvering. Directional Color Power Doppler Enables extreme sensitivity in detection and direction of low flow perfusion in ovarian cysts and fibroids. Pulsed Wave Doppler Extremely sensitive for the maximum visualization of low velocity blood flow in ovaries as well as high velocity blood flow in the uterus. SuperCompound TM Guarantees excellent B-mode image quality while in Color or ShearWave Elastography imaging. Case studies A B Ovarian follicular cyst with dCPI (directional Color Power Imaging). Coronal view of a normal uterus. C D Digitally zoomed view of the cervix demonstrating nabothian cysts and the internal cervical os. E F B-mode image of a sagittal view on a normal uterus with excellent detail of the endometrial canal during the secretory phase. www.supersonicimagine.com The ShearWaveTM Elastography map demonstrates stiffer septae of this complex ovarian cyst. FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01764 - 01 / 114V1 - XI2D100901B41 Impeccable image quality of the adnexa including an ovarian follicular cyst and the iliac vein and artery. Prostate MultiWaveTM Ultrasound Imaging MultiWave Technology brings you impeccable imaging quality and real-time ShearWaveTM Elastography to deliver unparalleled prostate diagnostic confidence. Impeccable Prostate Image Quality Due to its location, the prostate gland poses real challenges to the medical imaging field. The Aixplorer® addresses these challenges by providing outstanding lateral, axial and contrast resolution in order to maximize the visualization of fine structures and improve conspicuity of complex areas. ShearWave Elastography for Prostate Imaging Breakthrough ShearWave Elastography technology enables the quantitative assessment in kilopascals of prostate elasticity, without manual compression. This operator independent, reproducible tool is useful in assessing focal changes in prostate stiffness to help locate and characterize prostate inhomogeneities and to monitor post therapy. In addition, biopsy can be performed with a simultaneous visualization of both the ShearWave Elastography image and the B-mode image, increasing precision and certainty. Key Features and Benefits The SuperEndocavity TM 12-3 Transducer The SE 12-3 broadband transducer is designed specifically for all your prostate clinical needs to give you the most accurate data possible for every exam. This lightweight transducer has been ergonomically studied and validated by physicians and sonographers to fit perfectly in your hand in a relaxed position. The transducer is designed with a small end-fire tip for maximum patient comfort and a convenient handgrip for easy maneuvering. Directional Color Power Doppler Enables extremely high sensitivity in evaluating flow in prostatic lesions or prostatitis. SuperCompound TM Guarantees excellent B-mode image quality while in Color or ShearWave Elastography imaging. Case studies A B Impeccable image quality: full view of large prostate (6 cm). Prostate lobes with coarse and microcalcifications. C D Superb contrast resolution of well defined suspicious hypoechoic mass in left lobe. E F Hyperechoic area appears stiffer (100 kPa) compared to surrounding tissue. Excellent B-mode is preserved with SuperCompound in SWE imaging. www.supersonicimagine.com Q-Box™ Moy 161,12 kPa Min 101,23 kPa Max 180,00 kPa Ecart type 3,1 Q-Box™ Moy 91,28 kPa Min 38,29 kPa Max 171,04 kPa Ecart type 5,2 ShearWaveTM Elastography map shows prostate calcification as a stiffer region (140 kPa) than surrounding tissue. FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01760 - 01 / 110V1 - PI2D100901B41 Excellent spatial and contrast resolution of a heterogeneous prostate with SuperCompoundTM and SuperResTM. Customer Care SonicCareTM SuperSonic Imagine offers you SonicCareTM, a Quality Customer Support Program designed with your needs in mind to give you complete satisfaction with your innovative Aixplorer® MultiWave TM Ultrasound System. A complete solution for all your maintenance needs SonicCare Protection Plans can be tailored to answer your needs to develop sustained maximum performance, higher productivity and increased efficiency, so you can spend more time on what’s important to you. Our team of highly trained clinical and technical specialists have years of expertise in delivering quality customer support through field services, technical call centers, training centers and logistics networks. Performance Protection Plans Gold and Silver Annual Maintenance Contracts deliver value-focused, flexible solutions that are tailored to your requirements. The