TR002BA Training Package - Drager Merlin and PSS 7000 BA Set Q

Merlin Telemetry Board
and
Dräger PSS 7000
Q&A
Question - 1
What is the function of the first stage reducer on
the PSS 7000t BA set ?
A - It reduces the air from cylinder pressure to between 6 – 9 bars.
B - It reduces the air from cylinder pressure to just above atmospheric pressure.
C - It reduces the air from cylinder pressure to between 11 – 16 bars.
D - It reduces the air from between 6 – 9 bars to just above atmospheric pressure.
PREVIOUS
NEXT
Question - 2
Following a full charge, how long will the battery last in
the Dräger Bodyguard 7000t unit?
A - Approximately 1 hour..
B - Approximately 8 hours.
C - 100 hours.
D - 5 – 6 hours.
PREVIOUS
NEXT
Question - 3
What is the lifespan of a Dräger 9 litre, 300 bar
compressed air cylinder ?
A - 5 years.
B - 10 years.
C - 15 years.
D - 20 years.
PREVIOUS
NEXT
Question - 4
On the Dräger Merlin Telemetry Entry Control Board,
what does the following LED indicate ?
A - Emergency Voluntary Withdrawal has been actuated.
B - Automatic Distress Signal Unit has been actuated.
C - Evacuation signal has been actuated.
D - Manual Distress Signal Unit has been actuated.
PREVIOUS
NEXT
Question - 5
On the Dräger Merlin Telemetry Entry Control Board,
what does the following LED indicate ?
A – Manual Distress Signal Unit has been actuated.
B - Emergency Voluntary Withdrawal has been actuated.
C - Telemetry link has been lost.
D - Automatic Distress Signal Unit has been actuated.
PREVIOUS
NEXT
Question - 6
How often does the telemetry link update/refresh
between the Bodyguard 7000t and the Merlin
Telemetry Board ?
A - Every 20 seconds.
B - Every second.
C - Whenever there is a change in air consumption/breathing rate.
D - Every minute.
PREVIOUS
NEXT
Question - 7
When does the pneumatic low pressure warning
whistle sound on the Dräger PSS 7000t BA set ?
A-
Between 70 and 60 bars.
B-
Between 45 - 40 bar.
C-
Between 60 +/- 5 bars.
D-
Between 6 – 9 bars.
PREVIOUS
NEXT
Question - 8
What would be the outcome of pressing this
button on the Merlin Telemetry Board ?
A - All BA wearers committed from that ECB will receive an evacuation signal.
B - All BA wearers in the area will receive an evacuation signal.
C - It will evacuate an individual wearer.
D - It will reset the clock.
PREVIOUS
NEXT
Question - 9
What do these flashing LEDs signify ?
A-
Signal lost between EMU & Telemetry Board.
B-
EMU in operation.
C-
EMU in operation & linked to Telemetry Board.
D-
Distress signal activated.
PREVIOUS
NEXT
Question - 10
What do the RED flashing LEDs signify ?
A-
Signal lost between EMU & Telemetry Board.
B-
EMU in operation.
C-
EMU in operation & linked to Telemetry Board.
D-
Units Distress signal activated.
PREVIOUS
NEXT
Question - 11
What is the minimum cylinder content required
for a Re-Entry using a 9litre, 300 bar cylinder ?
A - 160 bars.
B - 150 bars.
C - 170 bars.
D - 100 bars.
PREVIOUS
NEXT
Question - 12
What does this figure represent on the Dräger
Bodyguard 7000t display screen ?
A - Time to whistle.
B - Time of whistle.
C - Elapsed time of BA wear.
D - Remaining cylinder contents.
PREVIOUS
NEXT
Question - 13
What does this figure represent on the Dräger
Bodyguard 7000t display screen ?
A - Time to whistle.
B - Time of whistle.
C - Elapsed time of BA wear.
D - Remaining cylinder contents.
PREVIOUS
NEXT
Question - 14
On the Dräger Bodyguard 7000t, what is the
meaning of the following icon on the display ?
A - The evacuation signal has been actuated by the ECO.
B - The Emergency Voluntary Withdrawal has been actuated by the BA wearer.
C -The Automatic Distress Signal has been actuated.
D - The telemetry link has been lost between the Bodyguard and the Merlin ECB.
PREVIOUS
NEXT
Question - 15
On the Dräger Merlin Telemetry Entry Control
Board, what does this flashing LED indicate ?
A - Telemetry board is shutting down.
B - Automatic Distress Signal Unit has been actuated.
C - Evacuation signal has been actuated for an individual wearer.
D - Emergency Voluntary Evacuation has been actuated.
PREVIOUS
NEXT
Question - 16
What period of time does the Dräger Merlin
Telemetry Entry Control Board log past
activities for ?
A - The last 100 hours.
B - The last 5 – 6 hours.
C - 10 hours.
D - 8 hours.
PREVIOUS
NEXT
Question - 17
Which of the following is the correct shutting
down procedure ?
A-B-C
A - Airway , Breathing , Circulation.
B - Air supply , Bodyguard , Comms.
C - Air supply , Battery , Cylinder.
D - Air supply , Battery , Comms.
PREVIOUS
NEXT
Question - 18
After what time period will the Pre- Alarm
sound if the motion sensor detects
No movement ?
A - 45 - 40 seconds
B - 10 seconds
C - 30 seconds
D-
8 -10 seconds
PREVIOUS
NEXT
Question - 19
After the Pre- Alarm has been activated how long
will it be before
FULL ALARM
is activated if no further movement is detected ?
A-
30 seconds
B-
10 seconds
C-
5 -10 seconds
D-
45 -40 seconds
PREVIOUS
FINISH
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
CORRECT
CLICK ICON FOR NEXT QUESTION
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
WRONG
CLICK ICON TO RETURN
CORRECT
CLICK ICON FOR NEXT QUESTION
WRONG
CLICK ICON TO RETURN
YOU HAVE COMPLETED ALL THE QUESTIONS
CORRECT
WRONG
CLICK ICON TO RETURN