WWW.GEZELMANPE.COM/PV/0328S.GS.WILLOWGARDENS_WINDERMERE_FL.PDF NOTES FOR PCM, US-NATION-WIDE, GENERIC, PV, STRUCTURAL INSTALLATION THIS SEALED PLAN CONFORMS TO: ASCE 7-10; INTERNATIONAL BUILDING CODE (IBC) 2010 - PLUS EARLIER VERSIONS; STATE BUILDING CODES BASED UPON IBC - FLORIDA 2010 FBC IN PARTICULAR. THIS PLAN IS: • INTENDED FOR THE STRUCTURAL ATTACHMENT OF ANY AND ALL APPROVED PV MODULES OF STANDARD LENGTH & WIDTH DIMENSIONS AND PROPORTIONS. • INTENDED FOR USE WITH ROOF COVERINGS OF ALL TYPES AND ON ALL ROOF SLOPES FROM FLAT THRU 12-IN-12 AT ROOF HEIGHTS OF 60-FT OR LESS WITHIN US. • SHALL ONLY BE USED FOR PV INSTALLATIONS UTILIZING PCM RAILS & SPECIFIED HARDWARE. THIS PLAN SHALL ONLY BE USED FOR MOUNTING PV MODULES: • THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS AN EV (ELECTRONIC VERSION) OF THIS PLAN AT WWW.GEZELMANPE.COM/PV/0203P.PCM10_US.PDF . HYPERLINKS ARE EMBEDDED IN EV WHICH PROVIDE EASY ACCESS TO SUPPLEMENTAL OEM, GOVERNMENTAL, AND OTHER INFORMATION SOURCES OF VALUE. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AT A MAGNIFICATION OF HIS CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN THE SPECIFICATIONS HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. MOUNTING LIMITATIONS: 1. ROOF PRESSURE ZONE 3 (PZ-3) SHALL NOT BE USED WITHIN MIAMI-DADE. OUTSIDE MIAMI-DADE, PZ3 MAY BE USED WITH AN EOR (ENGINEER OF RECORD) SPECIAL REQUEST, SEALED, LETTER WHICH SHALL PROVIDE DETAILS FOR SITE-SPECIFIC ADAPATION OF THIS PLAN. PZ1 & PZ2 MAY BE USED ANYWHERE IAW (IN ACCORDANCE WITH) PCM RAIL SPACING SPECIFIED IN FIGURE 02 THIS PLAN. 2. PV MODULES SHALL BE MOUNTED PARALLEL WITH ROOF (AND WITHIN A FEW INCHES) OR TILTED UP AT NOT GREATER THAN (NGT) 15-DEGREES FROM THE HORIZONTAL . 3. THOSE DESIRING THAT EOR PROVIDE PLANS FOR CONDITIONS OTHER THAN HEREIN STATED, AND/OR RACKING OTHER THAN PCM, AND/OR INSTALLATION IN ROOF PRESSURE ZONES OTHER THAN PZ1 & PZ2, AND/OR TILT-UP GREATER THAN 15-DEGREES ABOVE THE ROOF PLANE, AND/OR INSTALLATIONS OUTSIDE OF US, AND/OR ELECTRICAL DESIGN, ARE REQUESTED TO CONTACT E0R DIRECTLY-OFFICE: 813 909 1956, E-MAIL: [email protected] STRUCTURAL: · SEISMIC - THIS PLAN IS EXEMPT IAW SUB-PARAGRAPH 6 OF ASCE 7-10 PARAGRAPH 13.1.4 · SNOW - SPECIFIED MATERIALS & METHODS ARE SUFFICIENTLY STRONG TO ACCOMODATE SNOW LOADS OF 10-PSF AND UNDER USING PCM RAIL ATTACHMENT SPACING SPECIFIED IN FIGURE 02. IN AREAS OF GREATER THAN 10-PSF GROUND SNOW LOAD AS DETERMINED BY ASCE 7 OR AHJ, USE SNOW & WIND COMBINATION RAIL-TO-ROOF ATTACHMENT SPACING TABLE WWW.GEZELMANPE.COM/GENERIC/PCM.WINDSNOW_US.HTM · WIND IS THE MAJOR STRUCTURAL CONSIDERATION FOR ROOF-MOUNTED SOLAR EQUIPMENT THERE SHALL BE TWO PCM RAILS EQUALLY-SPACED UNDER EVERY PV MODULE (ABOUT 