NEW R410A HIGH STATIC DUCTED RANGE 3 MODELS: CSU96HD, 150HD and 205 HD, single-phase indoor splits, 3-phase outdoor units • Multi diffusers from one indoor unit supply airflow to several rooms for applications such as restaurants, hotels etc. • Indoor airflow 5100 m3/h up to 10 800 m3/h • Eco-friendly R410A gas • External static pressure up to 196Pa • High-efficiency scroll compressor • Anti-corrosive hydrophilic heat exchanger fins • Backed nationwide by Alliance branches in every main metropolitan centre A/410Aducted20HP/0214 - LRES Alliance R410A High Static Ducted Range In response to public demand, Alliance now offers 3 R410A Ducted units for operation in temperatures of up to 46°C, matched with high static pressure indoor units. External static pressure of the indoor unit reaches up to 196Pa. A 3-phase outdoor unit has double direct-drive motors and axial fan for low noise levels, while heat exchanger fins are coated with anti-corrosive and hydrophilic layers to ensure long life. A multi-measurement system with self-diagnosis function, high pressure protection and temperature sensor on/off protection provides maximum reliability. An inspection port affords easy maintenance and a wired controller is standard. Duct-type units ensure flexible design Inspection port for easy maintenance S P E C I F I C AT I O N S INDOOR UNIT CSU-96HD Power supply Rated input (Indoor unit) Rated current (Indoor unit) Indoor air flow Indoor standard ESP Indoor noise level Refrigerant type Refrigerant pipe (Liquid/ Gas) Drain pipe size Dimension (W×H×D) Packing (W×H×D) Net/Gross weight V/Ph.Hz Btu/h W W W/W Btu/h W W W/W W A (m3/h/CFM) Pa dB(A) R410A mm mm mm mm kg Power supply Ambient temp in cooling Ambient temp in heating Rated input (Outdoor unit) Rated current (Outdoor unit) Noise level Type x Qty Capacity Input Rated current Locked rotor Amp Refrigerant oil Refrigerant type/charge Tube size Liquid side/ Gas side Max. pipe length Max. difference in level Dimension (W×H×D) Packing (W×H×D) Net/ Gross weight V-Ph-Hz °C °C W A dB(A) Scroll x3 15,390 5,130 8.8 62 500 (FVC68D) \ mm mm m m mm mm kg Capacity Cooling Heating Input EER Capacity Input COP OUTDOOR UNIT CSU-150HD 220-240V~, 1Ph, 50Hz 96,000 28,100 9,600 2.93 106,000 31,100 10,300 3.02 1,400 5.8 5,100 (3,000) 196 56 R410A 9.52/ 25 41 1,366×450×716 1,555×500×875 96/108 CSU-96HDN1X CSU-96HDX 380-415V~, 3Ph, 50Hz 17~46 -7~24 26,900 47.9 70 Scroll x 3 17,100 5,700 9.6 64 500 (FVC68D) R410A/10,000g 7 9.52/ 25 50 25m(O.D. up) /30m(O.D. down) 1,255×908×700 1,320×1,060×730 187/204 220-240V~, 1Ph, 50Hz 150,100 44,000 16,300 2.70 160,300 47,000 15,700 2.99 2,730 12.1 8,500 (5,000) 196 63 R410A 16/ 32 41 1,828×668×858 2,095×800×964 188/200 CSU-150HDN1X CSU-150HDX 380-415V~, 3Ph, 50Hz 17~46 -7~24 32,200 53.8 73 Scroll x 3 15,390 5,130 8.8 62 500 (FVC68D) R410A/11,800g 7.94 16/ 32 50 25m(O.D. up) /30m(O.D. down) 1,250×1,615×765 1,305×1,790×820 288/308 CSU-205HD 220-240V~, 1Ph, 50Hz 192,000 56,300 22,000 2.56 205,000 58,600 19,300 3.04 4,690 20.9 10,800 (6,354) 196 65 R410A 16/ 32 41 1,828×668×858 2,095×800×964 235/250 CSU-205HDN1X CSU-205HDX 380-415V~, 3Ph, 50Hz 17~46 -7~24 32,200 53.8 73 Scroll x 3 17,100 5,700 9.6 64 500 (FVC68D) R410A/11,800g 7.94 16/ 32 50 25m(O.D. up) /30m(O.D. down) 1,390×1,615×765 1,455×1,790×830 320/336 Alliance reserves the right to discontinue or change specifications or design at any time without notice and without incurring obligation Proudlydistributedby Gauteng: (011) 704-6320 Pretoria: (012) 643-0445 Bloemfontein: 083 381 0074 George: 082 380 0708 Cape Town: (021) 556-8292 KZN: (031) 579-1895 Port Elizabeth: (041) 484-6413 w w w. a l l i a n c e a i r. c o . z a
© Copyright 2024