plans can be customized to combine both key elements and important options to suit your needs and preferences. Options may include additional transducer protection, priority software install and system options discount. We will work with you to select the best options available to fulfill your department and facility requirements. Technical Support Exemplary technical expertise is only a phone call away; online remote diagnostics and service support are available to deliver fast answers and solutions to ensure optimum system availability. Our support technicians can provide a wide range of services including spare parts, corrective maintenance, safety checks, quality assurance, preventative maintenance, technical phone support, remote service, replacement and damage protection of transducers and software updates that enhance the efficiency of the system. Remote Service Aixplorer’s Remote Service effortlessly offers you a proactive diagnostic evaluation for your ultrasound system to reduce downtime. Our service team will devise and implement a comprehensive solution in a timely manner. In addition, with your authorization and full control, access can be available to new technology that permits a mirror image of your main monitor and touch screen to be sent from your facility to our dedicated service technicians. This capability gives you real-time assistance for your service needs and your imaging challenges. SonicCareTM Performance Protection Plans* Description Spare Parts Furnishes spare parts for defective components (includes shipping and handling) Corrective Maintenance Includes labor and travel required to correct system malfunction or failure Safety Checks Ensures system is in compliance with all local and national guidelines and regulations Quality Assurance Verifies that the system is within the published equipment specifications Preventative Maintenance Guarantees system reliability and continuous availability Technical Phone Support Phone support provided by the customer care team to assist with technical issues Remote Service Allows remote diagnosis of technical issues and reduces downtime Replacement Transducers Transducer Damage Protection Provides for an immediate replacement transducer in the event of failure Supplies an immediate replacement transducer in the event of accidental damage Software Updates Software updates that enhance system efficiency Gold Silver � � � � � � � � � � � � � � � � � � � In addition to our maintenance programs, support services are available on demand. * This table offers a guideline as to some of the elements included in SonicCareTM www.supersonicimagine.com FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01776 - 01 / 126V1 - XI2D100901B41 Key elements Element Annual Contract (Invoiced & Paid in Month One) SuperTransducersTM MultiWaveTM Ultrasound Imaging Designed for optimal sensitivity and operator comfort, the Aixplorer® SuperTransducer family gives you the power to acquire extraordinary images on every patient. Comprehensive solutions to all imaging challenges Aixplorer’s ultra wideband transducers with their unique core acoustic technology and advanced ergonomic design enable exceptional detail of tissue in every exam in both B-mode and ShearWaveTM Elastography imaging. The SuperTranducer family has a unique capability to fire a Mach cone pulse sequence which in turn provokes a ‘push’ in ShearWave Elastography mode, without inducing a cool-down phase. Incredible technology for optimal sensitivity and operator comfort The SuperTransducer family (SL15-4, SLV16-5, SC6-1 and SE12-3), is based on highperformance transducer technology. This technology overcomes the well-known trade-off between sensitivity and bandwidth frequency, rendering extraordinary clinical performance in deep penetration, high resolution and contrast. The transducer acoustic stack uses the latest generation of piezocomposite materials engineered with advanced efficiency piezoceramics and innovative polymer technology. These innovative features exhibit very high coupling coefficient, low acoustic impedance and high damping. The transducer architecture embeds multilevel, matching and backing layers for perfect agreement with the propagation medium and maximization of both transducer bandwidth and acoustic output power. This amazing increase in performance, as compared to conventional transducer technology, uniquely leverages the ability to increase the frequency range of transducers for various clinical application presets (eg: the SL15-4 is able to cover superficial breast to deep breast