25% IN). PV MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. PCM RAILS SHALL RUN PERPENDICULAR TO ROOF FRAMING. PCM RAILS SHALL BE ATTACHED TO ROOF FRAMING MEMBERS AT DISTANCES NGT (NOT GREATER THAN) CENTER-TO-CENTER DISTANCES SPECIFIED IN FIGURE 02. ROOF ATTACHMENT: AT EACH SPECIFIED ANCHOR POINT - A SINGLE CORROSION RESISTANT STEEL (CRS), 5/16” MINIMUM DIAMETER LAG, 3” LONG IS ACCEPTABLE AT WINDSPEEDS 150 OR LESS. ABOVE THAT, TWO LAGS ARE REQUIRED. A SINGLE, 3/8TH INCH DIAMETER, “J” BOLT IS ACCEPTABLE ANCHORAGE AT ALL WINDSPEEDS. PV MODULES SHALL ATTACH TO PCM RAILS AT EVERY CROSSING POINT WITH A GSAS MODULE CLAMP OR PCM CLAMP. ADJOINING MODULES MAY SHARE ATTACHMENT CLAMPS. S-5 CLAMPS SHALL BE USED ON STANDING SEAM MEATAL ROOFS IN CONJUNCTION WITH PCM RAILS RUNNING PERPENDICULAR TO STANDING SEAMS. RAIL TO STANDING SEAM CONNECTIONS SHALL BE MADE USING S-5 CLAMPS AT NGT 6-FT S-5 TO S-5 IN PZ1 AND NGT 4-FT S-5 TO S-5 IN PZ-2. WATERPROOFING; S-5 INSTALLATIONS INVOLVE NO ROOF PENETRATIONS. FOR OTHER ROOFS, LAGGING THRU A GENEROUS PUDDLE OF NOA/PCA (MIAMI-DADE/FLORIDA) APPROVED ROOFING SEALANT SHALL BE ADEQUATE. CONTRACTOR MAY, WITH APPROVAL OF AHJ, USE ALTERNATE MEANS & METHODS. CONTRACTOR SHALL ADHERE TO BEST PRACTICES/MEANS & METHODS OF ROOFING CHAPTER OF APPLICABLE BUILDING CODE AND NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT SYSTEM START-UP OR AS SYSTEM AGES. ANY FSEC CERTIFIED PV MODULE, LANDSCAPE OR PORTRAIT WWW.GEZELMANPE.COM/PV/0203P.PCM20_US.PDF (ON PAGE 2) "SAFE" ALL CASE (ALL WIND SPEED & ALL WIND EXPOSURE CATEGORY) SPACINGS: S5 PRODUCT CATALOG: VOID WITHOUT RAISED OR ELECTRONIC SEAL, MAY NOT BE USED FOR PLANS ON FILE, EVERY PERMIT PULLED REQUIRES A SEALED ELECTRONIC PLAN OR SEALED ORIGINAL PAPER COPY OF THIS PLAN ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 CALCULATED HOLD DOWN SPACINGS MAY BE SEEN AT: URL REFERENCES OEM, DATA SHEETS, INSTALLATION MANUALS HTTP://WWW.S-5.COM/GALLERY/INDEX.CFM HTTP://WWW.S-5.COM/COMMON/DOWNLOADS/PRODUCTCATALOG_073012.PDF • • • S5 CLAMP PROFILES: CLOUDED REVISION TO PROJECT 14-074 UNIVERSAL ENGINEERING SIENCES REVIEW FOR PV PERMIT. 11556 WILLOW GARDENS DRIVE, WINDERMERE, FL ROOF PRESSURE ZONE 1 (PZ1) 6 FT CENTER - TO - CENTER +- TO HIT FRAMING ROOF PRESSURE ZONE 2 (PZ2) 4 FT CENTER - TO - CENTER +- TO HIT FRAMING ROOF PRESSURE ZONE 3 (PZ3) 2 FT CENTER - TO - CENTER +- TO HIT FRAMING PH. 813 650 7246 TYP. RIDGE PZ3 PZ2 Allen@Gezelman PE.COM www.GezelmanPE.com PZ3 PROFESSIONAL ENGINEER WWW.GEZELMANPE.COM/LICENSE.HTML ITEM 1 DNA (DOES NOT APPLY) PCM PLAN SHEET IS FOR STRUCTURAL ONLY PORTION OF PROJECT. FSEC CERTIFICATION REQUIREMENT APPLIES ONLY TO ELECTRICAL DESIGN. PCM PLAN SHEET IS EXEMPT FROM FSEC REVIEW