How to Reboot or Power Down a Splicecom Maximiser 4140 Callserver
Please follow the guide below for instructions on how to reboot or power down a Splicecom
Maximiser 4140 Callserver.
Reset Switch
The Reset Switch on the front of a module can be used to assist with
h troubleshooting the
SpliceCom system.
The image below is what a 4140 callserver looks like. Note the location of the reset switch next
to the last POT port on the left hand side of the unit.
unit. To perform a reboot the customer will
require a paperclip
clip (or ear ring).
Reboot (Warm Start)
Reset switch
A reboot of a module may be required to restore connection to the LAN, restore connection to
the Call Server etc.
1.
2.
3.
4.
5.
Press the Reset Switch once. (push the paperclip into the reset switch and release)
The file system will start to shut down
After about 10 seconds the LEDs on the front of the Call Server will flash and turn off
The SpliceCom LED will flash slowly to indicate that the shut down is complete.
When the SpliceCom LED is flashing pres
presss the Reset Switch once (or no more than 3
times).
6. The LED will turn off for 10 seconds and then flash rapidly as the system restarts.
Alternatively wait for 60 seconds the module will automatically restart.
Orderly Shutdown
down of the File System
It is important
ant to shut down the file system within the Call Server before removing power.
1.
2.
3.
4.
5.
Press the Reset Switch once.
The file system will start to shut down
After about 10 seconds the LEDs on the front of the Call Server will flash and turn off
The SpliceCom LED willll flash slowly to indicate that the shut down is complete.
At this point the power can be removed.