in a single transducer). The ergonomic design of the SuperTransducer family provides lightweight transducers and cables. These transducers have been ergonomically studied and validated by physicians and sonographers to fit perfectly in your hand in a relaxed position in order to reduce the risk of work related injury. Key Features and Benefits SuperLinearTM 15-4 Number of Elements: 256 Bandwith: 4-15 MHz SuperLinearTM Volumetric 16-5 Number of Elements: 192 Bandwith: 5-16 MHz SuperCurvedTM 6-1 Number of Elements: 192 Bandwith: 1-6 MHz SuperEndocavityTM 12-3 Number of Elements: 192 Bandwith: 3-12 MHz SuperTransducerTM Family SuperCurvedTM 6-1 Application Presets Breast Breast, Superficial Breast Deep Breast Thyroid Superficial Thyroid Intestine Scrotum Superficial MSK MSK General, Research Thyroid Abdominal Genitourinary Musculoskeletal General Number of Elements: 256 Bandwith: 4-15 MHz Acoustic Footprint: 51 mm Biopsy Guide: Free-angle disposable with a reusable bracket Features: • Ultra lightweight • Easy to hold Application Presets Thyroid Abdominal Renal Pelvic Genitourinary General Thyroid Abdomen, Liver Difficult Abdomen Renal Pelvis Prostate General, Research Number of Elements: 192 Bandwith: 1-6 MHz Field of View: 61 Degree Acoustic Footprint: 64 mm Biopsy Guide: Multi-angle, re-usable bracket with disposable needle guides Features: • Ultra lightweight • Easy to hold • 60 mm radius of curvature • Ergonomically validated to provide excellent intercostal access SuperLinearTM Volumetric 16-5 SuperEndocavityTM 12-3 Application Presets Application Presets Breast General Breast General, Research Pelvic Genitourinary General Gyn Prostate General www.supersonicimagine.com Number of Elements: 192 Bandwith: 5-16 MHz Acoustic Footprint: 38 x 43 mm Features: • Sweep angles: 10, 20 and 30 degrees • Volumetric breast aquisition Number of Elements: 192 Bandwith: 3-12 MHz Field of View: 138 Degree Acoustic Footprint: 28 mm Biopsy Guide: Mono-angle disposable or reusable Features: • Small radius of Curvature • Slim design • Ergonomic handle • Endfire FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01780 - 01 / 130V1 - RI2D100901B41 SuperLinearTM 15-4 Musculoskeletal (MSK) MultiWaveTM Ultrasound Imaging Aixplorer® MultiWave Technology enables impeccable image quality and real-time ShearWaveTM Elastography to provide new diagnostic capabilities for all your MSK needs. Impeccable MSK Image Quality Unparalleled image quality of muscles, tendons, ligaments, joints and soft tissue, from throughout the body, is easily achieved and interpreted using innovative technologies such as SuperCompoundTM to help answer your MSK imaging challenges. ShearWave Elastography for MSK Imaging Breakthrough real-time ShearWave Elastography enables the quantitative assessment, in kilopascals, of changes in muscle and tendon tissue stiffness. This reproducible, operator independent, innovation offers incredible millimetric resolution that assists in the characterization of abnormal tissue and small local injuries, as well as the monitoring of changes after patient re-education or surgery. Key Features and Benefits The SuperLinearTM 15-4 transducer The SL15-4 broadband, high-performance transducer renders unprecedented high quality images that bring new information and visualization, never seen before in MSK imaging. With a large effective bandwidth both spatial resolution and penetration are optimized as well as powerful harmonic imaging. SuperCompoundTM Guarantees excellent B-mode image quality with incredible definition, continuity and contrast resolution, even while in Color Mode or ShearWave Elastography. Directional Color Power Doppler Enables extremely high sensitivity in evaluating flow of tissue micro-vascularizations. Case studies A B Fracture of the second phalanx with clearly visualized bone fragment using SuperCompound TM and SuperRes TM imaging. Soleus calf muscle relaxed and contracted: showing clear increase in stiffness of the muscle during contraction , from 14 kPa to 74 kPa. C D Retrocalcanear bursitis, Haglund’s disease of Achilles’ tendon. E F Palmar view of the median nerve: demonstrating excellent detail of the hyperechoic flexor tendons with the surrounding thin hypoechoic synovial sheath. www.supersonicimagine.com ShearWaveTM Elastography map of calcification in painful shoulder. FRANCE +33 (0)4 88 19 68 55 I UK +44 (0)845 643 4516 I USA +1 (425) 686 6380 I GERMANY +49 89 36036 844 SSID01772 - 01 / 122V1 - SI2D100901B41 Inflammation of the Achilles’ tendon with intratendinous microvascularization.
© Copyright 2024