REQUIREMENT. WIND PRESSURE ZONE DIAGRAM: HTTP://WWW.GEZELMANPE.COM/REFERENCE/ASCE-7_PRESSUREZONES.PDF ITEM 2 PV. i CERTIFY THAT THE ROOF TRUSS SYSTEM OF SUBJECT BUILDING WILL WITHSTAND THE ADDED DEAD / GRAVITY LOAD IMPOSED BY PROPOSED ADDITION. WIND PRESSURE TABLES: SLOPE DN RAFTERS ROOF LENGTH HTTP://WWW.S-5.COM/CLAMPS/INDEX_1048.CFM PCM RAIL PZ1 PZ2 OFFSET "A" PCM RAIL PZ2 PER ASCE 7-10 FIG. 03 HTTP://WWW.GEZELMANPE.COM/GENERIC/WINDPRESSURE.HTM CALCULATED HOLD DOWN SPACINGS: WWW.GEZELMANPE.COM/PV/0328S.GS.WILLOWGARDENS_WINDERMERE_FL.PDF TYP. EAVE (PAGE 2) ROOF WIDTH REFERENCES REFERENCES ARE ACTIVE LINKS ON PDF VERSION OF THIS PRINT @ WWW.GEZELMANPE.COM/PV/0203P.PCM20_US.PDF 02 DESIGNED PER: ASCE 7-10,2010 IBC & STATE CODES BASED THEREON AHJ: ANY US JURISDICTION MODULE: FSEC, SRCC, CEC APPROVED PV MODULE HOLD DOWN SPACING SCALE: NTS 03 DESIGN WIND SPEED: 200 MPH EXPOSURE CATEGORY : D RISK CATEGORY: II CALCULATION: HTTP://WWW.GEZELMANPE.COM/GENERIC/WINDPRESSURE.HTM VERIFY 01 PZ3 PZ2 PZ3 WWW.GEZELMANPE.COM/PV/0203P.PCM20_US.PDF (ON PAGE 2) WIND JOHN DOE ANY LOCATION IN THE US I CERTIFY THAT PV INSTALLATIONS MADE IAW THIS PLAN CAN RESIST POSITIVE & NEGATIVE WIND FORCES PREDICTED IAW ASCE 7-10. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. I CERTIFY THIS DESIGN & SPECIFICATIONS MEET INTERNATIONAL BUILDING CODE (IBC)AND ALL STATE BUILDING CODES BASED UPON IBC –INCLUDING 2010 FLORIDA BUILDING CODE ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF THIS PLAN IS ONLINE FOR REVIEW @ CODE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE • • • COPY RIGHT & INTELLECTUAL PROPERTY NOTICE OWNER: SAMPLE ROOF LAYOUT PLAN SCALE: N.T.S. INSTALL ANY LOCATION IN THIS JURISDICTION CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THE PV ARRAY ON APPLICABLE ROOF SLOPE PRIOR TO INSTALLATION. CONTRACTOR SHALL CONTACT THE ENGINEER IF THE ARRAY MAY NOT FIT AS PROJECTED. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF THE PV ARRAY PRIOR TO INSTALLATION! ALUM CLAMP SYSTEM PV MODULE 1-1/4" SOLAR RAIL SYSTEM WATERPROOF WITH SONNOLASTIC NP-1 OR EQUAL POLYURETHANE CAULK STAR WASHER ROOF TILE, FLAT, BARREL ETC. MOUNTING RAIL RAILING PCM 2.5 X 0.75 RAILING 2.5 X 0.75 RAIL W/ CLAMP, L-SHAPED MIN 5 16"-INCH CR ANCHOR 3" EMBEDMENT RE: ENG. NOTES EXIST. SHEETING & MEMBRANE EXISTING RAFTER GSAS SOLAR CLAMP ARRAY ALUM CLAMPS PV MODULE SOLAR MOUNT RAIL 3 8 - 16 X 34 HEX HEAD BOLT 3/8-16 FLANGE BOLT C-C (RE: ENG NOTES) WATER PROOFING EXIST. ROOF ASP SHINGLE ROOF SERRATED L ROOF MOUNT RAIL CLAMP ON STANDOFF STANDOFF W / BASE STANDOFF EXIST. ROOF SHEETING GSAS SOLAR CLAMP ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/ 0328S.GS.WillowGardens_Windermere_FL.dwg GSAS END CLAMP 07 STAINLESS STEEL ELECTRICAL BONDING 'STAR' WASHER APPROVED ROOF ATTACHMENT W/ (GSAS) GEZELMAN SOLAR ANCHOR SYSTEM SCALE: NTS 3/8" CRS. BOLT, W/ MIN 3" THREAD EMBEDMENT IN BLOCKING, PURLIN,JOIST OR TRUST BLOCKING,TRUSS, RAFTER OR PURLIN SYSTEM: APPROVED PCM ROOF MOUNTING DETAILS 06 ANY JURISDICTION IN THE US ALUM L-FOOT GSAS SOLAR CLAMP, MID FIELD INSTALLATION OF A ROOF MOUNT 1-1/2" CONTACT DESIGN TEAM @ www.GezelmanPE.com L FOOT BRACKET LENGTH AS NEEDED PCM PRECISION AND S.L. PLOTA SCALE: 3" = 1'-0" 6203 80TH AVENUE N PINELLAS PARK FL 33781 USA GSAS CLAMP PV MODULE PV MODULE 3 3 8 - 16 X 4 HEX HEAD BOLT 3/8-16 FLANGE BOLT PV MODULE PV MODULE, MID CLAMP PV MODULE C-C (RE: ENG NOTES) S5 EXIST. STANDING SEAM METAL ROOF RAIL CLAMP 2.5", 3" PH. 727-547-6277 FAX 727-547-6279 SOLAR MOUNTING RAIL SOLAR MOUNTING RAIL SERRATED L ROOF MOUNT RAIL CLAMP 7" PZ1 6'-0" S5 PUBLISHED: REVISIONS: PZ2 4'-0" SET SCREW, TORQUE PER OEM PZ3 2'-0" EXIST. ROOF SHEETING S5 EXISTING TOP CHORD OF TRUSS / RAFTER C-C MAX. 24" 04 MODEL/APPEARANCE OF S-5 VARIES W/APPLICATION SEE S-5 FIG. 01 FOR REFERENCES S5 C-C MAX. 24" S5 C-C MAX. 24" APPROVED ROOF ATTACHMENT SYSTEM W/ S5 CLAMPS S5 CLAMP SYSTEM C-C SPAN DIAGRAM SCALE: NTS SCALE: NTS, APPROVED UNDER THIS PERMIT C-C MAX. 24" SHEET NAME: S5 DRAWN: SB PV MODULE , END CLAMP 05 RAIL SPLICE GROUNDING CLIP PCM RACKING COMPONENTS APPROVED UNDER THIS PERMIT SCALE: NTS SHEET NO: CHECKED: AG CALCULATED HOLD DOWN SPACINGS NOTICE TO AHJ, CONTRACTORS, OIP (OTHER INTERESTED PARTIES) THESE SPECIFICATIONS ARE PART & PARCEL OF MY SEALED PCM PV INSTALLATION PLANS SPECS MUST BE ON OR ACCOMPANIED BY SIGNED & SEALED PLAN TO BE VALID PCM 2.5 X 0.75 rail calculations 2010 FBC ASCE 7-10 mid collector height 20' or less roof pressure zone 1 all roof slopes design wind speed max. allow. c-c attachment inches exp B exp C exp D 200 64 56 51 190 67 59 54 180 71 62 57 175 HVHZ n/a 64 58 170 75 66 60 160 80 70 64 150 85 75 68 140 91 80 73 130 98 86 79 120 106 94 86 110 116 102 93 RAFTER CLIPS & 2"X4"X12" MIN BLOCKING IN LIEU OF ROOF FRAMING ATTACHMENT OK Use heavy bead liquid nails min 12" framing to sheeting joints bracketing blocking mid collector height 20' or less roof pressure zone 2 all roof slopes design wind speed max. allow. c-c attachment inches exp B exp C exp D 200 47 42 38 190 50 44 40 180 53 46 42 175 HVHZ n/a 48 43 170 56 49 45 160 59 52 48 150 63 56 51 140 68 60 54 130 73 64 59 120 79 70 64 110 86 76 68 RAFTER CLIPS & 2"X4"X12" MIN BLOCKING IN LIEU OF ROOF FRAMING ATTACHMENT OK Use heavy bead liquid nails min 12" framing to sheeting joints bracketing blocking INSTALLATION IN ROOF PRESSURE ZONE 3 REQUIRES SITE-SPECIFIC ENGINEERING PZ3 SHALL NOT BE USED IN HVHZ
© Copyright 2024